Chilled Water Bath Tank

Cold water baths cool water through a refrigeration system and maintain a constant low temperature, which is used for cooling laboratory samples, controlling reaction temperatures, or cooling equipment. They are commonly used in chemical synthesis, material testing, and biological experiments.
Selection
When selecting, consider the temperature range and stability, capacity matching the sample size, cooling power meeting the cooling speed, material corrosion resistance, simplicity of the operation interface, and maintenance requirements, in combination with the practical application environment and budget.

Terms

Standards

Instruments

Water Bath, water temperature box and boiling disinfection box three functions, Temperature range from room temperature to 100 ℃, Tank size 42 * 18 * 20cm, to meet a variety of experimental heating and disinfection needs.

$ 180.00

With three uses of water Bath, thermostatic and boiling disinfection, Temperature range RT +~ 100 ℃, Tank volume 36L, suitable for a variety of experimental heating and equipment processing needs.

$ 209.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Integrated Air-Cooled circulation device, cooling capacity 3600W, temperature control range of 5~ 35 ℃, with water shortage, temperature, water pressure and overheating and overcurrent multiple Safety protection functions.

$ 2037.00

Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.

$ 493.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

Double-decked serpentine coil design, chilled down area of 0.15 m2, maximum evaporation capacity of 22ml/min, support water Bath and oil Bath double heating mode, sealing system using high resilience PTFE material, high temperature corrosion resistance.

$ 1074.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

Temperature range -10 ℃, Tank volume 10L, using fully enclosed Compressor unit and circulating water pump, energy saving and prevent scaling pollution of circulating water, protect the normal operation of the instrument.

$ 1379.00

The equipment has a 15-liter large-capacity water Tank and an 8mm inner diaMeter water pipe, supports 0 to 99 hours of time control, adopts stainless steel structure and automatic control device, and is suitable for coating stain resistance testing.

$ 369.00

Stainless steel liner is used to ensure durability, microcomputer program control to achieve accurate temperature control, Temperature Fluctuation +/- 0.5 ℃, multi-stage program can be preset to simplify complex experiments, support internal and external circulation and over-temperature alarm to protect samples.

$ 393.00

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, Temperature control accuracy 0.01 ℃, Built-in High Accuracy PT100 Sensor, support external circulation and domestic circulation system, ensure that the flow field and temperature field in the Tank are highly uniform.

$ 869.00

Articles

The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.
Both thermal shock test chambers and temperature cycling test chambers are used to test the temperature resistance of products, but their core differences lie in the method and purpose of temperature change.
Technical Differences Between Two-Chamber and Three-Chamber Thermal Shock Test Chambers
The thermal shock test chamber is used to test a product's resistance to sudden temperature changes, primarily through two methods: the two-chamber method and the three-chamber method. What are the differences between them? This article will tell you!
Condensation test chamber simulates the impact of humid environments on coatings.
This article introduces how a condensation test chamber simulates humid environments to test coating performance. It generates steam by heating water and cools the sample surface to form a condensation film.
5 Common Misconceptions in Selecting a Freeze Dryer: If Your Samples Are Damaged, You Probably Didn't Read This Article
Are you aware of the five common misconceptions when selecting a freeze dryer? This article highlights several pitfalls to help you avoid them.
The difference between thermal shock test chambers and constant temperature and humidity chambers
This article compares the differences between thermal shock test chambers and constant temperature and humidity chambers in terms of working principles, key performance, and applications.