Handheld Temperature Detector

The handheld temperature detector receives thermal energy radiated from an object's surface through an infrared sensor, converts it into an electrical signal, and displays the temperature reading. It is used for on-site rapid measurement of surface temperatures and for monitoring process temperatures in procedures such as paint drying and plastic molding.
Selection
When selecting, pay attention to whether the measurement range covers the required temperature interval, whether the accuracy level meets the detection requirements, and whether the response time is suitable for dynamic measurement scenarios. Consider the emissivity setting function for the target material, and assess whether the display visibility and the device's protection level are suitable for the usage environment.

Terms

Standards

Instruments

Using electrochemistry principle to detect carbon monoxide, with a range of 0~ 1000ppm, with four Alarm modes and wireless data transmission functions, support temperature compensation algorithm and a variety of usage methods.

$ 254.00

Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.

$ 314.00

Using electromagnetic induction technology, the detection distance is up to 50mm, which can detect 5 * 5 * 1mm aluminum blocks. It is equipped with buzzer, vibration and LED alarm. Sensitivity can be adjusted, and it can work continuously for 6-10 hours.

$ 106.00

Detect NH3 gas, range 0~ 100ppm, resolution 0.1ppm, Response Time T90 ≤ 120s, support sound and light alarm, Operating temperature -10~ 50 ℃, Working time for more than 60 hours, Portable design weighs only 170 grams.

$ 328.00

The speed can reach 30000rpm, the processing capacity is 0.1-1000 ml, the 316L stainless steel dispersion head is corrosion-resistant and high temperature-resistant, and the handheld lightweight design is easy to operate with one hand. It is suitable for rapid shearing and crushing of samples in small containers.

$ 680.00

Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.

$ 106.00

Using electrochemistry detection principle, range 0~ 100ppm, with 4G/WIFI wireless communication and temperature compensation function, support remote monitoring and Data storage, Protection Rating IP66, battery life 12-55 hours.

$ 588.00

Using electrochemistry principle to detect 0~ 30% VOL oxygen concentration, with 4G/WIFI wireless communication function, support temperature compensation algorithm and a variety of filtering algorithms, Response fast and accurate data.

$ 282.00

Conductivity Detector Measurement principle, Measurement range 0-50%, Response Time less than 1 second, with temperature and humidity compensation function, split design for quick detection on site.

$ 230.00

Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.

$ 102.00

Using electrochemistry principle to detect 0-100ppm sulfur dioxide, with 4G/WIFI wireless communication, IP66 Protection Rating, four Alarm modes and 12-55 hours battery life, support remote paraMeter configuration and temperature compensation algorithm.

$ 588.00

Pump sampling ensures stable airflow and fast detection speed; can store 100,000 pieces of data, support different interval recording; has high and low temperature working ability, adapt to -40~ 55 ℃ environment; double alarm and automatic diagnosis function to improve safety.

$ 277.00

The rotating speed can reach 30000rpm, the processing capacity is 1-250ml, the handheld lightweight design is suitable for a small amount of samples in a small container, and the corrosion-resistant stainless steel dispersion head is used for easy disassembly and cleaning. Double insulation protection ensures safety.

$ 709.00

Conductivity Detector temperature compensation technology, Measurement range 8~ 40%, accuracy +/- 0.5%, Response Time 1 second, with backlight display and automatic shutdown function, portable design weight only 175 grams.

$ 267.00

Conductivity Detector principle and temperature and humidity compensation technology, measurement range 5-35%, accuracy +/- 0.5%, Response Time 1 second, integrated design is easy to carry, suitable for on-site rapid detection.

$ 148.00

Articles

Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.