Calcium Powder Whiteness Tester

The calcium powder whiteness meter measures the surface light reflectivity of a sample through reflection spectroscopy and compares it with a standard whiteboard to determine the whiteness value. It is used to detect the whiteness quality of powder materials such as calcium carbonate, and to control the consistency of raw materials and product appearance in industries like papermaking and coatings.
Selection
When selecting, ensure the measurement aperture matches the sample particle size, and the calibration plate must have a national metrology certificate. Consider the impact of powder compaction density on readings, and the instrument should have automatic compensation functionality. Avoid direct exposure to strong light in the working environment, and regularly verify stability using a standard white plate.

Terms

Instruments

Can measure ISO blue light whiteness and fluorescence whiteness, support powder whiteness measurement, Repeatability ≤ 0.02, built-in thermal printer, data can be cached and power-off protection, equipped with RS232 interface for easy communication.

$ 1051.00

Can measure ISO whiteness and fluorescence whiteness, Repeatability ≤ 0.02, support data cache and power-off protection, equipped with RS232 interface for easy communication, suitable for powder and flake samples.

$ 953.00

Designed for Calcium Composite ElectRode, 250ml Standard Encasement is provided to ensure ElectRode calibrating accuracy and long-term Stability for a variety of analytical scenarios.

$ 110.00

Fully automatic one-click measurement of a variety of whiteness paraMeters, support chromaticity coordinates ≤ 0.001 High Accuracy, built-in thermal printer and RS232 interface, suitable for powder, paper and other samples.

$ 1818.00

Using R457 whiteness formula, blue light whiteness and fluorescence whiteness can be measured simultaneously, Repeatability ≤ 0.3, Operating temperature 5~ 35 ℃, optical path design is simple to ensure measurement accuracy and Repeatability.

$ 432.00

Repeatability of 0.2 for measurement of diffuse reflection factor using 457 nm blue wavelength can detect Fluorescent Whitening Agent and calculate fluorescence whiteness value, which is suitable for surface whiteness analysis of various materials.

$ 554.00

Can measure ISO whiteness and fluorescence whiteness, equipped with diffuse ball diaMeter 150mm, test hole 19mm, support light scattering coefficient, absorption coefficient and other Optical inspection paraMeters, suitable for a variety of material surface whiteness analysis.

$ 1174.00

It can measure the blue light diffuse reflection factor (R457) and fluorescence whiteness, use d/o illumination observation geometry conditions, test hole diaMeter 30mm, can analyze whether the material contains fluorescent whitening agent and measure a variety of Optical inspection coefficients.

$ 1348.00

Adopt LED Illuminant and 45/0 illumination conditions, measurement aperture Φ 15mm, resolution 0.1, Repeatability ≤ 0.3, AC-DC dual-use design is convenient for on-site rapid detection of whiteness value.

$ 233.00

Using LED Illuminant and 45/0 illumination conditions, Measurement range 0~ 199.9, resolution 0.1, can detect Fluorescent Whitening Agent and measure increased whiteness, Repeatability ≤ 0.3.

$ 417.00

Measurement time is only 1.5 seconds, Repeatability is less than R0.1, which can measure a variety of whiteness indicators and reflectance, and is suitable for the analysis of fluorescent whitening samples.

$ 800.00

R457 blue light whiteness formula, Measurement range 0~ 199.9%, resolution 0.1, Basis Weight measurement of whiteness of fluorescent whitening objects and paper Opacity, suitable for a variety of materials surface flat samples.

$ 332.00

Adopt simple light path design and activity platform to effectively avoid light leakage; Measurement range 0~ 100%, Precision 0.1; Use D65 Illuminant and R457 whiteness formula to ensure stable and reliable measurement.

$ 428.00

Using LED Illuminant, 45/0 illumination conditions, Measurement range 0~ 199.9, Repeatability ≤ 0.3, suitable for whiteness measurement of white objects or powders, easy to carry and on-site detection.

$ 393.00

Geometry conditions were observed using d/o illumination, and the diaMeter of the diffuse sphere was 150mm, which can measure the diffuse reflection factor of blue light and the fluorescence whiteness, and support Multi-ParaMeter analysis such as Opacity and light scattering coefficient.

$ 1300.00