Solution Liquid Density Meter

The liquid density meter for solutions is based on Archimedes' principle, calculating density by measuring the buoyancy force exerted on an object in a liquid. It is used to detect solution concentration, purity, and component ratios, and is applied in the chemical, food, and pharmaceutical industries to control product quality and production processes.
Selection
When selecting, consider the measurement range and accuracy to match the characteristics of the sample. Pay attention to the temperature compensation function to ensure data stability. Ease of operation and calibration methods affect usage efficiency. The corrosion resistance of the material extends the instrument's lifespan, and maintenance costs should align with measurement requirements.

Terms

Standards

Instruments

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, solid and liquid Density testing is supported, and the standard Density kit is easy to operate.

$ 841.00

Density accuracy of 0.001g/cm ³, maximum weighing 310g, built-in a variety of density reference can be customized settings, support solid liquid powder and other sample testing.

$ 525.00

Maximum weighing 210g, density accuracy 0.001g/cm ³, built-in a variety of density reference can be customized settings, support solid and liquid density rack selection, suitable for all kinds of sample density testing.

$ 525.00

High-precision Sensor for 0.01g Readability and 0.001g/cm ³ density accuracy, built-in multiple density references and rigorous calculation programs, supports solid liquid sample testing and directly displays density results.

$ 332.00

The integrated forming large water Tank design has a density accuracy of 0.001g/cm ³, which can quickly measure solids and liquids, support temperature compensation and solution compensation, and is easy and fast to operate.

$ 307.00

Density accuracy of 0.001g/cm ³, maximum weighing 210g, built-in density reference can be customized settings, support solid, liquid, powder and Water Absorbency sample testing, equipped with level indicator and overload alarm function.

$ 525.00

Density direct reading function eliminates the calculation step, can measure solid and liquid density, accuracy of 0.01g, Repeatability +/- 0.01g, all aluminum base design enhances weighing Stability.

$ 415.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeters can be customized, and various measurement modes such as liquid Density are supported.

$ 587.00

Density direct reading function eliminates calculation steps, can measure solid and liquid density, accuracy to three decimal places, equipped with display shield and all aluminum base, enhanced dust and Stability.

$ 680.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, supports liquid Density measurement and custom setting of Density upper and lower limits, and standard RS232 interface is convenient for data transmission.

$ 496.00

The Gamma ball volume replacement method is used to support 0.01-300 g weight range and 0.001g/cm ³ density accuracy, and the immersion depth of the liquid level can be adjusted arbitrarily and the air buoyancy error can be compensated.

$ 875.00

Using the Archimedes principle buoyancy method, the density accuracy is 0.0001g/cm ³, the test time is about 5 seconds, the temperature compensation and solution compensation are supported, and the Draft Shield and RS-232C interface are equipped, which is suitable for on-site rapid measurement.

$ 503.00

Using Archimedes principle buoyancy measurement, density accuracy of 0.001g/cm ³, support 50CC small sample size, equipped with RS-232C interface and battery, can quickly and continuously test various solutions including high viscosity liquids.

$ 317.00

Density direct reading function can avoid cumbersome calculation, equipped with all stainless steel Density bracket, weighing range 120g, accuracy 0.0001g, suitable for a variety of sample testing.

$ 1151.00

The integrated molding large water Tank design can measure large block objects; the density accuracy is 0.001g/cm ³, and the test time is about 5 seconds; it has the function of temperature compensation and solution compensation, and the Draft Shield is suitable for field testing.

$ 359.00

Articles

UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Blade-coating preparation of hole transport layers for perovskite solar cells.
This article introduces the method of preparing the hole transport layer for perovskite solar cells using the doctor-blade coating technique. The doctor-blade coating method involves spreading the solution evenly on the substrate with a blade to form a thin film, making it suitable for large-scale production.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
Tap density tester evaluates the accumulation characteristics of sprayed powder.
This article introduces how to use a tap density tester to evaluate the packing characteristics of spray powders. The tap density tester simulates vibration to densely pack the powder and measures the mass per unit volume, thereby obtaining the tap density.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Paper Thickness Gauge for Determining Paper Thickness and Apparent Density
This article explains how to measure paper thickness and apparent density using a paper thickness gauge. Thickness refers to the vertical distance between the two sides of paper under standard pressure, while apparent density is calculated by dividing the basis weight by the thickness, reflecting the compactness of the paper.
Usage of Paint Film Solvent Rub Tester in Rapid Detection of Curing Degree
The paint film solvent resistance tester rapidly evaluates the degree of paint film curing by simulating solvent wiping. Its principle is that a fully cured paint film has a high cross-linking density, enabling it to resist solvent dissolution.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Salt spray test chamber detects the corrosion resistance of coatings.
The salt spray test chamber accelerates the testing of coating corrosion resistance by simulating a salty and humid environment. It uses atomized sodium chloride solution to form salt spray, which settles inside the constant temperature chamber, and conducts tests under neutral or acidic conditions in accordance with standards.
The role of a reflection densitometer in controlling printing ink concentration.
The reflection densitometer measures the light reflectance of the ink layer and converts it into a density value, thereby objectively reflecting the thickness and concentration of the ink layer. In printing, it is used to monitor solid density, ensuring stable ink supply, replacing subjective judgment, and enabling data-driven control.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Applicable Scenarios for Neutral Salt Spray and Copper-Accelerated Acetic Acid Salt Spray Tests
Neutral salt spray testing and copper-accelerated acetic acid salt spray testing are both accelerated methods used to evaluate the corrosion resistance of materials, simulating saline environments to predict long-term performance. The neutral salt spray test uses a neutral sodium chloride solution, which causes relatively mild corrosion and is suitable for general metals and coatings, such as automotive parts.
When to use three-point calibration versus two-point calibration for pH meters?
The calibration of a pH meter is performed to determine the actual zero potential and slope of the electrode, enabling accurate measurement of the acidity or alkalinity of a solution. Two-point calibration is commonly used for daily measurements within a narrow range, while three-point calibration is employed for higher accuracy requirements.