Laboratory Multipurpose Disperser

The laboratory multi-purpose disperser uses a high-speed rotating dispersion disc to generate shear force, breaking down material particles and ensuring uniform mixing. It is used for emulsifying, dispersing, and blending samples such as coatings and inks, making it suitable for small-batch preparation and process testing in laboratory settings.
Selection
When selecting, consider matching the material viscosity with the motor power, determine the diameter of the dispersion disk based on the container size, require speed adjustment function to adapt to different process stages, pay attention to the corrosion resistance of materials, ensure the fixing method adapts to the container shape, and note that heat dissipation design affects continuous working time.

Terms

Standards

Instruments

Adopt frequency conversion motor to achieve stepless speed regulation of 60-8000rpm, equipped with dispersed impeller and sand grinding blades, dual-axis constant force lifting system is easy to operate, and digital PID technology ensures Rotation speed control accuracy.

$ 493.00

Adopt spring electric lifting system, Travel 200mm; Frequency conversion motor Power 750W, speed range 60-8000rpm; with dispersed impeller and sand grinding blades, can be adapted to jacket chill down Mixing Tank for multi-purpose experimental operation.

$ 733.00

Equipped with a 60mm diaMeter 304 stainless steel dispersion plate, it is corrosion-resistant and easy to clean; the lifting stroke is 11 to 42 centiMeters, which can be flexibly adapted to different containers; the handling capacity is up to 25 liters, meeting the needs of medium-scale experiments.

$ 351.00

Using frequency conversion electromechanical, low noise and quiet operation, electric lift Travel up to 400mm, speed range 0-7500rpm, suitable for 0-20L Processing capacity.

$ 1364.00

Standard Processing capacity 500-10000ml, suitable for HR series Disperser, suitable for efficient dispersion processing of large-volume samples.

$ 514.00

Processing capacity range of 100~ 5000ml, maximum processing viscosity of 5000CP, suitable for a variety of Disperser models, providing stable Sample Handling ability.

$ 451.00

Processing capacity range of 100~ 7000ml, maximum processing viscosity of 8000CP, suitable for high viscosity materials efficient dispersion processing, suitable for a variety of Disperser models.

$ 451.00

Set dispersion and Stir functions in one, the processing capacity of 2~ 5kg, speed range of 100~ 8000rpm, manual lifting is simple and convenient, suitable for fluid material experiments.

$ 425.00

Processing capacity 100-6000ml, maximum processing viscosity 8000CP, suitable for a variety of models of Disperser, cutter head design to optimize the dispersion effect, adapt to different capacities and viscosity Sample Handling needs.

$ 451.00

With a speed of up to 30000rpm and a processing viscosity of 10000mPas, the claw-type high-shear structure and interchangeable stator and rotor provide triple safety protection and continuous 6-speed regulation, ensuring efficient dispersion and durability.

$ 1224.00

The stepless speed range is 0-4000 rpm, the lifting stroke is 32 cm, and the working height can be flexibly adjusted. Equipped with 304 stainless steel dispersion disc, it is corrosion-resistant and easy to clean, and supports continuous and stable operation.

$ 273.00

The equipment adopts electronic constant force speed regulation, Speed range 100~ 8000rpm, maximum processing viscosity of 15000mPa.s, high-speed shearing and high-frequency mechanical effects to achieve efficient mixing and dispersion.

$ 414.00

Speed up to 30000rpm, the maximum processing viscosity of 10000mPa.s, the use of claw high shear head structure and triple safety protection, can quickly homogenize tissue samples, stator and rotor interchangeable cost savings.

$ 1263.00

Speed range 60~ 8000rpm, Power 550W, using variable frequency motor to achieve stepless speed regulation, digital direct display Rotation speed, dual-axis constant force lifting system is easy to operate, low noise and no interference.

$ 504.00

The use of electric lifting system to achieve 320mm Travel adjustment, frequency control range of 60-6900rpm, equipped with multi-specification impeller and chill down jacket structure, can meet the needs of stirring and dispersing under different material viscosity.

$ 1006.00

Articles

Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Study on the Dispersion Uniformity of Blade Coating Machines in High-Load Electrode Slurry Coating
This article investigates how to optimize the dispersion uniformity of coatings by adjusting process parameters when using a blade coater to handle high-load electrode slurries.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Capacity Matching for Laboratory Small Dispersers and Pilot Dispersers
This article primarily discusses how to select the appropriate disperser for laboratory research and process development.
Laboratory dispersers achieve efficient dispersion of paint pigments.
This article introduces how laboratory dispersers efficiently disperse paint pigments. They break up pigment agglomerates through mechanical actions such as shear force, involving three stages: wetting, dispersing, and stabilizing.
Selection of disperser speed range and matching of dispersing disc form with container
This article discusses the technical points in the selection of a disperser, including the speed range, the form of the dispersion disc, and the matching with the container.
How to Match the Selection of Fineness Gauge with Grinding Process Requirements
The fineness gauge is used to measure the particle dispersion of materials such as slurries and coatings, reflecting the particle size distribution through the depth of grooves on its surface.
Laser particle size analyzer measures the particle size distribution of spray powder.
Laser particle size analyzers measure the particle size distribution of sprayed powder based on the principle of light scattering, which is critical for coating uniformity and adhesion. During measurement, the powder must be dispersed in a suitable medium to avoid agglomeration, and tests should be repeated to ensure accuracy.
Operating Specifications and Result Interpretation of Paint Fineness Gauges
The fineness gauge is used to measure the dispersion of particles in paint. During operation, the sample should be applied to the groove under standard conditions, and a scraper is used to spread it evenly to form a wet film. The particle visibility is then observed under appropriate lighting, and the fineness value is read from the corresponding scale.
The laboratory pulp wet disintegrator is used for pulp disintegration treatment.
The laboratory pulp wet disintegrator is a device used to simulate the industrial pulping process. It disperses pulp fibers into individual fibers or small fiber bundles through mechanical action, while simultaneously promoting fiber swelling and fibrillation, thereby providing standardized samples for subsequent performance evaluation.
The impact of the disperser impeller structure on dispersion effectiveness.
This article mainly discusses how the impeller structure of a disperser affects the dispersion effectiveness. The impeller is the core component of a disperser, and its design directly influences the uniformity and stability of the final mixture.
Application of High-Speed Disperser in the Preparation of Water-Based Inks
This article introduces the application of a high-speed disperser in the preparation of water-based inks. It first explains the working principle of the equipment, which involves generating shear forces through high-speed rotation to disperse particles.
Ink fineness gauge measures the dispersion degree of pigment particles.
The fineness of grind gauge is a method used to evaluate the dispersion level of pigment particles in ink.
Comparison of Pigment Fineness Dispersion between Flat Grinding Mill and Sand Mill