Glass Thermostatic Water Bath

The glass constant temperature water bath uses electric heating tubes to heat the water medium, and maintains a constant water temperature in conjunction with a temperature control system. It is used for constant temperature heating of laboratory samples, insulation of reactors, and viscosity testing. It is commonly used in chemical and pharmaceutical fields for the handling of temperature-sensitive substances.
Selection
When selecting, pay attention to whether the temperature range and fluctuation meet the experimental requirements, ensure the tank capacity is suitable for the sample size, and the material's corrosion resistance matches the properties of the reagents. Observe the temperature control accuracy, safety protection features, and the convenience of daily maintenance.

Terms

Standards

Instruments

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

With three uses of water Bath, thermostatic and boiling disinfection, Temperature range RT +~ 100 ℃, Tank volume 36L, suitable for a variety of experimental heating and equipment processing needs.

$ 209.00

Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.

$ 493.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

Using digital temperature control technology, Temperature range RT +~ 100 ℃, Tank size 300 * 300mm, combined design operation is more convenient, suitable for long-term stable operation.

$ 277.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

The interlayer vacuum design is easy to keep warm, the test capacity is about 300ml, the upper and lower holes go in and out for easy connection of the thermostatic Bath, easy to use and easy to clean.

$ 146.00

Temperature control accuracy of +/- 0.5 ℃, temperature resolution of 0.1 ℃, equipped with built-in circulating water pump can output thermostatic water flow, support timing function to ensure experimental stability.

$ 214.00

Adopt electromagnetic pump circulation mode, Temperature range 5~ 80 ℃, Temperature Fluctuation +/- 0.2 ℃, equipped with water shortage protection function to prevent accidents, support a variety of interface connections.

$ 433.00

304 stainless steel one-time stretch forming liner, no water leakage; four-corner arc design to ensure temperature uniformity; temperature control accuracy of +/- 0.5 ℃, heating power 600W, to meet the long-term stable thermostatic needs.

$ 160.00

Water Bath, water temperature box and boiling disinfection box three functions, Temperature range from room temperature to 100 ℃, Tank size 42 * 18 * 20cm, to meet a variety of experimental heating and disinfection needs.

$ 180.00

Using digital temperature control, the reading is intuitive and accurate, Temperature range RT +~ 100 ℃, Tank size 300 * 300mm, integrated design and easy operation.

$ 372.00

Articles

Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
DSC analyzer measures the glass transition of degradable films.
This article explains how to use a differential scanning calorimeter to measure the glass transition temperature of a degradable film. It first clarifies that the glass transition is the process by which a material changes from a glassy state to a highly elastic state, which appears as a baseline shift on the curve.
The film coater applies a conductive film onto transparent substrate test pieces.
This article introduces a method for uniformly coating conductive films on transparent substrates such as glass or plastic films using a film applicator.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.
The polymer film is formed by blade coating on a glass substrate using a film applicator.
This article introduces the technique of using a film applicator to doctor-blade polymer films onto glass substrates.
Differential scanning calorimetry for determining the glass transition temperature of epoxy resin
Differential scanning calorimetry analyzes the thermal properties of materials by measuring the heat flow difference between the sample and a reference material.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Differential Scanning Calorimetry for Determining the Melting Point and Glass Transition Temperature of Hot Melt Adhesives
This article introduces the method of determining the melting point and glass transition temperature of hot-melt adhesives using a differential scanning calorimeter. Differential scanning calorimetry analyzes the thermal transition characteristics of materials by measuring the energy difference between the sample and a reference material.
Application of Gardner Colorimeter in the Determination of Oil and Fat Color
The Lovibond tintometer determines the color of oils and fats by visually comparing them with standard glass color standards, with results expressed as numerical codes. During operation, clarified oil samples are poured into the colorimetric cell and compared with color chips under a stable light source.