UV-Visible Light SpectroPhotoMeter

UV spectrophotometers utilize the absorption characteristics of substances to ultraviolet light, analyzing component concentrations by measuring sample absorbance. They are used to detect dye content in paints and inks, plastic additive concentrations, and water quality pollutants.
Selection
When selecting, consider a wavelength range covering 190-1100nm, match the cuvette material with the sample type, ensure the detection limit meets industry standards, and verify instrument stability through warm-up time and environmental adaptability.

Terms

Standards

Instruments

1200L/mm UV dedicated grating and proportional double beam of light design, stray light ≤ 0.03% T, equipped with 10cm sample holder and automatic octet cell, support wavelength scanning and a variety of test modes.

$ 3623.00

1200L/mm UV dedicated grating and proportional double beam of light design, Wavelength range 190~ 1100nm, stray light ≤ 0.03% T, support automatic correction of wavelength error and a variety of test functions to ensure High Accuracy and Long-term Stability.

$ 2494.00

Adopt 1200L/mm UV special grating and imported photoelectric converter, stray light ≤ 0.03% T, Wavelength range 190~ 1100nm, with automatic correction wavelength error function, support 10cm sample holder to meet special needs.

$ 2252.00

1200L/mm UV dedicated grating ensures low stray light and high resolution, proportional dual beam of light design supports a variety of test functions, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, Wavelength range 190~ 1100nm.

$ 4592.00

1200L/mm UV dedicated grating to ensure low stray light and high resolution, proportional double beam of light design with automatic octagonal cell sample holder to improve test efficiency, Wavelength range 190~ 1100nm coverage of a wide range of applications.

$ 3268.00

1200L/mm High Accuracy Grating and proportional dual beam of light paths, stray light as low as 0.03% T, equipped with automatic octagonal cell sample holder and 7-inch Touchscreen, support multi-wavelength and kinetic testing.

$ 2494.00

1200L/mm UV dedicated grating to ensure low stray light and high resolution, proportional double beam of light design with automatic octave cell sample holder to improve test efficiency, with automatic wavelength correction function and a variety of test modes.

$ 3268.00

Using Czerny-Turner optical path to ensure linear Precision and ultra-low stray light, Light spectrum Bandwidth 1.8nm, can store 100 standard Linear dispersion and 200 data, support a variety of Cuvette and direct printouts.

$ 1300.00

Proportional double beam of light monitoring and Holographic grating, wavelength Precision +/- 0.5nm, stray light ≤ 0.15% T, support automatic zero adjustment and eight Sample Chamber linkage, easy and reliable operation.

$ 2252.00

Using Czerny-Turner optical path to ensure detection of linear Precision and ultra-low stray light, Light spectrum Bandwidth 2nm, can store 100 standard Linear dispersion and 200 data, supports a variety of Cuvette and direct printouts.

$ 1300.00

1200L/mm UV dedicated grating to ensure low stray light and high resolution, proportional dual beam of light design supports automatic octet cell, Wavelength range 190~ 1100nm, with professional wavelength correction function.

$ 2978.00

Proportional double beam of light path and Holographic grating, stray light ≤ 0.15% T, Wavelength range 190~ 1100nm, support automatic zero adjustment and eight Sample Chamber linkage, with professional power-off protection function.

$ 2591.00

Dual beam of light path structure and 1600L/mm high performance grating, Wavelength range 190-1100nm, stray light ≤ 0.03% T, equipped with color Touchscreen and Automatic calibration function, support a variety of Data analysis and map processing operations.

$ 5237.00

Adopt standard double beam of light path structure, equipped with 1600L/mm high performance holographic blazing grating, wavelength Precision +/- 0.3nm, stray light ≤ 0.03% T, with Automatic calibration wavelength error function, support a variety of data map processing.

$ 4914.00

Adopt standard double beam of light path structure, equipped with 1600L/mm high performance holographic blazing grating and imported photoelectric converter, wavelength Precision +/- 0.5nm, stray light ≤ 0.03% T, with Automatic calibration wavelength error function.

$ 4592.00

Articles

Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
The role of spectrophotometers in ink color matching
The spectrophotometer objectively quantifies color by measuring the spectral data of ink. Based on the Lambert-Beer law, it converts color into calculable spectral values, replacing traditional methods that rely on the human eye and experience.
Application of UV Spectrophotometer in the Determination of Lignin in Pulp
This article introduces the application of ultraviolet spectrophotometry in determining the lignin content in pulp. Lignin is a key component affecting pulp quality. This method utilizes the characteristic absorption of lignin under ultraviolet light for measurement, offering simple and rapid operation.
Determination of Chromaticity Value of Pulp by Spectrophotometry
This article introduces the method for determining pulp chromaticity using spectrophotometry. It first explains the importance of chromaticity for pulp quality, then details the basic principles of spectrophotometry, which quantifies color by measuring the reflection of light from the pulp, typically expressed using the CIELAB color system.
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
Application of Spectrophotometry in Heavy Metal Detection
A spectrophotometer detects heavy metal concentrations by utilizing the absorption of light at specific wavelengths by substances, following the principle of the Lambert-Beer law. During detection, heavy metal ions react with chromogenic agents to form colored complexes, and the concentration is determined by measuring absorbance and comparing it against a standard calibration curve.
Guide to Avoiding Pitfalls When Purchasing a Spectrophotometer
When selecting a spectrophotometer, it is essential to first understand its working principle based on the Lambert-Beer law, as this helps in assessing the rationality of the instrument's design.