Fluorescent Material Color Measurement Device

Fluorescent material colorimeters excite samples with specific light sources and detect their emitted fluorescence spectra and color data. They are used to measure the color characteristics of fluorescent materials, helping to control product color consistency in industries such as coatings and plastics.
Selection
When selecting, consider matching the measurement aperture to the sample size. The instrument must support specialized modes for fluorescent materials, pay attention to repeatability indicators and light source stability, ensure compatibility with existing production processes, and evaluate maintenance costs.

Terms

Instruments

Using LED Illuminant and 45/0 illumination conditions, Measurement range 0~ 199.9, resolution 0.1, can detect Fluorescent Whitening Agent and measure increased whiteness, Repeatability ≤ 0.3.

$ 417.00

Optical inspection system and Modular design, equipped with flat-field color difference elimination fluorescent objective, fretting grid value of 2 μ m, support multi-band fluorescent filter group, comfortable operation.

$ 4688.00

Repeatability of 0.2 for measurement of diffuse reflection factor using 457 nm blue wavelength can detect Fluorescent Whitening Agent and calculate fluorescence whiteness value, which is suitable for surface whiteness analysis of various materials.

$ 554.00

Optical inspection system with infinite distance, equipped with flat-field color difference eliminating fluorescent objective, fretting grid value of 2 μ m, coarse fretting coaxial focusing, support for a variety of fluorescent filter sets, suitable for low-illumination microscopic image shooting.

$ 4398.00

Adopt 45 °/0 ° lighting mode, measurement diaMeter Φ 10mm, Repeatability Standard Deviation is within ≤ E * ab 0.5, support a variety of Color space display and statistical functions, automatic memory 99 sets of data.

$ 282.00

With 45 °/0 ° illumination and D65 Measurement light source, viewing angle of 10 °, support for multiple Color model conversion, weight of only 45g for portability, quality control and complementary color suggestions.

$ 380.00

R457 blue light whiteness formula, Measurement range 0~ 100%, resolution 0.1, Repeatability ≤ 0.3, suitable for fluorescent whitening objects and paper Opacity measurement.

$ 490.00

With high color strength index CRI = 98 and all-metal material, equipped with D65 and D50 dual light sources, it can simulate different lighting conditions, provide uniform lighting and stable structure to ensure accurate and reliable color evaluation.

$ 1848.00

Built-in camera to accurately locate the measurement area, UV Illuminant can measure fluorescent color, Repeatability Delta E * ab ≤ 0.06, supports 26 kinds of Illuminant and 30 + kinds of chroma indicators to meet various measurement needs.

$ 1929.00

With three light sources including D65, TL84 and D50, high color strength index CRI = 98, the all-metal material is stable in structure, providing uniform lighting and accurate color evaluation, suitable for a variety of industry environments.

$ 1961.00

According to the Richter Hardness Measurement principle, it can perform High Accuracy detection on all metal materials, support a variety of Hardness standard conversion, Measurement range HLD 170-960, can store 600 sets of data, equipped with true color screen and USB interface.

$ 296.00

R457 blue light whiteness formula, Measurement range 0~ 199.9%, resolution 0.1, Basis Weight measurement of whiteness of fluorescent whitening objects and paper Opacity, suitable for a variety of materials surface flat samples.

$ 332.00

Built-in camera to accurately locate the measurement area, equipped with UV Illuminant to achieve fluorescent color detection, Repeatability Delta E * ab ≤ 0.06, supports more than 30 chroma indicators and 26 Illuminant conditions, data can be shared through the cloud.

$ 1397.00

Measurement range is 0~ 199.9, Opacity of thin sheet material can be measured, Automatic calibration and Data storage function, Stability and repRoducibility are high, and system drift error is eliminated.

$ 507.00

Special design container to ensure measurement conformity, suitable for color scheme, suitable for fine powder particle measurement, effectively avoid the influence of powder tightness and surface Smoothness.

$ 220.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
A spectrophotometer uses digital language to describe colors, making color differences impossible to hide.
A spectrophotometer measures the color of an object through spectral analysis, converting reflected light data into spectral curves. It then calculates chromaticity parameters such as L*a*b* based on international standards, achieving a digital representation of color.
How to Interpret Color Difference Lab Values Measured by a Spectrophotometer? Save This Color Difference Judgment Standard Now!
This article explains how spectrophotometers measure and evaluate color differences using the Lab color space. In the Lab values, L represents lightness, while a and b indicate the red-green and yellow-blue color biases. The color difference ΔE is calculated using a formula to quantify the variation between a sample and the standard.