Color measuring instrument for yarn-dyed fabrics

The color measuring instrument for yarn-dyed fabrics quantifies color data by irradiating the sample and analyzing the reflected spectrum. It is used for color comparison and quality control in the production of yarn-dyed fabrics, ensuring color consistency between batches. Its applications span textile mills, quality inspection agencies, and research and development departments.
Selection
When selecting, consider matching the measurement aperture to the fabric texture and ensure compatibility with industry-standard color difference formulas. Pay attention to the inter-instrument agreement index and evaluate repeatability data. Verify that the light source type is suitable for the production environment and confirm that the software functions meet the basic requirements for color fastness rating.

Terms

Instruments

16Mm large diaMeter design, suitable for streak or large area pRoduct color measurement; Repeatability Delta E * ab is less than 0.05, Measurement time is only 0.5 seconds, to ensure stable light leakage.

$ 1445.00

Imported matte aluminum reflector to achieve uniform lighting, equipped with six kinds of Illuminants including D65 and UV, table size 700 * 530mm to meet a variety of color requirements.

$ 687.00

Adopt Φ 4mm measurement aperture and full Light spectrum LED Illuminant, chromatic value Repeatability Delta E * ab 0.05, support cloud color database and a variety of Color difference formula calculation, portable design with dust cover and long battery life.

$ 538.00

Equipped with five Illuminant system, supports D65, TL84 and other Standard light sources, the interior is coated with Moncel gray N5.5, the width is 60cm, and the multi-point Illuminant observation system enhances the accuracy of color evaluation.

$ 4022.00

With five Illuminant system, Color temperature coverage 2700K to 6500K, no need to warm up without flashing, automatic switching Illuminant and display the use time, low energy consumption without heating, support Metamerism function.

$ 403.00

With eight Illuminant automatic switching and Metamerism functions, no preheating and no flickering, low energy consumption and no heat generation, high luminous efficiency, Illuminant includes D65, TL84, etc., and the color temperature covers 2700K to 6500K.

$ 525.00

With six Illuminant automatic switching function, no need to warm up without flashing, low energy consumption without heating, display the use time of each Illuminant, support Metamerism detection, Color temperature coverage 2700K to 6500K

$ 369.00

Provide uniform ink speed three adjustable 450 to 800rpm, color development speed three adjustable 12 to 25rpm, color development pressure range -20 to 80, support ordinary or UV ink roller, improve work efficiency and applicability.

$ 7658.00

With four Illuminant automatic switching function, display the use time of each Illuminant, no need to warm up without flashing, Color temperature range covers 2700K to 6500K, low energy consumption without heating, support Metamerism detection.

$ 354.00

Adopt 8 °/d illumination mode and Φ 4mm measurement diaMeter, chromatic value Repeatability Delta E * ab within 0.1, with Automatic calibration and moving Color Chart database function, support a variety of Color difference formula and Illuminant simulation.

$ 344.00

With seven Spinning & weaving unit conversion functions, it can automatically store 100 data, Response Time ≤ 3 seconds, repeatability error 0.002g, suitable for testing a variety of Spinning & weaving materials.

$ 1203.00

Built-in camera to accurately locate the measurement area, UV Illuminant can measure fluorescent color, Repeatability Delta E * ab ≤ 0.06, supports 26 kinds of Illuminant and 30 + kinds of chroma indicators to meet various measurement needs.

$ 1929.00

Using D/8 lighting mode and full Light spectrum LED Illuminant, Inter-instrument Agreement Delta E * 00 < 0.2, equipped with non-contact automatic whiteboard calibration and multi-function smart buttons, easy to carry and wireless connection, to achieve accurate Color measurement and Color Chart recognition.

$ 231.00

Adopt Φ 4mm measurement aperture and full Light spectrum LED Illuminant, chromatic value Repeatability Delta E * ab within 0.1, support cloud database and popular color search, portable design battery life up to thousands of measurements.

$ 441.00

Driven by numerical control motor, swirl/spin accuracy of 0.1 degrees, support multi-color inks Hue, concentration detection, can anticipate dry and wet ink color change and Abrasion Resistance, 5-10 minutes rapid color development, significantly reduce inks waste.

$ 3107.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
A spectrophotometer uses digital language to describe colors, making color differences impossible to hide.
A spectrophotometer measures the color of an object through spectral analysis, converting reflected light data into spectral curves. It then calculates chromaticity parameters such as L*a*b* based on international standards, achieving a digital representation of color.
How to Interpret Color Difference Lab Values Measured by a Spectrophotometer? Save This Color Difference Judgment Standard Now!
This article explains how spectrophotometers measure and evaluate color differences using the Lab color space. In the Lab values, L represents lightness, while a and b indicate the red-green and yellow-blue color biases. The color difference ΔE is calculated using a formula to quantify the variation between a sample and the standard.