Eddy-Current Conductivity Meter

The eddy current conductivity meter operates on the principle of electromagnetic induction. The probe generates an alternating magnetic field, which induces eddy currents in metallic materials. By measuring the impedance changes caused by these eddy currents, the conductivity is calculated. It is used to assess the conductive properties of metallic materials, evaluate the treatment effectiveness of metal substrates in the coatings and inks industry, and monitor the distribution of fillers in the plastics industry.
Selection
Select the probe frequency based on the type and thickness of the material being tested: use high frequency for thin metallic materials and low frequency for thick alloy materials. Consider the measurement range to cover common metal conductivity values. The environment should be protected from strong electromagnetic interference. Portable devices are suitable for on-site inspections, while benchtop devices are ideal for fixed measurements in the laboratory. The probe size should match the curvature of the test surface.

Terms

Standards

Instruments

Using magnetic Induction and eddy Current principle, Measurement range 0~ 1250μm, error +/- 3%, support Bluetooth transmission and automatic identification of matrix material, suitable for one-handed operation.

$ 564.00

Measurement range of 0-1250 μm using eddy Current principle, single continuous dual mode and large Probe design, support Automatic calibration matrix recognition, error of only +/- 3% resolution up to 0.1 μm.

$ 320.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 2000µm, error +/- 1~ 3%, with automatic identification of matrix material and memory Adjustment, support split Probe to enhance mobility.

$ 338.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 1250μm, error +/- 3%, support single and continuous Measurement mode, automatic identification of matrix material and memory calibrated value, easy to operate.

$ 401.00

Using eddy Current Measurement principle, Measurement range 0~ 1250μm, with continuous single double Measurement mode, metal shell anti-interference, support automatic statistics and storage of 1560 measured values.

$ 344.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 500μm, resolution of 0.1μm, wear-resistant hard metal probe and Automatic calibration function, support USB data communication.

$ 275.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 500um, resolution 0.1μm, wear-resistant hard metal probe and Automatic calibration function, support single and continuous Measurement mode.

$ 275.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0~ 1250μm, resolution of 0.1μm, equipped with wear-resistant hard metal probe, support 99 sets of Data storage and statistical calculation functions.

$ 525.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-2000μm, resolution up to 0.1μm, with automatic identification of substrate function and Data storage ability, support surface measurement minimum convex 1.5mm.

$ 419.00

Using magnetic Induction and eddy Current dual thickness measurement method, Measurement range 0-1500 μm, resolution 0.1 μm, support continuous and single measurement, with statistical function and 500 sets of data storage.

$ 264.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-1250μm, support continuous single two Measurement mode, with automatic statistics and storage function, metal shell anti-interference.

$ 425.00

Using magnetic Induction and eddy Current principle, Measurement range 0~ 500μm, resolution 10μm, wear-resistant hard metal probe and Automatic calibration memory function, support USB data communication and automatic shutdown.

$ 240.00

Using eddy Current Measurement principle, Measurement range 0~ 1250μm, resolution 0.1μm, with 500 sets of Data storage, over limit alarm and automatic shutdown function, split Probe design is easy to operate on site.

$ 280.00

Integrated magnetic Induction and eddy Current dual technology, automatic identification of the substrate and conversion, Measurement range 0-1500μm, accuracy +/- 2%, Probe life more than 500,000 times, adapt to complex environment.

$ 227.00

Using magnetic Induction and eddy Current dual principle, Measurement range 0-1500μm, support continuous single two Measurement mode, with 500 sets of data storage and thermal printing function, the error is only +/- 3%.

$ 385.00