Melt Mixer

The melt mixer drives the blades to rotate via an electric motor, ensuring uniform mixing of materials within the heating chamber and achieving the set temperature. It is used for the blending and dispersion of materials such as plastics and rubber in a molten state. It is commonly employed in laboratory sample preparation and small-batch production.
Selection
When selecting, consider matching the material viscosity with the stirring torque, ensure the heating temperature covers the experimental range, select materials with corrosion resistance corresponding to the material characteristics, provide adjustable stirring speed to ensure uniform mixing, determine the capacity based on sample volume, and ensure safety features include overheat protection and insulation design.

Terms

Standards

Instruments

Temperature control accuracy of +/- 0.5 ℃, equipped with eight standard test force, can accurately determine the melt flow performance of polymers at high temperatures, to meet a variety of material testing needs.

$ 977.00

Adopting MCU to adjust power and temperature control mode, temperature control accuracy +/- 0.5 ℃, with eight standard test force, can meet the needs of different material testing, suitable for melt flow performance measurement at high temperature.

$ 945.00

Equipped with 8 Meters Oven, roller heating temperature up to 200 ℃, effective application width 500mm, Spreader thickness range 0.005-3mm, support automatic unwinding to winding process, suitable for hot-melt adhesive film.

$ 29120.00

Temperature range 50~ 400 ℃, thermostatic accuracy +/- 0.5 ℃, equipped with eight standard test force, can accurately determine the flowability and viscosity of polymers in molten state and other physical properties.

$ 993.00

Using Hastelloy heating cylinder to avoid high temperature oxidation, dual Sensor temperature control accuracy of +/- 0.5 ℃, support strong corrosion plastic test, with four minutes countdown and RS232 data output function.

$ 933.00

32 5ml centrifuge tubes can be installed vertically on both sides, using a vertical installation design, suitable for HT-X100 swirl/spin Mixer, improving Sample Handling efficiency.

$ 149.00

The thickness range of Spreader is 0.01mm~ 2mm, the minimum gluing thickness is 0.01mm, the coating surface density ≤ +/- 1.5%, the dial Meter is used to fine-tune the gap and the Teflon baffle to adjust the width, and it supports forward and reverse continuously variable speed and automatic winding.

$ 4269.00

Double-sided horizontal mounting design can accommodate 40 centrifuge tubes simultaneously, compatible with 1.5ml and 2.0ml specifications, suitable for swirl/spin Mixer for efficient Sample Handling.

$ 149.00

Adopting rotary oscillation design, Frequency 3000rpm, pendulum amplitude 5mm, suitable for small containers such as testtube and Colorimetric tube, it can efficiently handle the experimental requirements of large chemical reactions and few solutions.

$ 125.00

The equipment adopts High Accuracy modular Spreader station, all-electric control without air source, minimum glue thickness 0.01mm, Spreader speed 2-4.5 m/min adjustable, with electronic control precision tension to adapt to a variety of materials such as paper, plastic and metal film.

$ 5721.00

Using the rotary oscillation mode, Oscillation Frequency up to 3000 rpm, swing amplitude of 5mm, through smooth contact to achieve rapid mixing, speed can be adjusted with pressure, suitable for a variety of laboratory applications.

$ 133.00

Using stepless speed regulation technology, Speed range 0~ 2800rpm, turnover diaMeter 4mm, support point and continuous Operating Mode, high performance motor to ensure rapid mixing and low noise.

$ 208.00

High Accuracy modular Spreader station structure, Spreader thickness range of 0.01mm to 2mm, coating speed 2-4.5 m/min adjustable, support forward and reverse stepless variable speed and automatic winding, gap adjustment Graduation up to 0.001mm, easy to accurately control the Spreader process.

$ 5399.00

Rotation speed 2500rpm, can handle 2000ml volume sample, integrated magnetic stirring, vortex mixing and microplate oscillation multi-function.

$ 396.00

With magnetic stirring function, the maximum stirring capacity of 2000ml, Speed range 200-2500rpm, vibration range 4.5mm, support point and continuous operation mode switching.

$ 359.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.
Melt flow index instrument controls the flowability and stability of polypropylene injection molding process.
This article explores how to assess and regulate the stability of polypropylene's flowability in injection molding processes by measuring its melt flow rate. It explains the principles behind characterizing flowability and analyzes the impact of factors such as material batch variations and process parameters on stability.
Melt Flow Index Tester for Measuring Plastic Flowability to Control Process
A melt flow indexer evaluates the melt flow rate of plastics by measuring the extrusion mass or volume under specific temperature and load conditions.
Rotational Viscometer Measures Viscosity and Processability of Resin Melts
A rotational viscometer calculates viscosity by measuring the torque experienced by a rotor as it rotates in the resin melt, thereby helping to understand the material's processing properties.
The melt flow indexer measures the flow rate of thermoplastic resins.
A melt flow indexer is a device used to measure the flowability of thermoplastic resins. It calculates the melt flow rate by determining the mass or volume of the melt that passes through a standard die within 10 minutes under specific temperature and pressure conditions.
How does a melt flow indexer affect the processing stability of modified plastics?
A melt flow indexer is a device used to determine the melt flow rate of thermoplastic materials under specific temperature and load conditions. The measurement is typically expressed as the mass (in grams) extruded per ten minutes, known as the melt flow rate (MFR) or melt mass-flow rate (MFR).
Melt Flow Indexer Evaluates Fluidity of Thermoplastics
A melt flow indexer is a device used to test the flowability of thermoplastic plastics. It measures the mass or volume of plastic extruded from a standard die per unit time under specific temperature and pressure conditions to determine the melt flow rate.