Dual Mixers

The dual mixer utilizes two independently rotating stirrers to create mixing actions with different flow directions within the container, enabling rapid and uniform dispersion of materials. It is used for sample preparation and performance testing in industries such as coatings and inks, ensuring batch consistency.
Selection
When selecting, consider matching the material viscosity with the speed range, using stainless steel for corrosion resistance, ensuring the heating function accommodates temperature-sensitive materials, determining the capacity based on sample volume, and ensuring the fixation method guarantees operational stability.

Terms

Standards

Instruments

With dual range 1.5kg + 3kg and dual accuracy 0.01g + 0.02g, it supports dual mode conversion of weight counting, built-in temperature display and adjustable six-level shock-proof filter to ensure stable and reliable weighing.

$ 325.00

With dual range and dual accuracy design, Capacity 30kg + 40kg, minimum weighing 0.1g + 0.5g, support dual mode of weight counting, six-stage shock-proof filtering and various unit conversions to meet the needs of complex industrial environments.

$ 532.00

With dual range and dual accuracy function, Capacity 6kg + 20kg, Minimum Weight 0.1g + 0.5g, support twenty unit conversions and a variety of weighing application modes.

$ 273.00

It has 15kg + 30kg dual range and 0.1g + 0.2g dual accuracy, supports dual mode switching of weight counting, built-in six-level shock-proof filtering and temperature display functions, and provides twenty unit conversions and a variety of weighing application modes.

$ 325.00

With 15kg + 30kg dual range and 0.5g + 0.5g dual accuracy, support dual mode conversion of weight counting, built-in six-level shock-proof filtering and temperature display functions, provide twenty unit conversions and a variety of professional weighing modes.

$ 273.00

It has 30kg + 15kg dual range and 0.5g + 0.2g dual accuracy, supports dual mode of weight counting, built-in six-level shock-proof filtering and temperature display functions, and provides twenty unit conversions and a variety of weighing application modes.

$ 286.00

With dual range double accuracy function, weighing range 50kg + 10kg, accuracy 0.5g + 0.1g, support weighing and counting dual mode, Automatic calibration and a variety of unit conversion, the structure is sturdy and durable.

$ 306.00

Single Sensor technology implementation is compatible with Fast Response and Stability, with 1/2mg Readability and Dual Range function, supports six filter adjustment and twenty weighing Unit switches.

$ 1655.00

With dual range and double accuracy design, weighing range up to 20kg + 30kg, accuracy 0.1g + 0.2g, support six-level shock filtering and a variety of weighing modes, adapt to complex industrial environment.

$ 396.00

The dual-channel interface can connect two Probes at the same time, support K-type -200~ 999.9 ℃ wide range, with low power error-proof system and data locking function, waterproof design to adapt to a variety of environments.

$ 604.00

Single Precision Sensor for Fast Response and Durability, with 0.01g/0.02g Readability and Automatic Dual Range function, supports six-level filter adjustable and multiple weighing modes to ensure high conformity and sensitive and stable compatibility.

$ 1542.00

With dual range double accuracy function, Capacity 7kg, accuracy up to 0.01g, support six-level shock filter and twenty unit conversion, built-in temperature display and a variety of weighing modes to meet the needs of accurate weighing in complex environments.

$ 448.00

Single Sensor technology implementation Fast Response and stability compatible, with 0.1mg/0.5mg Readability and automatic dual range function, support six filter adjustable and a variety of weighing modes.

$ 1982.00

With dual-mode measurement of conductivity and induction, nondestructive detection; Measurement range 0~ 80%, accuracy +/- (0.5% n + 1); Support USB, RS-232 and Bluetooth output, provide digital and LED status dual display.

$ 243.00

Dual channel design can simultaneously measure two samples, temperature range -50 ℃ to 1350 ℃, equipped with waterproof structure and dual LCD display, support data locking function, easy and reliable operation.

$ 354.00

Articles

Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Cupping test instrument detects the cracking resistance of coatings under deformation.
This article introduces how the cupping test instrument detects the cracking resistance of coatings under deformation. It uses a spherical punch to uniformly press against the back of the sample, causing the coating to bulge with the substrate, simulating biaxial stretching until the coating cracks. The indentation depth at this point is recorded as the key indicator.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Application of Two-Step Method with Pre-Coating and Fine-Coating in Eliminating Bubble Defects for Dual-Blade Coater
The dual-blade coater employs a two-step method of pre-coating and precision coating to eliminate bubble defects during the coating process. In the pre-coating stage, high shear force is applied to break the bubbles in the slurry, causing them to rupture and rise to the surface. The precision coating stage then precisely controls the coating thickness, removing any remaining bubbles to form a uniform wet film.
Differences between single-beam and double-beam structures in paper stiffness testers
Paper stiffness testers come in both single-beam and double-beam structures. The choice should be based on testing standards, sample thickness, and precision requirements.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Cupping tester evaluates the ductility of coatings.
The cupping tester is a detection device used to evaluate the ductility of coatings under biaxial tension. During the test, the punch presses the sample into the die until the first continuous crack appears in the coating, at which point the penetration depth of the punch is recorded as the cupping depth.
How does a roll-to-roll coating machine achieve double-sided coating?
How does a roll-to-roll coating machine achieve double-sided coating? Double-sided coating is a process that simultaneously or sequentially applies functional coatings to both sides of a flexible substrate (such as film, paper, or metal foil).
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Pendulum Hardness Determination: Comparison of Applicability between Double Pendulum Method and Compound Pendulum Method
This article compares two pendulum methods for measuring coating hardness. The choice of method should consider material hardness and testing conditions, and both methods require standardized calibration and sample preparation.
When selecting a drop testing machine, whether to choose a single-arm or double-arm configuration depends on the size and weight of the packaging.
When selecting a drop tester, the choice between a single-arm or double-arm model mainly depends on the size and weight of the packaging. For small, lightweight, and regularly shaped items, a single-arm tester is sufficient. However, for larger, heavier, or irregularly shaped items, it is better to choose a double-arm tester, as it offers greater stability and ensures more accurate test results.