Thermostatic Temperature Measurement Bath

The thermostatic water bath heats the liquid medium through electric heating tubes and maintains a constant temperature using a temperature controller, providing a stable thermal field for samples. It is used in laboratory applications such as constant-temperature heating of samples, reaction insulation, and viscosity testing.
Selection
When selecting, pay attention to the temperature range and accuracy to match experimental needs, ensure the tank size accommodates the sample capacity, consider the material's corrosion resistance, confirm that safety protection functions are complete, and balance heating speed with temperature uniformity.

Terms

Instruments

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

The 24-hole design is compatible with the testtube with a diaMeter of less than 12mm, the maximum Operating temperature is 100 ° C, and the electronic ice box and intelligent thermostatic metal Bath module are optional to meet different temperature requirements.

$ 148.00

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

With three uses of water Bath, thermostatic and boiling disinfection, Temperature range RT +~ 100 ℃, Tank volume 36L, suitable for a variety of experimental heating and equipment processing needs.

$ 209.00

Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.

$ 493.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

It adopts transparent carbonic acid ester Bath design, with a volume of 6L, equipped with pressure/suction pump and Pt100 temperature sensor, with low liquid level protection and hardware over-temperature protection functions, and supports external circulation temperature control.

$ 1519.00

Using transparent carbonic acid ester Bath design, the highest Operating temperature is 100 ℃, equipped with pressure/suction pump to provide 22L/min Flow rate, support external circulation and Pt100 temperature sensor precise temperature control.

$ 841.00

Support 100 ℃ high temperature heating, suitable for 24 holes 5ml centrifuge tube, optional electronic ice box and thermostatic metal Bath module, achieve precise temperature control and diverse Sample Handling.

$ 175.00

Using transparent carbonic acid ester Bath design, the highest Operating temperature of 100 ℃, equipped with pressure suction pump to provide 12L/min Flow rate, support multi-stage program control and external temperature sensor precise temperature control, with liquid level and hardware overtemperature double protection function.

$ 1632.00

Using transparent carbonic acid ester Bath design, the highest Operating temperature of 100 ℃, equipped with 20L volume Tank body; with low liquid level protection and hardware over-temperature protection function, in line with DIN12876 standard III Safety level, support external circulation and precise temperature control.

$ 1858.00

Temperature control accuracy of +/- 0.5 ℃, temperature resolution of 0.1 ℃, equipped with built-in circulating water pump can output thermostatic water flow, support timing function to ensure experimental stability.

$ 214.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Considerations for Channel Count and Temperature Endurance in Furnace Temperature Tracker Selection
When selecting a furnace temperature tracker, the main considerations are the number of channels and the temperature resistance duration. The number of channels is determined based on the quantity of temperature measurement points plus spare channels. Too few channels may lead to data loss, while too many channels can increase costs.
Temperature Paper Selection: Temperature Gradation and Response Speed Evaluation
This article mainly discusses how to choose the right temperature measurement paper. It points out that two key parameters should be considered during selection: the temperature steps and the response speed.
Constant Temperature Water Bath Controls the Temperature Sensitivity of Resin Viscosity
The constant temperature water bath can provide a stable temperature environment for studying the characteristics of resin viscosity as it changes with temperature.