Temperature Chamber

The temperature chamber controls the internal temperature through a heating and cooling system to simulate the state of products in different temperature environments. It is used to detect the performance changes of materials under high temperature, low temperature, or alternating temperature conditions, commonly employed in aging tests and quality control for electronic components and chemical materials.
Selection
When selecting a temperature chamber, consider the size of the tested object to determine the volume range, determine the temperature range and fluctuation based on the test standards, select the compressor power according to the test duration, choose the chamber material based on the usage scenario, and verify whether the sample shelf load capacity and power supply configuration meet the requirements.

Terms

Standards

Instruments

The digital display temperature control is accurate and reliable, the hot air circulation system is composed of a high temperature fan and a suitable air duct to improve the Temperature uniformity in the working room, and the heating wire is installed at the bottom to heat up quickly.

$ 2171.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.

$ 13209.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, humidity control 30~ 98% RH, using French Taikang Compressor and multi-wing air supply circulation system to ensure uniform and stable distribution of temperature and humidity.

$ 12531.00

Inner Chamber dimensions 800 * 1000 * 1000mm, temperature range -20~ 150 ℃, humidity range 30~ 98% R.H., using French Taikang Compressor and multi-wing air supply circulation, uniform temperature and humidity distribution, high control accuracy.

$ 9191.00

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and identification inspection.

$ 8497.00

Temperature range -20~ 100 ℃, Temperature resolution 0.1 ℃, using TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuations, with 100 sets of program capacity and a variety of Safety protection functions.

$ 4419.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.

$ 6254.00

Temperature range -20~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, using a unique equilibrate temperature control method to achieve high-precision stable control, the studio is made of 304 stainless steel.

$ 6421.00

Temperature range -20~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature, low temperature and constant temperature test, suitable for Reliability test, equipped with multiple protection devices and safety system.

$ 4818.00

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high and low temperature cycle change test, suitable for material performance inspection and aging test, equipped with multiple safety protection devices.

$ 6431.00

Adopt unique equilibrate temperature control method to achieve high precision temperature control, temperature range -40~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, the studio is made of 304 stainless steel.

$ 6563.00

Temperature range -20~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature cycle change test, suitable for aging test and material performance inspection.

$ 7109.00

Temperature range -70~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, using air/water cooling dual-stage Compressor refrigeration system, equipped with multiple safety protection devices and high temperature insulation materials, support environmental testing in line with a number of national standards.

$ 6109.00

Temperature range -80~ 130 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using a unique equilibrate temperature control method to achieve high-precision temperature control, the studio is made of 304 stainless steel.

$ 6575.00

Temperature range -80~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, using a unique equilibrating temperature control method to achieve high-precision stable temperature control to meet a variety of testing needs.

$ 14183.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.
Xenon lamp aging test chamber for testing film weather resistance.
This article introduces how a xenon lamp weathering test chamber tests the weatherability of films. It uses a xenon lamp to simulate sunlight and controls conditions such as temperature and humidity to accelerate the aging process of the film, thereby evaluating its performance changes in outdoor environments.
Evaluation of thermal aging life of hot melt adhesives using high-temperature oven method
This article introduces a method for evaluating the thermal aging life of hot melt adhesives using a high-temperature oven. The principle is based on the Arrhenius equation, where aging is accelerated by increasing the temperature to simulate performance changes under long-term use.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
The impact of temperature, humidity, and vibration coupling in a three-environmental test chamber on the structural fatigue of products.
This article explores the impact of the coupled effects of temperature, humidity, and vibration in a three-comprehensive test chamber on the structural fatigue of products. It explains how such a coupled environment accelerates the degradation of material performance, such as high temperature and humidity reducing the material's fatigue limit, while vibration promotes crack propagation.