Rotary oscillation with 0~ 300rpm Frequency range, temperature control accuracy of +/- 1 ℃, with 5~ 120 minutes timing function, suitable for a variety of compounds thermostatic foster needs.
Using rotary oscillation mode, Oscillation Frequency 0~ 300rpm adjustable, temperature control accuracy +/- 1 ℃, with 5~ 120 minutes timing function, suitable for a variety of compounds thermostatic foster needs.
Adapt to a variety of Viscometer use, suitable for factory field applications, real-time printing measurement results, no need to hand copy, easy operation, can save labor time.
The equipment is designed with double rollers, with a test load of 5kg, a drop height of 500 + 1000mm, and a rotation speed of 5-20 times/minute to meet the needs of continuous rotary drop testing.
With +/- 0.1 ℃ high temperature control accuracy and 0-200rpm Oscillation Frequency, using rotary oscillation and 8-hole design to ensure experimental Temperature uniformity and Sample Handling conformity.
With internal and external circulation thermostatic function, Temperature range -10~ 100 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, support eight Rotation speed control, repRoducibility +/- 1%, suitable for accurate viscosity testing.
Using the rotary oscillation mode, Oscillation Frequency up to 3000 rpm, swing amplitude of 5mm, through smooth contact to achieve rapid mixing, speed can be adjusted with pressure, suitable for a variety of laboratory applications.
The test program can be uploaded to the Viscometer host, the analysis record data can be collected, the rheological Linear dispersion and Excel can be generated, and five sets of data can be plotted and compared at the same time.
Frequency up to 260rpm, swing amplitude of 20mm, with lighting function, Temperature control accuracy +/- 1.5 ℃, suitable for Sample Handling in thermostatic environment.
With rotary and reciprocating double oscillation mode, temperature control accuracy of +/- 0.1 ℃, temperature fluctuation only +/- 0.1 ℃, Oscillation Frequency 0-300rpm, support timing operation, suitable for multi-sample thermostatic foster needs.
Measurement accuracy of 0.1 ℃, range of 0~ 100 ℃, real-time display of temperature values, suitable for a variety of Viscometer models, to ensure a stable test environment.
Silicone oil standard solution, calibrated viscosity 380cp, capacity 400ml, suitable for Viscometer calibrating.
Measurement accuracy +/- 2%, equipped with 5 calibrated oils to ensure measurement accuracy, as a special accessory for cone-plate viscoMeter to achieve stability testing.
The shear rate is 2.0N, only 0.5ml sample volume can be completed to complete the test, suitable for a variety of models of Viscometer host, to meet the measurement needs of different viscosity ranges.
Provides accurate viscosity values of 5.7cp, 400ml per bottle for Viscometer calibrated measurement Stability and Reliability.