Magnetic Rod Scraping Sample Table

The magnetic rod coating table uses magnetic force to secure a steel rod, which evenly spreads the coating material over the substrate at a constant speed to form a uniform wet film. It is used in laboratories to simulate printing and coating processes, as well as to test properties such as the hiding power and leveling of the coating.

Instruments

Using 160 * 280mm size, with wire Rod scraping ink to ensure that the film is flat, Glass table is conducive to operation and observation effect.

$ 112.00

Spreader movement driven by electric push Rod, adjustable speed range of 2-200mm/s, equipped with Vacuum chuck table to effectively fix the substrate, Operating interface intuitively simplifies the process, improves Spreader accuracy and efficiency.

$ 2010.00

The table temperature adjustment technology is used to effectively suppress temperature overshoot, the temperature control accuracy reaches +/- 1 ℃, and supports four-station synchronous operation, Max. stirring Capacity 5L × 4, Speed range 100-1600rpm.

$ 724.00

Adopt scraping and dipping process, effective application width 300mm, Temperature control accuracy +/- 3 ℃, mechanical speed 0.1-1 m/min adjustable, equipped with magnetic particle brake and tension controller to achieve automatic tension control, suitable for a variety of Coatings.

$ 10562.00

Glass material is conducive to film flatness, size 230 * 340mm, with wire Rod or Film Applicator for scraping operation is more effective.

$ 115.00

Using 180 * 480mm size, with wire Rod or Film Applicator scraping ink, is conducive to the film flat and effective, improve film mass.

$ 122.00

Adopting 500 * 700mm Dimensions, used with bar or Film Applicator, is conducive to the smooth and effective film, and improves the convenience of film operation.

$ 227.00

Formed pRoduction process to ensure uniform film, wet film thickness 82.3 μ m precise control, stainless steel wear-resistant and durable, application width 300mm to meet a variety of experimental needs.

$ 167.00

The scraping speed is adjustable from 10-100mm/s, and the drawdown blade load 1.75-6 kg is adjustable. It is used with High Accuracy GrindoMeter to avoid personnel operation errors and improve test conformity.

$ 1364.00

Using formed pRoduction process, wet film thickness 34.3μm, application width 300mm, stainless steel material is durable and easy to clean, suitable for a variety of inks scraping applications.

$ 167.00

The equipment adopts scraping method, coating speed 1~ 10m/min, thickness range 0.005-3mm, equipped with automatic deviation correction and tension control to ensure uniform and stable Spreader.

$ 24279.00

Temperature control accuracy of +/- 1 ℃, Max. stirring Capacity 10L, table temperature setting technology effectively inhibits heating overshoot phenomenon, supports Continuous Operating Mode.

$ 320.00

Glass material ensures that the film is flat, used with wire Rod or Film Applicator, the specification size is 110 * 180mm, and the operation is simple and efficient.

$ 106.00

Adopt scraping method, coating speed 1-10m/min adjustable, Spreader thickness range 0.005-3mm, drying tunnel temperature up to 200 ℃, equipped with adjustable drawdown blade device and thickness adjustment dial Meter to achieve precise control.

$ 24279.00

Adopt scraping method, coating speed 1-10m/min adjustable, Spreader thickness range 0.005-3mm, equipped with drying tunnel temperature RT + -200 ℃ and automatic deviation correction device to ensure uniform and stable Spreader.

