Liquid cooling constant temperature Bath

The liquid refrigeration constant temperature bath circulates refrigerant through a compressor and adjusts the temperature of the liquid medium with a heater to maintain samples at a stable set temperature. It is used in detection processes requiring precise temperature control, such as paint viscosity testing and ink curing experiments, to ensure result consistency.
Selection
When selecting a liquid cooling thermostatic bath, consider that the temperature range should cover experimental needs, the temperature control accuracy should meet standard requirements, the bath capacity should accommodate sample dimensions, the cooling power should satisfy cooling rate demands, and attention should be paid to medium compatibility and equipment stability.

Terms

Standards

Instruments

Temperature range -20~ 20 ℃, cooling capacity up to 1800W, cooling time is reduced by 35% compared with traditional equipment, open Bath can be applied to acid solution and organic solution thermostatic experiment.

$ 1658.00

Temperature range covers -40 to 100 ℃, Temperature Fluctuation accuracy to +/- 0.05 ℃, resolution up to 0.01 ℃, and supports internal and external double cycle mode to meet the needs of various experiments inside and outside the tank.

$ 1285.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

Temperature control accuracy of +/- 2 ℃, cooling capacity up to 3240W, equipped with fully enclosed Air-Cooled Compressor and anti-corrosion circulation system, rapid temperature rise and fall, support large capacity Bath and external circulation function.

$ 3151.00

The double Compressor cascade refrigeration system is adopted, with fast cooling and low noise, Temperature Fluctuation +/- 0.05 ° C, and pump Flow rate of 8L/min to ensure the uniformity of liquid in the Tank and reliable operation.

$ 1368.00

Temperature range -10~ 100 ℃, Temperature Stability +/- 0.02 ℃, using imported Compressor and SUS304 stainless steel heating device, support internal and external circulation, can accommodate 500ml beaker directly inserted into use.

$ 1361.00

Temperature range -5~ 100 ℃, Temperature Fluctuation Accurate to +/- 0.05 ℃, equipped with circulating pump to support internal and external dual circulation mode, can flexibly meet the temperature control needs of in-tank and out-of-tank experiments.

$ 774.00

Double Compressor cascade refrigeration system is used to achieve rapid cooling, Tank volume 6L with 8L/min pump Flow rate to ensure liquid uniformity, Temperature Fluctuation control within +/- 0.05 ℃, Precision Pt100 Sensor to ensure long-term stable operation.

$ 2203.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, equipped with 6 liter Tank and 8L/min Pump Flow rate, support liquid level alarm and computer communication, the inner Tank and the box are made of high quality stainless steel.

$ 1108.00

Brushless DC motor is used to achieve 0~ 300rpm constant speed oscillation, Temperature range RT +~ 60 ℃ and no drift, rotary oscillation ensures uniform mixing of samples.

$ 740.00

Brushless DC motor to achieve constant speed operation, high temperature control accuracy without drift, Oscillation Frequency 0-300rpm adjustable, swing amplitude 20mm, to meet different experimental needs.

$ 932.00

Brushless DC motor is used to achieve 0~ 300rpm constant speed oscillation, support double mode of rotary and reciprocating, Temperature range RT +~ 60 ℃, with 20mm swing amplitude, suitable for a variety of compounds to foster demand.

$ 932.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, the temperature fluctuation is +/- 0.05 ℃, and it has low water level protection and Compressor multiple protection functions to ensure the safety and stability of the experiment.

$ 1067.00

Articles

Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
The oral dissolving film is uniformly coated by a film applicator and then dried and formed.
Oral dissolving films are prepared by a coating mechanism, where a liquid containing film-forming materials is uniformly applied onto a substrate, followed by drying to remove the solvent and form a solid film.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Surface Tensiometer Evaluates the Wetting and Spreading Properties of Resin Liquids
This article introduces how to use a surface tensiometer to evaluate the wetting and spreading performance of resin liquids. Wetting and spreading affect the adhesion and appearance of products such as coatings and adhesives, and the process can be described by Young's equation and the spreading coefficient.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
Application of Paper Absorbency Tester in Sizing Process
The paper absorbency tester evaluates the absorption performance of paper by measuring the penetration of liquid on the paper. In the sizing process, sizing agents alter the hydrophilicity of the paper fiber surface, thereby affecting the paper's resistance to liquids.
Water Absorption Tester in the Detection of Tissue Paper and Paperboard
This article introduces the application of water absorption testers in the testing of tissue paper and paperboard. The instrument evaluates the water absorption performance of materials by measuring the mass or height of liquid absorbed by the sample, with common methods including the Klemn method and the capillary rise height method.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.