Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with 100 sets of programmable control, support color Touchscreen operation and remote monitoring function, built-in multiple Safety protection system.
Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, equipped with independent temperature limit alarm system, support multi-stage programmable control, easy to automate the operation of complex test process.
Temperature range -60~ 150 ℃ and Humidity control 30~ 95% R.H., equipped with fluorine-free environmental protection refrigeration system; color Touchscreen supports multi-stage programming, with independent alarm and multiple Safety protection functions.
Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, Humidity deviation +/- 3% RH, with multi-stage programmable control and multiple Safety protection functions.
Using fluorine-free environmental protection refrigerant and imported Compressor, Temperature range -20~ 150 ℃, humidity control 30~ 95% R.H., with independent temperature limit alarm and multiple Safety protection functions, support multi-stage programmable control.
Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control and independent temperature limit alarm system, support data export function.
The use of high temperature resistant fiberglass insulation material wOven into a hemispherical internal heating heater, heating area and heating fast, the highest temperature of 380 ℃, good insulation effect and no open flame, to avoid bruising Glass ware.
Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control function, support 100 sets of program settings, equipped with independent temperature limit alarm system to ensure safe operation.
Six synchronous Stir design can process multiple samples at the same time, using electronic temperature control technology implementation RT +~ 100 ℃ accurate temperature control, stirring speed 0~ 2000rpm to meet the needs of different viscosity liquids, DC motor to ensure smooth operation without vibration.
Using fluorine-free environmental protection refrigerant and imported Compressor, Temperature range -40~ 130 ℃, uniformity +/- 2 ℃, with 120 sets of programming and multiple Safety protection systems, support data communication and real-time monitoring.
Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, equipped with independent temperature limit alarm system and multi-function programmable controller, support data export and remote monitoring function.
Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, equipped with programmable Touchscreen controller, supports multi-stage program control and real-time data monitoring to ensure stable and reliable testing process.
304 stainless steel one-time stretching liner has no water leakage, the four-corner arc design is heated evenly, the temperature fluctuation is +/- 0.5 ℃, the six-hole configuration meets various experimental needs, and the hidden outlet pipe is easy to operate.
Temperature range -40~ 130 ℃, Temperature Uniformity +/- 2 ℃, using fluorine-free environmental protection refrigerant and imported Compressor, with 120 groups of programmable control and independent temperature limit alarm system, support Interface for easy monitoring.
Temperature range -40~ 130 ℃ and uniformity +/- 2 ℃, using fluorine-free environmental protection refrigeration system, equipped with multi-stage programmable control and independent temperature limit alarm function to ensure the safety and stability of the experimental process.