High and Low Temperature Circulation Bath

The high and low temperature circulating bath controls the temperature of the liquid inside the tank through refrigeration and heating systems, cycling within a set temperature range. It is used for testing the performance of materials under alternating temperature conditions, such as aging experiments for electronic components and stability testing of chemical samples.
Selection
When selecting, consider that the temperature range covers experimental needs, temperature control accuracy meets standards, tank volume matches sample size, heat transfer medium is compatible with experimental materials, equipment stability meets continuous operation duration, and the operating interface aligns with user habits.

Terms

Standards

Instruments

Temperature range of -25~ 200 ℃ and +/- 0.01 ℃ high resolution, support internal and external circulation and horizontal and vertical two-way mixing, equipped with low level protection and Pt100 temperature sensor, suitable for multi-sample thermostatic testing needs.

$ 1752.00

The centrifugal circulation pump without heat is adopted to reduce the influence of temperature field, and the U-type reflux circulation realizes Temperature Uniformity +/- 0.05 ℃. It has safety devices such as power-off protection and low water level alarm, and can choose multi-stage temperature control program.

$ 1222.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, and the U-shaped return design realizes Temperature Uniformity +/- 0.0050 ℃, with low water level protection and Compressor multiple safety protection functions.

$ 7243.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity +/- 0.0050 ℃, with low water level protection and temperature runaway alarm and other safety functions, accurate and stable temperature control.

$ 1703.00

Temperature range -30~ 25 ℃, Temperature Stability +/- 2 ℃, equipped with fully enclosed Air-Cooled Compressor and anti-corrosion circulation system, high temperature lifting speed, can provide large Flow rate circulation and multi-functional low temperature operation support.

$ 2541.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ℃, with low water level protection and anti-dry burning functions, to ensure the safe and stable operation of the experiment.

$ 1335.00

8L Tank with -10~ 100 ℃ wide Temperature range, equipped with maintenance-free pressure pump to achieve two-way mixing, support single point and two point temperature calibrating, with low level protection and high temperature protection function.

$ 1122.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity +/- 0.0050 ℃, integrated PID automatic temperature control and High Accuracy PT100 Sensor to ensure stability and accuracy.

$ 1408.00

With heating and cooling function, Temperature range -10~ 150 ℃, Temperature Fluctuation +/- 0.05~ 0.1 ℃, Pump Flow rate 12L/min, Support internal and external circulation and remote communication, corrosion resistant design.

$ 974.00

Using non-fluorine environmental protection Compressor refrigeration, Temperature Uniformity up to +/- 0.05 ℃, equipped with High Accuracy PT100 Sensor. The domestic circulation system avoids the heat generation of the water pump from affecting the temperature field, supports multi-capacity optional, Safety protection functions are complete.

$ 1264.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, integrates PID automatic temperature control program, Temperature Uniformity +/- 0.0050 ℃, and has multiple safety functions such as low water level protection and temperature loss alarm.

$ 1416.00

8L Tank Volume, Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 0.01~ 0.05 ℃, with low liquid level protection and automatic power failure recovery function, support internal and external circulation operation.

$ 1542.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field. Temperature Uniformity reaches +/- 0.0050 ° C. It has safety functions such as low water level protection and temperature runaway alarm to ensure the stability and reliability of the experimental process.

$ 6070.00

Temperature range -30~ 100 ℃, temperature resolution 0.1 ℃, fully enclosed Compressor refrigeration and overheating overcurrent protection, stainless steel liner for easy cleaning, equipped with high-performance heat-free centrifugal circulation pump.

$ 1493.00

The non-heat centrifugal circulating pump is adopted to avoid its own heat generation affecting the temperature field. The U-shaped return design realizes Temperature Uniformity +/- 0.0050 ℃, and has multiple safety devices such as low water level protection and temperature loss alarm.

$ 5621.00

Articles