Industrial Thermostatic Water Bath

The constant temperature water bath maintains the liquid inside the tank at a stable temperature through heating elements and temperature sensors. It is used for laboratory operations such as constant temperature heating of samples and reaction incubation, and is commonly applied in scenarios like material aging tests and viscosity measurements.
Selection
When selecting, consider the temperature range and accuracy, tank capacity and material, safety protection features, temperature control stability, and power consumption parameters. Match the appropriate specifications and models based on the specific sample dimensions and temperature requirements.

Terms

Standards

Instruments

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

With three uses of water Bath, thermostatic and boiling disinfection, Temperature range RT +~ 100 ℃, Tank volume 36L, suitable for a variety of experimental heating and equipment processing needs.

$ 209.00

Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.

$ 493.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

Adopt stainless steel liner and microcomputer intelligent temperature control instrument, with 0.1 ℃ temperature resolution and +/- 0.5 ℃ Fluctuation, support timing and over-temperature water cut-off alarm function, optional built-in circulating water pump to achieve external circulation thermostatic output.

$ 188.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

Temperature control accuracy of +/- 0.5 ℃, temperature resolution of 0.1 ℃, equipped with built-in circulating water pump can output thermostatic water flow, support timing function to ensure experimental stability.

$ 214.00

Adopt electromagnetic pump circulation mode, Temperature range 5~ 80 ℃, Temperature Fluctuation +/- 0.2 ℃, equipped with water shortage protection function to prevent accidents, support a variety of interface connections.

$ 433.00

304 stainless steel one-time stretch forming liner, no water leakage; four-corner arc design to ensure temperature uniformity; temperature control accuracy of +/- 0.5 ℃, heating power 600W, to meet the long-term stable thermostatic needs.

$ 160.00

Using Stainless Steel liner and High Sensitive Platinum Resistance Sensor, Temperature range RT-100 ℃, temperature control is accurate, suitable for precision thermostatic experimental needs.

$ 225.00

Water Bath, water temperature box and boiling disinfection box three functions, Temperature range from room temperature to 100 ℃, Tank size 42 * 18 * 20cm, to meet a variety of experimental heating and disinfection needs.

$ 180.00

Stainless steel liner, beaker hole can be arbitrarily changed size; High Accuracy Microcomputer temperature control, Temperature range RT + 5~ 100 ℃, thermostatic Fluctuation +/- 0.5 ℃, over temperature sound and light tracking alarm to protect the sample.

$ 177.00

Articles

Application of Drop Hammer Impact Testing Machine in Evaluating Impact Resistance of Composite Materials
This article introduces how the drop-weight impact testing machine evaluates the impact resistance of composite materials. The test releases a weight to strike the specimen, measuring parameters such as energy absorption, peak load, and damage area, simulating low-velocity impacts like tool drops.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
Application of High-Frequency Fatigue Testing Machine in Infinite Life Testing of Valve Springs
This article discusses the application of high-frequency fatigue testing machines in the infinite life testing of valve springs. The test simulates the long-term working stress of the spring through high-frequency cyclic loading, with parameters such as preload, amplitude, and cycle count set according to international standards.
Selection of Clean Bench: Methods for Determining Airflow Direction and Cleanliness Class
This article primarily discusses the selection methods for clean benches, focusing on two aspects: first, determining the airflow direction based on experimental requirements—vertical laminar flow is suitable for protecting the operator, while horizontal laminar flow is ideal for protecting samples; second, selecting the cleanliness level according to ISO standards, typically requiring ISO Class 5.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Optimization of mixing efficiency of vortex mixer in liquid-liquid microextraction
This paper explores how to enhance mixing efficiency in liquid-liquid microextraction by adjusting the operating parameters of a vortex mixer.
Gelation Time Tester in the Testing of Thermosetting Resin Curing Process
The gel time tester is used to measure the transition time of thermosetting resins from a liquid state to a gel state, which is crucial for controlling the curing process and product quality.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Study on the Dispersion Uniformity of Blade Coating Machines in High-Load Electrode Slurry Coating
This article investigates how to optimize the dispersion uniformity of coatings by adjusting process parameters when using a blade coater to handle high-load electrode slurries.
Capacity Matching for Laboratory Small Dispersers and Pilot Dispersers
This article primarily discusses how to select the appropriate disperser for laboratory research and process development.
Research on the Stepwise Curing Process of Coatings Using Multi-Stage Temperature Control Ovens
This article investigates a novel process for achieving stepwise curing of coatings using a multi-stage temperature-controlled oven.