Color Density Tester

The color density tester calculates the degree to which color absorbs light by measuring the intensity of light reflected or transmitted from the surface of an object. It is used for monitoring ink layer thickness in printed materials and detecting color differences in plastic products, ensuring batch color consistency.
Selection
Choose transmission or reflection type based on the morphology of the measured object; consider the reflective characteristics of the substrate to match the optical structure; verify that the instrument's measurement aperture is compatible with the sample size; ensure the measurement range covers the density range specified by industry standards; select a model with ambient light compensation functionality.

Terms

Standards

Instruments

Adopt horizontal press measurement and physical positioning observation window, density Repeatability ≤ 0.001D, chroma Repeatability dE * ab ≤ 0.03, provide nearly 30 kinds of Measurement parameters and more than 30 kinds of evaluation Illuminants, and support connection PC software and mobile end applications.

$ 3285.00

Density accuracy of 0.001g/cm ³, maximum weighing 210g, built-in a variety of density reference and accurate calculation program, support overload alarm and level indication, optional communication serial port and windshield.

$ 525.00

7 inch wireless split structure to achieve long-distance control, density Measurement range coverage > 1 and < 1, readability of 0.0001g/cm ³, support for a variety of liquid types and fast measurement, easy and durable operation.

$ 627.00

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading response time is less than 3 seconds, standard Density kit is easy to install, supports a variety of weighing units and RS232 data output.

$ 1022.00

High Accuracy Electromagnetic Force Sensor, Density Direct Reading Response Time Less Than 3 Seconds, Standard Density Weighing Kit, Support for Various Weighing Units, Capacity 320g readability 0.001g.

$ 887.00

The new generation of Electromagnetic Force Sensor ensures stable weighing, Density direct reading response time is less than 3 seconds, standard Density kit is easy to install, and supports a variety of weighing units and down hooks for special applications.

$ 977.00

High Accuracy Electromagnetic Force Sensor, repeatability error +/- 0.002g, Density direct reading reaction time < 3S, standard Density weighing kit, supports a variety of weighing units and lower hook design.

$ 932.00

Maximum weighing 210g, density accuracy 0.001g/cm ³, built-in a variety of density reference can be customized settings, support solid and liquid density rack selection, suitable for all kinds of sample density testing.

$ 525.00

High Accuracy weighing system with density accuracy of 0.001g/cm ³, maximum weighing of 210g, built-in density reference program, support for solid and liquid density testing, equipped with level indicator and overload alarm function.

$ 525.00

Density direct reading function can avoid cumbersome calculation, equipped with all stainless steel Density bracket, weighing range 120g, accuracy 0.0001g, suitable for a variety of sample testing.

$ 1151.00

With 0.001g/cm ³ density accuracy and 0.001g weighing accuracy, it supports solid, liquid, powder and Water Absorbency sample testing, and has built-in multiple density reference and direct density display functions.

$ 525.00

Density direct reading function eliminates cumbersome calculations, equipped with all stainless steel Density bracket, weighing range 200g, accuracy 0.001g, suitable for a variety of sample tests.

$ 546.00

Electromagnetic Force Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, solid and liquid Density testing is supported, and the standard Density kit is easy to operate.

$ 841.00

High Accuracy Sensor is used to ensure stable weighing, Density direct reading reaction time is less than 3 seconds, Density upper and lower limits and specific gravity paraMeters can be customized, and solid Density, volume and metal purity measurement are supported.

$ 716.00

High-precision Sensor for 0.01g Readability and 0.001g/cm ³ density accuracy, built-in multiple density references and rigorous calculation programs, supports solid liquid sample testing and directly displays density results.

$ 332.00

Articles

Application of Flexographic Proofing Press in Evaluating Color Reproducibility of Flexographic Inks
This article primarily discusses the use of a flexographic proofer to evaluate the color reproducibility of flexographic inks. It introduces the role of the proofer in simulating production conditions and explains how to prepare samples by setting parameters such as pressure, speed, and anilox roll specifications.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Colorimeter controls batch color difference in plastic and rubber films.
This article primarily discusses how to use a colorimeter to control color differences in the production of plastic and rubber films. It explains the working principle of the colorimeter, which involves converting colors into numerical values represented by L, a, and b values, and then calculating the color difference.
Colorimeter evaluates the change in yellowing index of transparent resin.
This article introduces how to use a colorimeter to measure the yellowing index changes in transparent resin. Transparent resin can turn yellow over time or due to environmental influences, and the yellowing index can quantify the degree of color change.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
Tap density tester evaluates the accumulation characteristics of sprayed powder.
This article introduces how to use a tap density tester to evaluate the packing characteristics of spray powders. The tap density tester simulates vibration to densely pack the powder and measures the mass per unit volume, thereby obtaining the tap density.
Paper Thickness Gauge for Determining Paper Thickness and Apparent Density
This article explains how to measure paper thickness and apparent density using a paper thickness gauge. Thickness refers to the vertical distance between the two sides of paper under standard pressure, while apparent density is calculated by dividing the basis weight by the thickness, reflecting the compactness of the paper.
Usage of Paint Film Solvent Rub Tester in Rapid Detection of Curing Degree
The paint film solvent resistance tester rapidly evaluates the degree of paint film curing by simulating solvent wiping. Its principle is that a fully cured paint film has a high cross-linking density, enabling it to resist solvent dissolution.
Application of Colorimeters in Color Management for Packaging and Printing
This article mainly discusses the application of colorimeters in color management for packaging and printing. A colorimeter is an instrument used to measure color, capable of converting colors into numerical values, such as representing them with L*a*b* values.
Standardized ink color evaluation environment for visual color comparison cabinets
This article introduces the standardized application of visual color comparison boxes in ink color evaluation. It emphasizes that to ensure the accuracy and consistency of color judgments, the evaluation environment must be strictly controlled.
Multi-angle colorimeter detects color changes in pearlescent coatings.
Pearlescent coatings contain special flake pigments that produce color effects that vary with the viewing angle, known as "goniochromism." Traditional single-angle measurements struggle to accurately capture this characteristic.
The role of a reflection densitometer in controlling printing ink concentration.
The reflection densitometer measures the light reflectance of the ink layer and converts it into a density value, thereby objectively reflecting the thickness and concentration of the ink layer. In printing, it is used to monitor solid density, ensuring stable ink supply, replacing subjective judgment, and enabling data-driven control.
Application of Colorimeters in Controlling Color Differences in Paint Batches
This article introduces the role of colorimeters in controlling color consistency in paint production. Since human judgment of color is easily influenced by lighting and subjective factors, colorimeters quantify color differences in the CIELAB color space by measuring spectral data, providing an objective basis for production.
The role of spectrophotometers in ink color matching
The spectrophotometer objectively quantifies color by measuring the spectral data of ink. Based on the Lambert-Beer law, it converts color into calculable spectral values, replacing traditional methods that rely on the human eye and experience.