PCT Test Chamber

The PCT test chamber simulates high temperature and high humidity conditions by pressurizing a saturated steam environment, accelerating the aging process of materials. It is used to test the moisture and heat resistance of electronic components, coatings, and other products, verifying their reliability under extreme environmental conditions.
Selection
Focus on core parameters such as a temperature range of 100-150℃, humidity of 100% RH, and pressure of 0.1-0.3 MPa. Determine the inner chamber volume based on the size of the test samples, and check the safety protection devices and control system accuracy to ensure compliance with relevant industry standards.

Terms

Standards

Instruments

The circular stainless steel liner is used to prevent condensation and dripping, the copper tube bell mouth is designed with good air tightness and low water consumption, and the special high temperature foaming material improves the pressure life. It is equipped with a 16L large-capacity water Tank and an automatic water replenishment system.

$ 4269.00

The stainless steel mirror heating Chamber and intermittent continuous heating technology are used to heat the sample evenly, with a heat-resistant temperature of more than 200 ° C. Equipped with HBM Sensor, it can remember multiple sets of drying processes and support three heating modes.

$ 612.00

The digital display temperature control is accurate and reliable, the hot air circulation system is composed of a high temperature fan and a suitable air duct to improve the Temperature uniformity in the working room, and the heating wire is installed at the bottom to heat up quickly.

$ 2171.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.

$ 13209.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, humidity control 30~ 98% RH, using French Taikang Compressor and multi-wing air supply circulation system to ensure uniform and stable distribution of temperature and humidity.

$ 12531.00

Inner Chamber dimensions 800 * 1000 * 1000mm, temperature range -20~ 150 ℃, humidity range 30~ 98% R.H., using French Taikang Compressor and multi-wing air supply circulation, uniform temperature and humidity distribution, high control accuracy.

$ 9191.00

The transparent vacuum chamber is sturdy and durable, and the automatic constant pressure air supply ensures the stability of the preset Vacuum Level. The range of Vacuum Level is 0~ -90KPa, and the test process is automatically completed with one-click operation, without the need for an external vacuum pump.

$ 877.00

The rectangular vacuum Chamber improves space utilization, the stainless steel studio is durable and easy to clean, the Vacuum Level is 133Pa, the double-decked tempered Glass door is easy to observe, and the optional program control ensures the stoving conformity.

$ 3294.00

The rectangular vacuum Chamber improves space utilization, Vacuum Level up to 133Pa, is equipped with double-decked tempered Glass doors for easy observation, supports program control of heating and vacuum holding time, and improves processing conformity.

$ 2939.00

Rectangle vacuum Chamber improves space utilization, stainless steel studio is durable and easy to clean, double-decked tempered Glass door is easy to observe, Vacuum Level 133Pa, temperature control accuracy +/- 1 ℃, optional program control to ensure stoving conformity.

$ 16559.00

The rectangular vacuum Chamber improves space utilization, the stainless steel studio is durable and easy to clean, the Vacuum Level 133Pa ensures efficient handling, double-decked tempered Glass doors are easy to observe, and over-temperature protection enhances safety.

$ 4222.00

The adapter adopts stainless steel sample Chamber removable cleaning, the temperature control accuracy of water Bath jacket reaches 0.1 ℃, the sample volume is only 2-16 ml, and the Measurement range covers 2-26600000MPas/cp.

$ 2300.00

Equipped with two sets of Compressor automatic switching to ensure long-term continuous operation, support 30-stage programming control Humidity Illumrination degree, light intensity 0~ 12000LX six-level adjustable, mirror stainless steel liner for easy cleaning and disinfection.

$ 2447.00

With two sets of Compressor automatic switching, support for long-term continuous operation; programmable control of temperature, Humidity, Illumrination degree and time, simulate natural conditions; Illumrination degree automatic detection, reduce errors, suitable for plant growth research.

$ 3097.00

Adopt all stainless steel mirror heating Chamber and precision casting aluminum shell, heat resistance above 200 ℃, equipped with HBM imported Sensor, support three heating modes, maximum weighing 110g, reading accuracy 0.005g.

$ 688.00

Articles

Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Ozone Aging Test Chamber Evaluates Rubber SAE J2527 Cracking
This article introduces how to use an ozone aging test chamber to evaluate the cracking problem of rubber caused by ozone when used outdoors.
UV aging test chamber for testing plastic weather resistance according to ISO 4892-2.
This article introduces the method of testing the weather resistance of plastics using a UV aging test chamber in accordance with the ISO 4892-2 standard.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.