Halogen Moisture Gauge

The halogen moisture analyzer uses a halogen lamp to heat the sample, causing moisture to evaporate. The moisture content is calculated by measuring the mass difference before and after heating using a weighing sensor. It is used for rapid determination of moisture in materials such as coatings and plastics, offering simple operation and intuitive results.
Selection
When selecting a halogen moisture analyzer, it is essential to consider matching the heating temperature range with the sample characteristics, verify that the weighing accuracy meets testing requirements, examine the ease of instrument calibration and maintenance, assess whether the operation interface aligns with user habits, and compare the consumable costs of different models.

Terms

Standards

Instruments

Using an annular halogen lamp to heat uniformly, the sample is rapidly dried in just a few minutes, the moisture measurement range is 0.00 to 100%, and 9 paraMeters including water loss rate and temperature can be displayed.

$ 344.00

Ring halogen lamp heating, 0.02% moisture readability, RT +~ 180 ℃ Temperature range, automatic measurement, Draft Shield design, pure stainless steel heating Chamber cover, 16 sets of Data storage.

$ 503.00

The annular halogen lamp is used to heat the sample evenly and quickly, and the surface is not easily damaged. Capacity 100g, moisture measurement range 0.00~ 100%, and the general sample can be measured in a few minutes.

$ 388.00

It adopts annular halogen lamp heating and multi-layer stainless steel heating Chamber, heating up fast and uniform, moisture measurement accuracy of 0.1%, equipped with German imported Sensor to ensure stable weighing, support data storage and printing functions.

$ 1124.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

Using halogen lamp heating technology, Capacity 110g, moisture readability 0.02%, with RS232C Communication interface, Heating Temperature range RT +~ 200 ℃, suitable for rapid drying analysis of various samples.

$ 420.00

Using annular halogen lamp heating, heating fast and uniform, Heating Temperature range RT + 40~ 199 ℃, moisture accuracy of 0.1%, with imported Sensor to ensure stable weighing, support data storage and printing.

$ 814.00

Using halogen lamp heating technology, Capacity 110g, temperature adjustment accuracy +/- 1 ℃, rapid drying of samples and real-time display of moisture percentage, suitable for a variety of sample detection.

$ 483.00

The annular halogen lamp is uniformly heated, Capacity 50g, moisture measurement range 0.00-100%, heating temperature can reach 160 ℃, the general sample can be measured in just a few minutes, and the detection efficiency is high.

$ 388.00

The annular halogen lamp uniformly heats the sample, Capacity 50g, Moisture measurement range is 0.00~ 100%, and the measurement is completed within a few minutes. The results are consistent with the Oven method and the efficiency is higher.

$ 319.00

Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.

$ 399.00

Using halogen lamp heating source and German HBM Sensor, moisture readability of 0.01%, Repeatability ≤ +/- 0.2%, support 0~ 100% moisture measurement range, suitable for a variety of sample states such as powder and liquid.

$ 564.00

Using halogen lamp heating technology, Capacity 110g, readability 0.001g, heating temperature up to 200 ° C, fast drying and real-time display of moisture percentage, suitable for a variety of sample analysis.

$ 566.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Articles

Comparison Between Halogen Moisture Analyzer and Karl Fischer Moisture Analyzer in Plastic Moisture Detection
This article compares the differences between halogen moisture analyzers and Karl Fischer moisture analyzers in detecting moisture in plastics.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.