Rubber Sheet Coating Thickness Gauge

The rubber coating thickness gauge operates on the principle of magnetic induction or eddy current. The probe contacts the coating, generating changes in the electromagnetic field to calculate the thickness. It is used to measure the thickness of coatings on rubber and plastic substrates, and for quality control in the production of tires and rubber rollers.
Selection
When selecting, consider matching the measurement principle with the substrate type: magnetic induction is suitable for ferrous bases, while eddy current is suitable for non-ferrous bases. Ensure the measurement range covers the thickness of the sample, and the probe size fits the measured curved surface. Pay attention to the instrument's calibration method and its ability to resist environmental interference.

Terms

Instruments

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Travel 0-1.25 mm, measurement error +/- 1HAM, pressure at the end of the needle 324-764mN, suitable for thin rubber samples with a thickness of 1.5mm or more, and can be used with a fixed load measuring rack.

$ 1122.00

Measurement thickness up to 25mm with an error of only +/- 3% with removable FJS Probe for thick protective coating substrates, statistical capabilities and 250,000 Data storage capabilities.

$ 2115.00

Measurement accuracy with professional calibrating services for quality control and equipment maintenance, purchased with Coating thickness Gauge.

$ 154.00

Measurement range 0-20mm, accuracy 0.001mm, contact pressure 20 +/- 5kPa, suitable for paper, Cardboard and sheet material Film thickness detection, in line with a number of international standards.

$ 401.00

Measurement thicknesses up to 25mm with an error of only +/- 3% and a removable FJS Probe for thick protective coating measurements, supporting 1000 Data storage and statistical functions.

$ 1597.00

Measurement of nonmagnetic coatings on ferrous metals, thickness range 0-6000μm, accuracy +/- 3%, built-in Probe single-handed operation, Protection Rating IP65, 60 + readings per minute.

$ 1022.00

Measurement range 0~ 12.7mm, resolution up to 0.001mm, contact pressure 20 +/- 0.5Kpa to ensure measurement Stability, suitable for all kinds of sheet material thickness detection.

$ 543.00

Travel 0-1.25 mm, measurement error +/- 1HAM, suitable for thin rubber samples with a thickness of 1.5mm or more. Sensitivity is high, and it needs to be used with a constant load measuring rack to ensure Precision.

$ 921.00

Adopt magnetic Induction principle measurement, thickness range 0~ 1000μm, error +/- 3%, with low voltage prompt function, support split Probe and customized range, adapt to different curvature matrix measurement needs.

$ 243.00

Measurement principle using ultrasonic, Measurement range 50~ 3800μm, accuracy +/- (2μm + 3%), suitable for concrete and fiberglass substrate Coating thickness detection.

$ 2939.00

Measurement principle using ultrasonic, Measurement range 13~ 1000μm, accuracy +/- (2μm + 3%), suitable for wood, plastic and other substrates polymer Coating thickness detection.

$ 2652.00

Suitable for medium hard resilience, rubber or microporous materials, Measurement range 0-100HE, more suitable for thinner or curved samples, can be used with handheld or supporting bench.

$ 183.00

Articles

Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.
Differences in Measurement Principles Between Magnetic Method and Eddy Current Method for Coating Thickness Gauges
Coating thickness gauges primarily utilize two measurement principles: magnetic method and eddy current method. The selection of the method should be based on the characteristics of the substrate material to ensure measurement accuracy.
What is a Coating Thickness Gauge? A Complete Analysis of Its Principles, Usage, and Application Areas
The article systematically elaborates on the working principles of two core measurement techniques, magnetic induction and eddy current, detailing the standard measurement process from calibration to data recording, and conducting an in-depth analysis of the influence of substrate characteristics, geometric shapes, and environmental factors on measurement accuracy.