Using open ceramic core liquid complex design, with solid polymer reference system, Measurement range 0~ 14pH, Temperature range 0~ 80 ℃, Membrane Impedance lower than 250MΩ, to ensure Stability and long life.
With open liquid network design, equipped with solid polymer reference system, Measurement range 0-14pH, Temperature range 0-80 ℃, to ensure long-term Stability and anti-pollution ability.
Using open liquid complex structure, equipped with solid polymer reference electrolysis solution, the membrane resistance is less than 200MΩ, suitable for -5~ 80 ℃ wide temperature environment, to ensure long-term stable measurement.
Open + ceramic core liquid complex design, equipped with solid polymer reference electrolysis solution, membrane Impedance below 250MΩ, Measurement range covering 0~ 14pH, temperature adaptability 0~ 80 ℃, to ensure long-term Stability and Fast Response.
It is designed with an open liquid complex combined with a ceramic core, equipped with a solid polymer reference electrolysis solution, and the membrane Impedance is less than 250MΩ. It has long life characteristics and a wide temperature range of 0-80 ° C.
It adopts the combination design of open liquid network part and ceramic core, equipped with solid polymer reference electrolysis solution, the membrane Impedance is lower than 250MΩ, and the shell is made of titanium alloy, which is suitable for 0-80 ℃ temperature environment.
Equipped with 7-inch Touchscreen, easy to operate, support stepless speed measurement and viscosity automatic conversion, measurement range 1~ 75000000mPa.s, gigabit network port to ensure fast and reliable data transmission.
The shear rate is 5.0N, the sample volume is only 170μL, the applicable viscosity range is 50~ 100000mPa · s, suitable for a variety of fluid measurement, high measurement accuracy.
Equipped with 7-inch Touchscreen operation interface, supports high-speed data transmission of gigabit network port, measurement accuracy of +/- 2%, temperature control accuracy +/- 0.1 ℃, with automatic lifting and anti-static design.
The shear rate is 13.3N, the sample volume is only 67 μL, the applicable viscosity range is 20~ 37500mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid tests.
Measurement range 0-14pH, temperature tolerance 0-80 ℃, with long life reference and low film resistance characteristics.
The shear rate is 13.3N, the sample volume is only 38μL, the applicable viscosity range is 37~ 75000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for testing various fluid samples.
The shear rate is 3.3N, the sample volume is only 30μL, and the viscosity range is 750~ 1500000mPa · s, which is suitable for accurate measurement of medium viscosity to high viscosity fluids.
The rotor shear rate is 3.3N, the sample volume is only 67 μL, the applicable viscosity range is 300~ 600000mPa · s, and the accuracy is +/- 2% F. S, which is suitable for a variety of fluid testing needs.
Measurement principle using ultrasonic, Measurement range 13~ 1000μm, accuracy +/- (2μm + 3%), suitable for wood, plastic and other substrates polymer Coating thickness detection.