Liquid Solution ColoriMeter

A solution colorimeter measures the spectral difference between the transmitted light and a standard color by illuminating a solution sample with a light source, and calculates the color difference value. It is used to detect the color consistency of liquids and monitor product quality in industries such as dyes and beverages.
Selection
When selecting, consider matching the measurement aperture to the sample container size, review the instrument's repeatability indicators, and confirm support for current color standards. Verify the instrument's measurement range based on common solution types, and evaluate whether the operational interface aligns with usage habits.

Terms

Standards

Instruments

Adapted to NS series ColoriMeter, it can measure liquid, sauce and powder samples, realize color data collection of various forms of materials, and expand the application range of the instrument.

$ 557.00

The general ion standard solution concentration is 1000ppm, using PTFE solution bottle Encasement, size 190 × 65mm, 500g per bottle, suitable for daily calibrating needs.

$ 135.00

The composite design can be filled with internal reference solution, equipped with annular ceramic liquid junction and circular Glass sensitive film, Measurement range 0-14pH, Operating temperature 0-80 ℃, to ensure long-term measurement Stability.

$ 143.00

General ion standard solution with a concentration of 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating needs.

$ 135.00

General ion standard solution with concentration 1000ppm, PTFE solution bottle Encasement, capacity 480mL, suitable for daily calibrating needs.

$ 135.00

Supports more than 30 chroma indicators, Measurement accuracy ≤ E * ab ≤ 0.01, single measurement only takes 1.5 seconds, minimum liquid addition is as low as 1ml, equipped with thermostatic sample tank and 7 inch Touchscreen.

$ 4075.00

General ion standard solution with a concentration of 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating needs.

$ 135.00

General ion standard solution concentration 1000ppm, suitable for daily ion calibrating, PTFE solution bottle Encasement, capacity 480mL, water Hardness type.

$ 135.00

The general ion standard solution concentration is 1000ppm, using PTFE solution bottle Encasement, size 190 × 65mm, 500g per bottle, suitable for daily ion calibrating.

$ 135.00

The general ion standard solution concentration is 1000ppm, using PTFE solution bottle Encasement, size 190 × 65mm, 500g per bottle, suitable for daily calibrating needs.

$ 135.00

Built-in temperature resistor real-time sensing sample temperature, gel KCL reference solution to ensure long-term stability of ElectRode, Measurement range 0~ 14pH, suitable for a variety of liquid environments.

$ 96.00

Using open liquid complex structure, equipped with solid polymer reference electrolysis solution, the membrane resistance is less than 200MΩ, suitable for -5~ 80 ℃ wide temperature environment, to ensure long-term stable measurement.

$ 243.00

Concentration 1000ppm of copper ion standard solution, PTFE bottle Encasement, capacity 480mL, suitable for daily ion calibrating applications.

$ 135.00

Concentration 1000ppm, Encasement with PTFE solution bottle, capacity 480mL, suitable for daily ion calibrating, to ensure measurement accuracy and Stability.

$ 135.00

The pRoduct concentration 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating, to ensure measurement accuracy.

$ 135.00

Articles

UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Colorimeter controls batch color difference in plastic and rubber films.
This article primarily discusses how to use a colorimeter to control color differences in the production of plastic and rubber films. It explains the working principle of the colorimeter, which involves converting colors into numerical values represented by L, a, and b values, and then calculating the color difference.
Blade-coating preparation of hole transport layers for perovskite solar cells.
This article introduces the method of preparing the hole transport layer for perovskite solar cells using the doctor-blade coating technique. The doctor-blade coating method involves spreading the solution evenly on the substrate with a blade to form a thin film, making it suitable for large-scale production.
The coating machine applies the OLED light-emitting layer onto ITO glass.
This article introduces the technique of using a coating machine to apply OLED luminescent layers onto ITO glass. The coating principle involves matching solution rheology with substrate surface energy, allowing control over film thickness by adjusting parameters such as viscosity and speed.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
Colorimeter evaluates the change in yellowing index of transparent resin.
This article introduces how to use a colorimeter to measure the yellowing index changes in transparent resin. Transparent resin can turn yellow over time or due to environmental influences, and the yellowing index can quantify the degree of color change.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.
Application of Colorimeters in Color Management for Packaging and Printing
This article mainly discusses the application of colorimeters in color management for packaging and printing. A colorimeter is an instrument used to measure color, capable of converting colors into numerical values, such as representing them with L*a*b* values.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
Salt spray test chamber detects the corrosion resistance of coatings.
The salt spray test chamber accelerates the testing of coating corrosion resistance by simulating a salty and humid environment. It uses atomized sodium chloride solution to form salt spray, which settles inside the constant temperature chamber, and conducts tests under neutral or acidic conditions in accordance with standards.
Multi-angle colorimeter detects color changes in pearlescent coatings.
Pearlescent coatings contain special flake pigments that produce color effects that vary with the viewing angle, known as "goniochromism." Traditional single-angle measurements struggle to accurately capture this characteristic.
Application of Colorimeters in Controlling Color Differences in Paint Batches
This article introduces the role of colorimeters in controlling color consistency in paint production. Since human judgment of color is easily influenced by lighting and subjective factors, colorimeters quantify color differences in the CIELAB color space by measuring spectral data, providing an objective basis for production.
UV-Vis Spectrophotometer Measures Ink Pigment Concentration
This article introduces the method of measuring the concentration of ink pigments using a UV-Vis spectrophotometer. The principle is based on the Lambert-Beer law, which calculates the concentration by measuring the absorbance of the pigment solution at specific wavelengths.
Applicable Scenarios for Neutral Salt Spray and Copper-Accelerated Acetic Acid Salt Spray Tests
Neutral salt spray testing and copper-accelerated acetic acid salt spray testing are both accelerated methods used to evaluate the corrosion resistance of materials, simulating saline environments to predict long-term performance. The neutral salt spray test uses a neutral sodium chloride solution, which causes relatively mild corrosion and is suitable for general metals and coatings, such as automotive parts.