Using electronic Sensor technology, accuracy of +/- 0.5%, resolution of 0.1N.m, support two-way verification and automatic conversion of three units, provide standard test forms and custom test items.
Using Electronic Sensor technology, accuracy of +/- 0.5%, resolution of 0.01N.m, support two-way verification and automatic conversion of three units, test interface real-time display Indication Error and repeability.
Electronic Sensor technology, accuracy of +/- 0.5%, resolution of 0.1N.m, support two-way verification and three units of automatic conversion, can customize test items and check points, real-time display error and repeability.
With 50N.m range and +/- 0.5% accuracy, it supports two-way verification and 8 custom check points, provides real-time error display and a variety of unit automatic conversion functions.
Electronic Sensor technology, range 1000N.m, resolution 0.1N.m, support two-way verification and three units of automatic conversion, can customize 10 test items 8 check points, real-time display error and Repeatability.
With +/- 0.5% accuracy and 0.01N.m resolution, support two-way verification and 8 custom test points, real-time display of Indication Error and repeability, easy and stable operation.
Range 2000N.m, indication relative error ≤ +/- 1%, with two-way verification function, support three units automatic conversion, can customize 10 test items and 8 check points, real-time display error and Repeatability data.
With 5000N.m range and +/- 1% indication relative error, support two-way verification and automatic conversion of three units, provide standard test form and custom test item function.
Range 3000N.m, indication relative error ≤ +/- 1%, support two-way verification and 8 checkpoint customization, equipped with 7-inch Touchscreen real-time display test data and error analysis.
Electronic Sensor technology, accuracy of +/- 0.5%, resolution of 0.001N.m, support two-way verification and real-time data display, can customize test points and print results directly.
Frequency 159.2Hz, Acceleration output 10m/s ², Support 150g load verification, Transverse output less than 5%, Heating time less than 3 seconds, Compact handheld design for fast detection.
Temperature range 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, using forced convection design to heat up quickly, over-temperature automatic interruption operation to ensure safety, shelf can be moved for easy cleaning.
Temperature range RT + 10~ 200 ℃ and resolution up to 0.1 ℃, forced convection design to shorten the rapid heating drying time, with over-temperature automatic protection and fan speed regulation function, shelf can be moved for easy cleaning and maintenance.
High Accuracy microcomputer temperature controller, temperature control accuracy of +/- 1 ℃, Temperature resolution of 0.1 ℃; forced convection design makes rapid heating, drying and disinfection time shortened; with over-temperature automatic interruption function to ensure safe operation.
Adopt the principle of high temperature dry heat disinfection, destroy the protoplasm of microbial cells by oxidation, Temperature range 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, with forced convection, three-speed fan speed regulation and timing functions to ensure efficient and safe disinfection.