Heating Magnetic Suspension Stirrer

The heating magnetic stirrer works by rotating a magnet at the bottom to drive the magnetic stir bar inside the container, achieving liquid mixing. The heating function is provided by an electric heating plate for temperature control. It is used for solution reactions in the laboratory that require heating and stirring, such as dissolution, synthesis, and other operations.
Selection
When selecting, consider matching the heating temperature range with the sample requirements, and ensure the stirring speed meets the uniformity requirements for mixing. The material should be corrosion-resistant, and the capacity should be compatible with commonly used container sizes. The operating interface should be simple and intuitive, with safety features including overheat protection and a non-slip base.

Terms

Standards

Instruments

Heating power 800W, speed range 0-2600 rpm, support vacuum reaction and pressure reaction for a long time stirring, with durable magnetic steel and PTFE stirrer.

$ 209.00

Heat collection heating method is adopted, the solution is heated uniformly and quickly, energy-saving and efficient. Temperature range is as wide as 300 ℃, speed range is 0-2600 rpm, durable magnetic steel and PTFE stirrer are equipped to support long-term stirring under vacuum and pressure reactions.

$ 243.00

DC brushless motor design, Rotation speed 0~ 2000rpm, put in the stirrer without hopper; double-decked thermal insulation structure, rapid heating and prolong the life of the host; built-in over-temperature protection device, safe and reliable use.

$ 222.00

With a maximum stirring capacity of 1000ml and 300W Heating power, stepless speed regulation can precisely and stably stir liquids within the range of 2400rpm, especially suitable for small volume sample testing, easy to operate.

$ 159.00

Using infrared heating technology, the heating speed reaches 5 ℃/sec, Temperature uniformity 1-3 ℃, supports internal and external temperature sensor switching, equipped with 6 independent stations, Max. stirring Capacity 18L, DC motor runs smoothly.

$ 1663.00

Heat collection heating method, heating speed and energy saving, Temperature range up to 300 ℃, speed range 0-2600 rpm, support vacuum reaction and pressure reaction for a long time stirring.

$ 180.00

15 Station Synchronous Stir, Nano heating technology implementation fast uniform heating, speed range 100-1100rpm continuously adjustable, Max.stirring Capacity 7.5L, Microcrystalline Pottery and porcelain panel acid and alkali easy to clean.

$ 1461.00

Double station synchronous operation, heating power 150W × 2, Temperature range RT +~ 100 ℃, using DC motor to ensure no noise and no vibration, fast IT single chip microcomputer to achieve accurate speed control.

$ 128.00

Maximum stirring capacity 3 liters, stirring speed 200~ 1800rpm stepless speed regulation, Heating power 450W, Temperature range RT + 5~ 320 ℃, using aluminum alloy die-casting shell, high temperature corrosion resistance easy to clean.

$ 311.00

It adopts no mechanical heating component design, which can dry burn and no electromagnetic field interference; it only takes 4 minutes to heat up to 400 ° C, and the temperature control accuracy reaches +/- 1 ° C; Microcrystalline Pottery and porcelain plate surface combined with aluminum alloy shell, corrosion resistance and easy cleaning.

$ 453.00

Using brushless DC motor to achieve stepless speed regulation of 0~ 1500rpm, equipped with strong magnetic steel to ensure strong stirring force and stable Rotation speed, Temperature range RT +~ 150 ℃, Heating power 360W adjustable, support mechanical timing 20~ 120min.

$ 212.00

The maximum heating temperature is 300 ° C, the stirring speed is 0~ 1250rpm, the stirring time and thermostatic temperature can be set, and the external temperature sensor automatically controls the temperature to prevent the stirringRod from stalling.

$ 240.00

Maximum heating temperature 400 ° C, stirring speed 0~ 1250rpm, support external temperature sensor automatic thermostatic, key Rotation speed setting to prevent stirringRod stall, large screen LCD display temperature and stirring status.

$ 259.00

It is designed without mechanical heating components, which can dry burn and have no electromagnetic field interference. It only takes 8 minutes to heat up 450 degrees at an extremely fast speed, and the temperature difference of the board surface is 1-3 ° C. Support internal and external temperature Probe switching, equipped with over-temperature alarm and timing function.

$ 1179.00

Maximum stirring capacity 12 liters, Heating power 750 watts, with microcomputer control technology to ensure that Rotation speed is constant, aluminum alloy die casting shell high temperature corrosion resistance easy to clean, LCD screen display a number of paraMeters.

$ 441.00

Articles

Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Laboratory Application Scenarios of Milligram Precision Balances
The milligram precision balance can accurately weigh up to 0.001 grams, primarily utilizing electromagnetic force compensation technology, and its performance is related to parameters such as repeatability and linearity error.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Differences in Measurement Principles Between Magnetic Method and Eddy Current Method for Coating Thickness Gauges
Coating thickness gauges primarily utilize two measurement principles: magnetic method and eddy current method. The selection of the method should be based on the characteristics of the substrate material to ensure measurement accuracy.
For electromagnetic vibration tables, whether to choose sweep frequency or fixed frequency testing standards for simulating transportation is crucial; do not make a random selection if you are unsure.
The electromagnetic vibration table is used to simulate transportation vibrations and test the durability of products and packaging. There are two types of tests: fixed-frequency and sweep-frequency. The selection should be based on the test objectives and relevant standards to avoid arbitrary choices. For new products, it is recommended to first conduct a sweep-frequency test to identify resonance points, followed by fixed-frequency tests as needed.
What is a Coating Thickness Gauge? A Complete Analysis of Its Principles, Usage, and Application Areas
The article systematically elaborates on the working principles of two core measurement techniques, magnetic induction and eddy current, detailing the standard measurement process from calibration to data recording, and conducting an in-depth analysis of the influence of substrate characteristics, geometric shapes, and environmental factors on measurement accuracy.
Huinou Laboratory Automatic Film Coater: Bringing Simplicity and Precision Back to Coating Experiments.
The Huiniao Experimental Automatic Coating Machine addresses common operational pain points in material R&D through features such as snap-on wire rods, flip-top magnetic scrapers, servo motor drives, and a high-flatness work surface. These designs enhance cleaning convenience, reduce maintenance costs, and improve coating stability.