Micro-oscillator

The micro-oscillator uses electromagnetic drive to generate high-frequency micro-vibrations in the sample container, ensuring uniform mixing or dissolution of the sample. It is used for pretreatment in the testing of coatings, inks, and other industries to ensure sample representativeness.
Selection
When selecting, consider the sample's viscosity and volume to match the oscillation frequency and amplitude, check the temperature control accuracy to suit the experimental environment, confirm that the clamps are compatible with different container materials, and ensure the operating interface is simple and easy to maintain.

Terms

Standards

Instruments

Using 0.5-2 μL micro-volume sample detection, the optical path accuracy is 0.001mm, the detection concentration is 50 times that of conventional equipment, and the sample recovery and 6-second rapid analysis are supported.

$ 7416.00

Glass sensitive film of 4.5 mm and point ceramic liquid junction, suitable for micro sample measurement, Operating temperature range 0~ 80 ℃, providing stable reference potential.

$ 267.00

Using electromagnetic force equilibrating Sensor technology, dual range design with the highest accuracy of 0.01mg, with micro sample weighing function, Fast Response and Stability, suitable for powder and liquid micro weighing.

$ 1393.00

Oscillation Frequency Range 300-3000rpm, Timed 5-120 minutes, Net weight only 1.2kg, suitable for micro Sample Handling, providing stable oscillation effect.

$ 133.00

Frequency of 710 vibrations per minute, mixing in 30 seconds; can handle 0.5 to 20 liters of barrel paint, equipped with safety interlock and height adjustment functions, quiet operation and easy loading.

$ 1364.00

Elliptical trajectory vertical vibration design, vibration Frequency 660 times/min, maximum load 30KG, equipped with automatic cooling down system to maintain sample temperature stability, closed structure to reduce noise and pollution risk.

$ 14806.00

Equipment Vibration Frequency 660 times/min, maximum load 30KG, elliptical trajectory movement to ensure that the sample test conditions independent equality, equipped with automatic chill down system to maintain temperature stability.

$ 18195.00

Vibration Frequency 660 times/min, maximum load 30KG, elliptical trajectory motion to ensure that the sample test conditions are independent and equal, equipped with automatic chill down system to maintain temperature stability.

$ 16501.00

Micro vibration technology implementation of real-time online measurement, range 0~ 50~ 100mpa.s, accuracy +/- 0.5%, Response Time 2 seconds, suitable for a variety of fluid media.

$ 7335.00

Micro vibration technology implementation viscosity measurement, range 0-5000mpa.s, accuracy +/- 0.5%, Response Time 2 seconds, with IP68 Protection Rating and a variety of connection methods.

$ 7335.00

With 90 ° micro Probe design, Probe measurement port diaMeter is only 5mm, suitable for narrow area measurement; Measurement range 0-625μm, resolution 0.1μm, can obtain more than 60 readings per minute.

$ 1338.00

Speed range 5000 to 35000rpm, output power 120W, support stepless speed regulation, working head with SS316L material, maximum temperature 120 ℃, suitable for micro Sample Handling, with high linear speed and shear force.

$ 1243.00

Micro-gravure plate coating method to achieve ultra-thin uniform coating, Spreader thickness range is wide; integrated online corona treatment makes the substrate surface tension up to 72dyne/cm; drying box temperature control accuracy +/- 3 ℃ to meet different solvent drying needs.

$ 24279.00

Micro vibration technology implementation of real-time online measurement, range coverage of 0-5~ 50-5000pa.s, accuracy of +/- 0.5%, temperature 500 ℃ and Response Time only 2 seconds, suitable for high temperature and high voltage conditions.

$ 7335.00

Using thermal printing technology, it is designed for use with testing instruments. It can directly connect the color difference Meter and Glossmeter to achieve real-time output of measurement data and report generation.

$ 220.00

Articles

Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Weighing lower limit of microbalances and selection basis
The lower weighing limit of a microbalance refers to the minimum mass that can be measured while ensuring accuracy, which is crucial for the reliability of experimental data. It is influenced by factors such as sensor sensitivity, structural resistance to interference, and environmental stability.
Repetibility Test Method and Weights for Semi-micro Balances
This article discusses the method for repeatability testing of semi-micro balances and the use of weights. Repeatability refers to the consistency of the balance's results when weighing the same object multiple times under the same conditions, which is crucial for the reliability of experimental data.
Analysis of Causes for Excessive Repetition Error in Microbalances
Microbalance repeatability out-of-tolerance refers to the situation where the results of multiple weighings of the same object exceed the allowable range of variation.
Determination of free amino acid content in protein solutions using a microtitration apparatus.
This article introduces a method for determining the free amino acid content in protein solutions using a microtiter plate reader. It is based on the ninhydrin color reaction, where amino acids react with the reagent under specific conditions to produce colored compounds, and the concentration is calculated by measuring the absorbance.