Adopt cascade refrigeration system to achieve -70 ℃ low temperature, with 1000 segment program control capacity, support RS-232 communication interface and Chinese and English display switching, Temperature Uniformity up to +/- 1.0 ℃ and humidity fluctuation +/- 2.0% RH.
Built-in High Accuracy Temperature Humidity Sensor, Temperature Error +/- 0.2 ℃, Humidity Error +/- 2.5%. Adopt Bluetooth low energy wireless transmission, support remote setting and data download, with weatherproof housing and NEMA6/IP67 Protection Rating, suitable for long-term outdoor monitoring.
Using Japan's Panasonic Compressor and the United States DuPont environmental protection refrigerant, temperature control accuracy of +/- 0.5 ℃, Temperature resolution 0.01 ℃, with program control and Data storage functions, support high temperature, low temperature and heat and humidity alternating test.
Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, automatic thermostatic control, fast drying and low energy consumption.
Using Japanese Panasonic Compressor and binary low temperature circuit system, temperature control accuracy of +/- 0.5 ℃, equipped with stainless steel humidifier and nickel-chromium alloy heater, support programmed test and data recording function, to meet the demanding environment simulation needs.
Using Japan Panasonic Compressor and binary low temperature circuit system, Temperature range -70 ℃~ + 150 ℃, Temperature Uniformity ≤ 2 ℃, equipped with double-decked vacuum Glass observation window and automatic water replenishment device.
Adopt cascade refrigeration system to achieve -70 ℃ low temperature, with 1000 segment program control and automatic calculation function, equipped with 15 safety detection devices and RS-232 communication interface, Temperature Uniformity of +/- 1.0 ℃.
Adopt 7-inch touch controller to support 120 program settings, equipped with multi-wing air supply system to ensure uniform distribution of temperature and humidity, Temperature Fluctuation +/- 0.5 ℃, humidity deviation +/- 2% R.H to ensure test accuracy.
With 1000 segment program capacity and 999 step cycle, temperature control accuracy +/- 1 ℃ humidity control accuracy +/- 2% RH, using cascade refrigeration system and steam humidification method, support reservation start and fault self-diagnosis function.
Temperature range -60~ 150 ℃, humidity control 20~ 98% RH, multi-wing air supply circulation to ensure uniform temperature and humidity, support LAN interface remote monitoring and data export.
The cascade refrigeration system is used to achieve a low temperature of -60 ° C, equipped with a 1000-segment program control capacity, with automatic calculation and fault self-diagnosis functions, and supports RS-232 communication interface to realize multi-machine control.
Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, fast and low consumption, equipped with thermistor temperature control, the studio is made of 304 stainless steel, size 750 * 600 * 600mm, easy to adjust, suitable for drying treatment of various samples.
Adopt 7.0 inch large screen controller, temperature control accuracy +/- 0.1 ℃, humidity control accuracy +/- 1% R.H., equipped with independent temperature limit alarm system, support multi-wing air supply cycle to ensure uniform temperature.
Temperature range -50~ 150 ℃, humidity control 20~ 98% RH, with 1000 program control capacity, support automatic calculation and fault self-diagnosis function, using cascade refrigeration system to ensure stable performance.
Multi-wing air supply cycle is used to ensure uniform temperature and humidity, support 120 sets of program control and data export functions, Temperature Fluctuation +/- 0.5 ℃, to meet a variety of industrial standard testing requirements.