Standard Gloss Meter

A standard gloss meter evaluates glossiness by measuring the specular reflectance of light on the surface of an object, using a fixed-angle light source and receiver to detect the intensity of reflected light. It is used for surface quality inspection of coatings, plastics, etc., to ensure consistent product appearance.
Selection
When selecting, consider the measurement angle range: use 20 degrees for high-gloss surfaces, 60 degrees for normal surfaces, and 85 degrees for low-gloss surfaces. Ensure the instrument complies with ISO/ASTM standards. Check the calibration certificate and measurement repeatability. Choose an appropriate probe based on the sample size.

Terms

Standards

Instruments

45 ° ring illumination and 0 ° viewing angle structure are used to effectively eliminate mirror light interference on textured surfaces. Built-in Gloss Sensor realizes simultaneous measurement, and the spectral reflectance Repeatability Standard Deviation is within 0.08%, suitable for matte and textured materials.

$ 3753.00

Adopt 60 ° Measurement Angles, Measurement range 0~ 199.5GU, Indication Error +/- 2GU, built-in rechargeable battery can last for more than 24 hours to meet the needs of surface Gloss measurement of various materials.

$ 283.00

The 45 ° ring illumination structure is used to eliminate the direction dependence, the Inter-instrument Agreement Delta E * ab Technologies 0.2, the chromatic value Repeatability Delta E * ab 0.03, the built-in Gloss Sensor realizes the simultaneous measurement of Color Gloss, and the test port is designed to support a variety of morphological samples.

$ 9078.00

Using 20 degree Measurement Angles, Measurement range 0~ 300GU, Indication Error +/- 1.2GU, equipped with elliptical measurement port and Ni-MH rechargeable battery, suitable for high Gloss object surface detection.

$ 448.00

Adopt 45 ° circular lighting structure, reduce texture effect, compatible with 60 ° Gloss measurement, Repeatability Delta E * ab 0.03, built-in high Sensitivity Sensor, suitable for matte and textured material surfaces.

$ 6334.00

The three-angle measurement design covers 20 °/60 °/85 °, the measurement range is 0.1~ 200GU, the repeability is +/- 0.5GU, and 254 sets of data storage and Bluetooth output are supported to meet the needs of surface Gloss detection of various materials.

$ 336.00

Adopt 60 ° Measurement Angles, Measurement range 0~ 1000GU, Repeatability 0.2GU, support USB and Bluetooth interface, can store 10000 sample data, suitable for surface Gloss measurement of various materials.

$ 332.00

Automatic shift design to achieve a wide range of 0-1000Gs measurement, both low Gloss and high Gloss surface detection capabilities; LED long life Illuminant and quartz crystal standard version to ensure high Stability and low annual rate of change; portable and lightweight, a battery can be used continuously for nearly 60 hours.

$ 404.00

Using 60 ° Measurement Angles and 0~ 199.9GU Measurement range, with 10 * 20mm Measuring Area and +/- 1.2GU Indication Error, the whole set of instruments is designed in one piece and the measuring port has anti-scratch coating.

$ 364.00

Using 60 ° Measurement Angles and 0~ 199GU range, Repeatability 1GU, single AA battery can work for more than 58 hours, small size and anti-scratch coating to protect the surface of the tested object.

$ 286.00

Support 20 °/60 ° dual angle measurement, Repeatability up to 0.2GU, can measure 0-2000GU range, with haze value calculation and percentage reflectance unit conversion function.

$ 638.00

Automatic calibration and continuous test function, Measurement Angles 60 degrees, Indication Error less than 1.2GU, LED long life Illuminant, energy saving and power saving, two AA batteries can measure nearly 10,000 data.

$ 190.00

Silicone oil standard solution, calibrated viscosity 380cp, capacity 400ml, suitable for Viscometer calibrating.

$ 185.00

Concentration 1000ppm of copper ion standard solution, PTFE bottle Encasement, capacity 480mL, suitable for daily ion calibrating applications.

$ 135.00

Adopt 60 ° Measurement Angles, Measurement range 0~ 199GU, Indication Error +/- 2GU, built-in rechargeable battery, can be used for more than 24 hours on a single charge, suitable for on-site rapid detection.

$ 243.00

Articles

Gloss meter measures the surface brightness of packaging film.
This article introduces the principle and method of using a gloss meter to measure the surface glossiness of packaging films. The gloss meter quantifies the specular reflection capability of a surface in gloss units by measuring the ratio of reflected light from the sample to that from a standard plate.
Gloss meter measures the gloss consistency of resin coating film surfaces.
This article introduces how to use a gloss meter to measure the gloss consistency of resin coating film surfaces.
Application of Gloss Meter in Gloss Measurement of Varnish Coatings
A gloss meter is used to measure the gloss of varnish coatings by detecting surface-reflected light to quantitatively assess the appearance of the coating. The measurement is based on the principle of specular reflection of light, commonly employing angles such as 20°, 60°, and 85° to correspond to different gloss ranges, and follows standard formulas for calculation.
Glossmeter 75-degree angle measurement for paper gloss
This article introduces the principle and method of measuring paper gloss using a 75-degree specular gloss meter. Gloss is defined as the ratio of the light reflected from the paper surface to that reflected from a standard reference plate, with the 75-degree angle commonly used for measuring medium to high gloss papers.
Three-angle gloss meter for evaluating coatings with different gloss levels
Glossiness is a key indicator for evaluating the optical properties of a surface, defined as the ratio of the reflected luminous flux to the incident luminous flux, typically expressed as a percentage or in gloss units.
Method for measuring the gloss of ink surfaces using a gloss meter
This article introduces the method of measuring the surface gloss of ink using a gloss meter. Gloss is a key indicator of the visual quality of ink, and the instrument quantifies gloss by measuring reflected light at specific angles.
The use of a gloss meter in evaluating the surface gloss of printing paper and art paper.
Gloss meters quantify paper gloss by measuring surface reflected light, with 20°, 60°, and 85° angles commonly used for high, medium, and low gloss surfaces, respectively. The gloss characteristics of printing paper and art paper differ, so the appropriate measurement angle should be selected based on the estimated gloss level.
Determination of specular gloss: Selection criteria for instruments at different angles (20°/60°/85°)
Specular gloss is a measure of a material's ability to reflect light, calculated by comparing the reflected luminous flux of a sample with that of a standard plate. Three angles—20°, 60°, and 85°—are commonly used for measurement, corresponding to high-gloss, medium-gloss, and low-gloss surfaces, respectively.