Contains 1 pack of total nitrogen base Reagent, 1 pack of potassium persulfate powder, 25 packs of anti-interference agent and 25 packs of acid Reagent, suitable for DGB-401 instrument, providing complete detection components.
With standard COD, total phosphorus, total nitrogen working procedures, support custom temperature and time; using new temperature control algorithm, heating uniform and fast, heating up to 165 ℃ only 12 minutes, temperature control accuracy +/- 1 ℃; one-button operation, with automatic alarm and transparent protective cover.
Colorimetric integrated tube design is adopted, sample digestion and detection share a tube, no need to transfer liquid; support more than 10 measurements and automatically remove abnormal values to average, error ≤ +/- 5%; can expand the detection of COD, ammonia nitrogen and other paraMeters.
Adopt digestion Colorimetric integrated tube design, no liquid transfer; support more than 10 measurements to take the average value, error ≤ +/- 5%; can store 30,000 data, compatible with 16mm and 25mm Colorimetric tubes.
Colorimetric digestion integrated tube design, no need to transfer liquid; the water sample for more than 10 measurements to take the average value, reduce the error; built-in two COD detection methods, Measurement range 0-20000mg/L.
Adopting digestion Colorimetric integrated tube design, the detection process is safer and more convenient; the minimum display value is 0.001mg/L, and the Sensitivity is high; it supports a variety of detection paraMeter expansion to meet different water quality testing needs.
Colorimetric integrated tube design, no need to transfer liquid, direct display of concentration value; support more than 10 measurements to take the average value, reduce the error; measurement error ≤ +/- 5%, Repeatability ≤ +/- %, Optical inspection Stability is excellent, data storage up to 30,000.
15 minutes to quickly heat up to the set temperature, temperature control accuracy of +/- 0.5 ℃, using multi-point calibrated to eliminate temperature errors, standard imported Glass digestion tube resistant to sudden cooling and sudden heating without bursting.
Colorimetric integrated tube design is adopted, with a detection limit of 0.5mg/L, high temperature digestion at 125 ° C, built-in 4000 data storage and a variety of transmission interfaces to meet the needs of on-site rapid detection.
36-Hole design supports batch processing, temperature control accuracy of +/- 0.5 ℃, rapid heating to set temperature in 15 minutes, multi-point calibrating to eliminate measurement errors, standard imported glass tube anti-burst.
16-Hole design to meet the needs of batch processing, 12 minutes rapid heating to 165 ℃, temperature control accuracy of +/- 1 ℃, equipped with a transparent shield for easy observation, support 5-999 minutes time adjustment.
Colorimetric integrated tube operation, no liquid transfer; measurement error ≤ +/- 5%, Repeatability ≤ +/- %; Support Multi-ParaMeter detection and post expansion, built-in thermal printer and 30,000 data storage.
25-Hole Design Improves Sample Handling Efficiency, Temperature Control accuracy up to +/- 1 ° C to Ensure Digestion Stability, 12-minute rapid warming to 165 ° C to shorten waiting time, Transparent Shield for easy observation of the experimental process.
Colorimetric integrated tube design, supports more than 10 measurements to take the average value, measurement error ≤ +/- 5%, built-in 30,000 data storage and thermal printer, can expand the detection of ammonia nitrogen, total nitrogen and other paraMeters.
Adopt automatic nitrogen measurement distillation system, nitrogen measurement range 0.1-200 mgN, collection rate ≥ 99%, repeability rate < +/- 1% relative to Standard Deviation, semi-automatic working mode, distillation time 5-15 minutes, suitable for a variety of sample analysis.