Liquid Heating Stirrer

Liquid heating stirrers heat the liquid inside a container through electric heating elements, while a motor drives the stirring paddle to rotate for mixing. They are used for operations such as sample dissolution, reaction acceleration, and temperature homogenization in laboratories. They are commonly employed in sample pretreatment processes in the chemical, food, and pharmaceutical industries.
Selection
Select a motor with corresponding torque based on sample viscosity, match heating power according to temperature range, and choose contact materials considering corrosion resistance. The shape of the stirring paddle should be compatible with the container structure, speed adjustment should cover experimental needs, and safety features should include overheat protection and insulation design.

Terms

Standards

Instruments

Heating power 800W, speed range 0-2600 rpm, support vacuum reaction and pressure reaction for a long time stirring, with durable magnetic steel and PTFE stirrer.

$ 209.00

DC brushless motor design, Rotation speed 0~ 2000rpm, put in the stirrer without hopper; double-decked thermal insulation structure, rapid heating and prolong the life of the host; built-in over-temperature protection device, safe and reliable use.

$ 222.00

Maximum heating temperature 400 ° C, stirring speed 0~ 1250rpm, support external temperature sensor automatic thermostatic, key Rotation speed setting to prevent stirringRod stall, large screen LCD display temperature and stirring status.

$ 259.00

Temperature range environment to 380 ℃, can work continuously, large heating area and rapid heating, effectively protect Glass ware.

$ 140.00

Driven by brushless DC motor, with 25mN · M torque and 0~ 2000rpm speed range, Heating power adjustable within 800W, support automatic temperature control function, suitable for stirring of high viscosity liquids.

$ 273.00

Using high temperature non-alkali fiberglass insulation material, the highest temperature 380 ℃, with internal and external dual Sensor temperature measurement function, large heating area and rapid heating, excellent thermal insulation effect.

$ 151.00

Single chip microcomputer control to achieve digital settings, with heating plate and liquid temperature double automatic temperature control, temperature control accuracy +/- 1 ℃, Max.stirring Capacity 10L, Speed range to 1500rpm, support 0-250 minutes timing.

$ 349.00

Maximum temperature up to 400 ℃, temperature control accuracy +/- 0.2 ℃, DC brushless motor running smoothly low noise, aluminum die-casting ceramic coating work plate abrasion resistance corrosion resistance, double heating control circuit to improve Stability.

$ 509.00

Using infrared heating technology, the heating speed reaches 5 ℃/sec, Temperature uniformity 1-3 ℃, supports internal and external temperature sensor switching, equipped with 6 independent stations, Max. stirring Capacity 18L, DC motor runs smoothly.

$ 1663.00

Temperature range environment temperature to 380 ℃, can work continuously. The surface temperature of the heating element is up to 380 ℃, and the insulating layer is wOven with high temperature resistant fiberglass without alkali.

$ 117.00

Temperature range environment temperature to 380 ℃, can work continuously, heating element surface temperature up to 380 ℃, insulation layer sealing resistance wire design is safe and reliable.

$ 110.00

Temperature range environment temperature to 380 ℃, can work continuously, the maximum temperature of the surface of the heating element is 380 ℃, and the sealing design of the insulating layer ensures the safety of use.

$ 114.00

Double station synchronous operation, heating power 150W × 2, Temperature range RT +~ 100 ℃, using DC motor to ensure no noise and no vibration, fast IT single chip microcomputer to achieve accurate speed control.

$ 128.00

Adopting high temperature resistant non-alkali fiberglass insulation material, the maximum operating temperature is 380 ℃, with internal and external dual Sensor temperature measurement function, large heating area and no open flame design.

$ 143.00

Adopt electronic voltage regulation circuit without electric shock, Temperature range environment temperature to 380 ℃, can work continuously, large heating area and no open flame design, avoid bumping Glass ware.

$ 123.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
The oral dissolving film is uniformly coated by a film applicator and then dried and formed.
Oral dissolving films are prepared by a coating mechanism, where a liquid containing film-forming materials is uniformly applied onto a substrate, followed by drying to remove the solvent and form a solid film.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Surface Tensiometer Evaluates the Wetting and Spreading Properties of Resin Liquids
This article introduces how to use a surface tensiometer to evaluate the wetting and spreading performance of resin liquids. Wetting and spreading affect the adhesion and appearance of products such as coatings and adhesives, and the process can be described by Young's equation and the spreading coefficient.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
Application of Paper Absorbency Tester in Sizing Process
The paper absorbency tester evaluates the absorption performance of paper by measuring the penetration of liquid on the paper. In the sizing process, sizing agents alter the hydrophilicity of the paper fiber surface, thereby affecting the paper's resistance to liquids.
Water Absorption Tester in the Detection of Tissue Paper and Paperboard
This article introduces the application of water absorption testers in the testing of tissue paper and paperboard. The instrument evaluates the water absorption performance of materials by measuring the mass or height of liquid absorbed by the sample, with common methods including the Klemn method and the capillary rise height method.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
Surface Tensiometer: Interpreting the Invisible Forces on Liquid Surfaces
Surface tension is the contractile force generated by the uneven forces acting on molecules at the liquid surface, influencing phenomena such as droplet formation and capillarity. Surface tension meters measure this force using techniques like the Wilhelmy plate method, the platinum ring method, or the pendant drop method. Their core components include force sensors, sample stages, and data processing systems.