Double pointer design for easy reading, Pin Travel 0~ 2.5mm, Measurement range 0~ 100HD, error +/- 1HD, lightweight and portable only 0.16kg, suitable for on-site Hardness detection.
Adopt double-pointer design, pressure needle Travel 0~ 2.5mm, measurement error +/- 1HAO, can be handheld or used with the bench, suitable for stable and fast detection of low Hardness rubber materials.
With tracking pointer and peak pointer double pointer design, pressing needle Travel 0-2.5 mm, Measurement range 10-90Hc, suitable for material testing with pressure above 0.049MPa when the compression rate is 50%, and can be matched with test bracket to improve Stability.
Pin Travel 0~ 2.5mm, Measurement range 0~ 100HA, Error +/- 1HA, Dual pointer design can display real-time and peak Hardness value at the same time, easy to use handheld or rack.
Dual pointer design can display the current value and peak value at the same time, the pressure at the end of the crimp is 445mN, and the measurement error is +/- 1HD, which is suitable for plastic sample condition adjustment testing.
Supporting D-type Shore DuroMeter, applying 5kg test force by weight, equipped with Glass bench and adjusting nut to ensure full contact with the sample and improve measurement Stability.
Can be used with A type or C type Shore DuroMeter, fixed load weight mass 0.75 +/- 0.05kg, hardness Gauge clamping Rod connection size M7x0.5mm, improve hardness testing accuracy and Stability.
Suitable for low and medium Hardness material measurement, pressure needle end pressure 0.55N-8.06N, pressure needle stroke 0-2.5 mm, can be matched with test rack to reduce manual operation error, improve test accuracy and Repeatability.
Double pointer design can be used with rack or hand, pressing needle Travel 0-2.5 mm, measurement error +/- 1HA, suitable for rubber and plastic hardness testing.
Measurement range is 0~ 100HA, resolution up to 0.1HA, measurement error ≤ +/- 1HA (20-90HA), Ambient Temperature 0~ 40 ℃, Dimension 173 * 56 * 42mm, weight 233g, support RS232 communication cable.
Measurement range > 90B < 20D, support male/imperial unit conversion, with average calculation and MAX Maximum latch function, can output data in various ways through USB/RS-232/Bluetooth.
Measurement range 20~ 90A, with MAX Maximum latch, under-voltage alarm and male/imperial unit conversion function, support USB and Bluetooth data output.
Resolution 0.1H, Accuracy ≤ 1H, Measurement range 10~ 90 HA/HD; Integrated design is lightweight, supports male/imperial conversion, average calculation and a variety of data output methods.
Equipped with a 1kg fixed load weight, pressing the specimen at a speed of 3.2mm/s, providing stability testing conditions, suitable for standard Hardness measurement, preventing vibration from affecting the results.
Double pointer design with peak holding and continuous load indication function, external tolerance indicator to facilitate force value judgment, Maximum Measured value 10KN, suitable for electromagnetic interference occasions.