$ 21051.00

Articles

Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
The heating film coater applies thick-film resistor paste onto the ceramic substrate.
The heating coating machine is used to apply thick film resistor paste on ceramic substrates. It reduces the viscosity of the paste through a heating platform and ensures uniform coating in conjunction with the coating head.
Vacuum adsorption coating table solves the problem of film substrate wrinkling.
The vacuum adsorption coating platform uses a microporous array connected to a vacuum system beneath the tabletop to create a pressure difference, tightly adsorbing the film substrate. This ensures it remains flat during the coating process, preventing wrinkles that could lead to uneven coating.
How to Utilize a Vacuum Adsorption Coating Machine to Solve the Slippage Issue During Coating on Flexible PET Substrates
The vacuum adsorption coating machine stabilizes the flexible PET substrate on the coating platform through negative pressure, effectively addressing the slipping issue during the coating process. Slipping is primarily caused by factors such as the smooth surface of PET, insufficient friction, and interference from coating pressure, which can lead to uneven coatings.
Effect of Platform Temperature on Surface Drying Time of Waterborne Polyurethane Coatings in Heated Automatic Film Applicators
This study investigates the influence of the platform temperature of a heated automatic film applicator on the surface drying time of waterborne polyurethane coatings. The experiments reveal that as the platform temperature increases, the surface drying time of the coating significantly decreases, showing a negative correlation between the two.
Vibration test bench simulates transport packaging environment testing.
Vibration testing tables simulate the vibration environment during transportation in the laboratory to test packaging and evaluate its protective performance. The tests primarily follow domestic and international standards, simulating sinusoidal or random vibrations that cover typical transportation conditions such as road and rail.
Performance Comparison and Selection Guide Between Electric Vibration Tables and Hydraulic Vibration Tables
Electric shakers and hydraulic shakers are two commonly used vibration testing devices, each with different working principles. When selecting a model, factors such as test frequency, specimen weight, displacement requirements, and cost need to be considered.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
Selection Guide How to Choose a Vibration Test Bench Based on Testing Standards
When selecting a vibration test system, start by carefully reviewing the test standards to clarify key parameters such as frequency range, thrust force, displacement, acceleration, and vibration type. Then, based on the standard requirements, calculate the required thrust force, match the specifications of the shaker and amplifier, and select an appropriate control system.
Key Points for Operating Vacuum Adsorption Coating Machines on Flexible Substrates
Vacuum adsorption coating technology is a key process in flexible electronics, functional coatings, and the preparation of new materials. This technique uses vacuum negative pressure to ensure that flexible substrates are smoothly and evenly adsorbed onto the coating platform. Combined with precision coating, it effectively reduces defects such as wrinkles and bubbles, thereby enhancing the uniformity and consistency of the coating.
Detailed Explanation of Laboratory Vacuum Adsorption Platform: Flatness is the Cornerstone of Successful Coating
The vacuum adsorption platform is a key device in coating experiments, which stabilizes the substrate by negative pressure adsorption, providing a reference plane for coating. The flatness of the platform surface is crucial, as even minor deviations can lead to defects such as uneven coating thickness or the appearance of streaks.
Surface Tensiometer: Interpreting the Invisible Forces on Liquid Surfaces
Surface tension is the contractile force generated by the uneven forces acting on molecules at the liquid surface, influencing phenomena such as droplet formation and capillarity. Surface tension meters measure this force using techniques like the Wilhelmy plate method, the platinum ring method, or the pendant drop method. Their core components include force sensors, sample stages, and data processing systems.
What are the differences between horizontal airflow and vertical airflow in a clean bench?
Purification workbenches primarily employ two types of air supply methods: horizontal and vertical. In horizontal air supply, the airflow is parallel to the work surface, while in vertical air supply, the airflow moves from top to bottom, forming a laminar barrier. The selection should be based on a comprehensive consideration of experimental needs, sample characteristics, and safety requirements.
For electromagnetic vibration tables, whether to choose sweep frequency or fixed frequency testing standards for simulating transportation is crucial; do not make a random selection if you are unsure.
The electromagnetic vibration table is used to simulate transportation vibrations and test the durability of products and packaging. There are two types of tests: fixed-frequency and sweep-frequency. The selection should be based on the test objectives and relevant standards to avoid arbitrary choices. For new products, it is recommended to first conduct a sweep-frequency test to identify resonance points, followed by fixed-frequency tests as needed.