Conductivity Monitor

Conductivity monitors measure the electrical conductivity of a solution through electrodes, reflecting ion concentration. They are used for water quality monitoring and industrial process control, detecting changes in solution purity or concentration in wastewater treatment and chemical production processes.
Selection
Select the range based on the measurement scope, considering the temperature compensation function. The electrode material must match the medium characteristics, and the protection rating should suit the installation environment. Output signals should interface with the control system, and regular calibration ensures data accuracy.

Terms

Standards

Instruments

With pH, conductivity, TDS and temperature Multi-ParaMeter measurement, pH range 0.0-14, EC range 0-3999 μS/cm, supports Automatic calibration and continuous monitoring, waterproof design and large screen display for easy operation.

$ 538.00

Non-contact Sensor to reduce measurement drift, conductivity Measurement range of 0-10000 μS/cm, temperature accuracy of 0.1 ℃, support up to 3 years of battery life and 70 Meters water depth working environment.

$ 1719.00

Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.

$ 106.00

Support conductivity, TDS, salinity and resistivity Multi-ParaMeter measurement, conductivity range 0.000 μS/cm to 1000mS/cm, with intelligent end point determination and automatic temperature compensation function.

$ 741.00

Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.

$ 314.00

Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.

$ 102.00

Suitable for low conductivity water samples with conductivity above 100 µS/cm, using polymer liquid junction design, pH Measurement range 0-11pH, Temperature Measurement range 0-80 ℃, no need to add liquid reference system.

$ 208.00

Measurement range 0-2μS/cm with Mini-DIN 8 core connector for accurate detection of low conductivity solutions.

$ 199.00

Using Platinum Sensor to ensure linear stable measurement, Conductivity Detector cell constant K = 0.1, Glass shell corrosion resistance, suitable for 0~ 80 ℃ Operating temperature environment.

$ 206.00

Conductivity Detector 111800μS/cm@25 ° C with a capacity of 500ml provides accurate and reliable measurement of Conductivity Detector values, ensuring instrument calibrate accuracy and repeatability.

$ 127.00

Simultaneous measurement of conductivity, resistivity, TDS, salinity and temperature, support automatic temperature compensation and ElectRode diagnosis, Data storage 450 groups, with IP54 dustproof and waterproof rating, Measurement accuracy up to +/- 1.0% FS.

$ 514.00

Measurement range 0.00μS/cm~ 100mS/cm, error +/- 0.5% F. S, temperature compensation coefficient 2%, LED display is clear, Stability is high, suitable for accurate conductivity detection.

$ 215.00

Providing 80,000 μS/cm@25 ° C standard Conductivity Detector values, the 500ml bottle is designed for easy laboratory operation, ensuring the accuracy and repeatability calibrated of the Conductivity Detector measuring instrument.

$ 127.00

Support conductivity 0.00μS/cm~ 100mS/cm and TDS 0~ 1000mg/L measurement, with manual/automatic temperature compensation and +/- 0.5% F. S error accuracy to ensure stable and reliable data.

$ 233.00

Using platinum sheet material, Conductivity Detector cell constant 0.1, no temperature compensation function, suitable for pure water and ultra-pure water and other water quality measurement, optional Glass flow Tank.

$ 185.00

Articles

Positive pressure method seal tester evaluates packaging pressure resistance
This article introduces how the positive pressure method sealing tester evaluates the pressure resistance of packaging. The instrument simulates actual pressure conditions by injecting compressed air into the packaging and then monitors pressure changes to determine if there is any leakage.
Tensile testing machine measures the bending fatigue life of flexible OLED films.
This article introduces a method for testing the bending fatigue life of flexible OLED films using a tensile testing machine. The test simulates repeated bending to evaluate the accumulation of damage in the film under cyclic stress, and monitors performance changes to determine the failure point.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Operating Specifications for the Determination of Hexavalent Chromium Content in Wastewater Using Colorimetric Titration Apparatus
This article introduces the standard operating procedure for determining hexavalent chromium content in wastewater using a colorimetric titrator. The method is based on the reaction between hexavalent chromium and diphenylcarbazide under acidic conditions to form a purplish-red complex, with the titration endpoint determined by monitoring changes in absorbance at a wavelength of 540 nanometers.
Application of Automatic Potentiometric Titrator in Chloride Ion Detection in Drinking Water
This article introduces a method for detecting chloride ions in drinking water using an automatic potentiometric titrator. The principle involves allowing chloride ions in the water sample to react with silver nitrate to form a precipitate. The instrument monitors changes in potential through an electrode, automatically determines the endpoint of the reaction, and calculates the chloride ion content.
Experimental Verification of Stroke Accuracy on Coating Thickness Repeatability for Desktop Automatic Film Applicators.
This article investigates the influence of the stroke accuracy of a desktop automatic coating machine on the repeatability of coating thickness. The experiment monitored the blade position deviation using high-precision sensors and measured the coating thickness, revealing that smaller stroke deviations lead to better repeatability in coating thickness.
Total Chlorine Content Microcoulometric Titration Detector for Pulp
This article introduces a method for detecting the total chlorine content in pulp using a microcoulometric titrator. The principle involves generating a titrant through electrolysis, which reacts with chloride ions produced from the combustion of the sample. The chlorine content is accurately calculated by monitoring the amount of electricity consumed.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Principle and Application of Vacuum Decay Leak Testing Equipment
The vacuum decay leak tester is a non-destructive detection device that quantitatively detects leaks by monitoring minute pressure changes in the test chamber after vacuum evacuation.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
How does the instrument calculate total dissolved solids in water from conductivity?
This article explains how TDS instruments estimate total dissolved solids by measuring the electrical conductivity of water. Since most dissolved solids exist in ionic form, which affects conductivity, there is a correlation between the two.
Drying Time Determination: Simultaneous Verification of Surface Drying Test Method, Through-Drying Test Method, and Instrumental Test Method
This article discusses three methods for determining the drying time of materials such as coatings. Traditional methods are divided into surface drying and through drying measurements, which are simple to operate but rely on subjective judgment. Instrumental methods provide objective data by monitoring physical changes such as mass and resistance, offering higher precision but at a higher cost.
How to Choose the Right Contact Angle Measuring Instrument Based on Sample Characteristics
Contact angle measurement is a key method for evaluating the wettability of solid surfaces and is widely used in fields such as materials science, coating industry, textile testing, electronic packaging, and environmental monitoring.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.