Digital Blast Constant Temperature Drying Oven

The digital display forced air constant temperature drying oven heats via electric heating tubes, circulates hot air with a fan, and maintains a constant temperature inside the chamber through a digital temperature controller. It is used to remove moisture from samples and cure materials, commonly applied in scenarios such as laboratory drying and material heat treatment.
Selection
When selecting, consider the chamber size to match the sample volume, ensure the temperature range covers experimental needs, and verify the temperature control accuracy meets process standards. Pay attention to the fan type to ensure uniform heating, check that the material's corrosion resistance suits the usage environment, and ensure safety devices are fully equipped.

Terms

Standards

Instruments

Using microcomputer intelligent PID digital display temperature control, temperature control accuracy +/- 1 ℃, equipped with hot air circulation system to ensure uniform temperature, indoor shelf height and quantity adjustable, easy access to different specifications of samples.

$ 288.00

Microcomputer intelligent PID digital display temperature control, temperature Accuracy +/- 1 ℃, equipped with hot air circulation system and double-decked tempered Glass observation window, studio shelf height can be adjusted, support independent temperature control function.

$ 327.00

Adopt microcomputer intelligent PID digital display thermostat, Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 1%. The hot air circulation system consists of low-noise fans and air ducts, and the height and number of studio shelves can be adjusted to facilitate access to samples of different specifications.

$ 343.00

Adopt microcomputer intelligent PID digital display thermostat, Temperature range RT + 5~ 300 ℃, Temperature Accuracy +/- 1 ℃. The hot air circulation system consists of low-noise fans and air ducts, and the height and number of shelves in the studio can be adjusted, which is convenient for accessing samples of different specifications.

$ 554.00

Using digital microcomputer thermostat accuracy of 0.1 ℃, equipped with hot air circulation system to make Temperature Uniformity +/- 2.0 ℃, with timing and temperature control protection function, mirror stainless steel liner durable and easy to clean.

$ 649.00

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, equipped with intelligent digital display and observation window, uniform and stable heating, suitable for a variety of material drying needs.

$ 356.00

Using digital microcomputer temperature controller accuracy of 0.1 ℃, equipped with double-decked tempered Glass observation window and hot air circulation system, to ensure that the indoor Temperature Uniformity +/- 2.0 ℃, with timing function and independent temperature limit alarm system.

$ 451.00

Digital display microcomputer temperature controller accuracy of 0.1 ℃, vertical forced convection design to ensure the studio Temperature Uniformity +/- 2.0 ℃, equipped with double-decked tempered Glass observation window and independent temperature limit alarm system, support timing function and fan control.

$ 672.00

Using microcomputer intelligent PID digital display thermostat, Temperature range RT + 5~ 300 ℃, Temperature Fluctuation +/- 2%. The hot air circulation system consists of low-noise fans and air ducts, and the height and number of shelves in the studio can be adjusted, which is convenient for accessing samples of different specifications.

$ 425.00

Adopt digital display microcomputer temperature controller, accuracy up to 0.1 ℃, with timing and temperature control protection function. Vertical forced convection design ensures uniform temperature in the working room, Temperature Uniformity +/- 2.0 ℃.

$ 528.00

Adopt digital display microcomputer temperature controller, accuracy of 0.1 ℃, Temperature Uniformity +/- 2.0 ℃. Vertical forced convection design ensures uniform temperature, double-decked tempered Glass observation window and independent temperature limit alarm system to ensure experimental safety.

$ 793.00

Adopt microcomputer intelligent PID digital display thermostat, temperature control accuracy +/- 1 ℃, Temperature Fluctuation +/- 2%. The hot air circulation system consists of low-noise fans and air ducts, the number of studio shelves can be adjusted, and the double-decked tempered Glass observation window is easy to observe.

$ 1064.00

Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 1 ℃, equipped with stainless steel liner and intelligent digital display to ensure Temperature uniformity and durability.

$ 356.00

Using microcomputer P.I.D temperature controller, temperature control accuracy +/- 1.0 ℃, Temperature Uniformity +/- 3%, hot air circulation system to improve Temperature uniformity, independent temperature limit alarm system to ensure safe operation of the experiment.

$ 606.00

Microcomputer intelligent PID control technology to ensure temperature Accuracy +/- 0.5 ℃, the external hot air circulation system makes the indoor temperature stable, high temperature silicone sealing door edge and high temperature heating tube to ensure safety and durability.

$ 323.00