Ammonia Rapid Detector

The ammonia rapid detector is based on electrochemical or optical sensors to measure the concentration of ammonia in the air. The instrument draws in gas samples, and the sensors react with ammonia to produce changes in electrical or optical signals, which are then converted into concentration readings. It is used for leak monitoring and air quality inspection in locations such as feed mills, cold storage facilities, and chemical workshops.
Selection
When selecting, ensure the detection range covers the application scenario's concentration and the resolution meets accuracy requirements. Consider whether the response time and recovery time align with on-site demands. Check the sensor lifespan and calibration cycle. Confirm that the protection rating is suitable for the usage environment. Understand the configuration of data logging and alarm functions.

Terms

Instruments

Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.

$ 209.00

Conductivity Detector principle and temperature and humidity compensation technology, measurement accuracy of +/- 0.5%, Response Time of 1 second, integrated design supports on-site rapid detection, suitable for a variety of grain moisture measurement.

$ 112.00

Colorimetric digestion integrated tube operation, no liquid transfer; water samples for more than 10 measurements to take the average value; ammonia nitrogen detection limit of 0.01mg/L, measurement error ≤ +/- 5%, data storage 30,000.

$ 1493.00

Dedicated to calibrating ammonia Gas sensing electRodes, capacity 250ml, providing accurate calibrating support to ensure Reliability of detection data.

$ 110.00

Measurement range 0.000~ 4.000mg/L, including Noll Reagent and potassium sodium tartrate solution, suitable for rapid detection of ammonia nitrogen in water quality, supporting special instruments.

$ 164.00

Measurement range pN value of 0.00~ 8.00, ammonia nitrogen concentration of 0.05~ 1000mg/L, with automatic mixing and thermostatic system, anti-sample Color, metal ions and turbidity interference, support a variety of reading methods.

$ 1806.00

Electrochemical sensor for rapid Response, detection accuracy of +/- 2% F. S, with Intrinsic Safety (IS) design and a variety of signal output interfaces, support remote monitoring and data transmission, adapt to -30~ 50 ℃ working environment.

$ 888.00

Electrochemical sensor for rapid Response, detection accuracy of +/- 2% F. S, with RS485 and 4-20mA output, explosion-proof design for hazardous environments, support for remote monitoring and multi-system compatibility.

$ 630.00

250Ml Encasement Specification for Ammonia Gas Sensitive and Ammonium Ion Composite ElectRode, provides routine concentration adjustment for measurement accuracy and Stability.

$ 127.00

Conductivity Detector measurement principle, Response Time is only 1 second, with temperature and humidity compensation technology, measurement accuracy +/- 2%, split design is easy to carry on site, support 3 sets of measurement code storage.

$ 230.00

Electrochemical sensor, Response Time ≤ 20 seconds, range 0-100ppm, resolution 0.1ppm, waterproof, dustproof and explosion-proof design, support sound and light vibration triple alarm and Sensor fault self-check function.

$ 202.00

Imported cold light source technology life of 100,000 hours, support 0.001mg/L high Sensitivity detection, with digestion Colorimetric integrated tube design to achieve safe and fast measurement, can store 4000 sets of data and support multi-mode power supply.

$ 2946.00

The filling liquid capacity of 30mL, the use of PTFE bottles, Dimension 65mm high × 30mm diaMeter, weight of only 20g, suitable for the maintenance of Ammonia Gas sensing electRode.

$ 135.00

ElectRode filling solution, suitable for ammonia Gas sensing electRode maintenance, capacity 480 ml, can effectively adjust the ionic strength, improve ElectRode Response Speed and Measurement accuracy.

$ 135.00

The imported cold light source has a lifespan of 100,000 hours, a detection limit of 0.05mg/L, supports continuous measurement and standard Measurement mode, and has 4000 sets of data storage and various transmission interfaces.

$ 816.00