Thermostatic Bath with Oil Tank

The constant temperature oil bath uses a heater and temperature sensor to form a closed-loop control system, circulating heat transfer oil within a sealed tank to maintain the set temperature. It is used for calibrating temperature instruments, testing thermal deformation of materials, and insulating reaction vessels, with a typical operating range from room temperature to 300℃.
Selection
When selecting, consider the temperature range and fluctuation indicators, and determine the flash point of the oil based on the experimental medium. The tank size must match the sample volume, paying attention to the observation window and port configuration. Focus on safety protection and energy consumption data, and regularly replace the thermal oil to maintain thermal stability.

Terms

Standards

Instruments

With three uses of water Bath, thermostatic and boiling disinfection, Temperature range RT +~ 100 ℃, Tank volume 36L, suitable for a variety of experimental heating and equipment processing needs.

$ 209.00

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, Temperature control accuracy 0.01 ℃, Built-in High Accuracy PT100 Sensor, support external circulation and domestic circulation system, ensure that the flow field and temperature field in the Tank are highly uniform.

$ 869.00

Temperature range up to 300 ℃, Tank volume 36L, using domestic circulation design to ensure temperature uniformity, suitable for a variety of experimental operations.

$ 548.00

Temperature range RT +~ 300 ℃, Tank volume 23L, suitable for distillation, drying, condensing and impregnation and other experimental operations, to meet a variety of chemical and biological experimental needs.

$ 451.00

With water and oil dual-use function, temperature control accuracy of 0.01 ℃, Temperature Uniformity +/- 0.05 ℃, built-in High Accuracy PT100 Sensor, support for external circulation to establish a second thermostatic field, equipped with multiple Safety protection devices.

$ 677.00

With water-oil dual-use function, Temperature Uniformity +/- 0.05 ℃, built-in High Accuracy PT100 Sensor, support for external circulation to establish a second thermostatic field, optional program temperature control and Communication interface.

$ 1048.00

With the function of water-oil dual-use, Temperature Uniformity up to +/- 0.05 ℃, no heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field and support the establishment of a second thermostatic field for external circulation.

$ 564.00

With water and oil dual-use function, Temperature Uniformity +/- 0.05 ℃, Temperature range from room temperature to 200 ℃, domestic circulation system adopts no heat centrifugal pump to avoid affecting the temperature field, support external circulation to establish a second thermostatic field.

$ 924.00

Water Bath, water temperature box and boiling disinfection box three functions, Temperature range from room temperature to 100 ℃, Tank size 42 * 18 * 20cm, to meet a variety of experimental heating and disinfection needs.

$ 180.00

Water and oil dual-use optional room temperature to 100 ℃ range, external circulation function to establish a second thermostatic field, Temperature Uniformity +/- 0.05 ℃, domestic circulation without heat centrifugal pump to avoid the impact of temperature field, Safety protection including power failure and low water level alarm.

$ 1058.00

Temperature range RT + 5~ 200 ℃, temperature fluctuation +/- 0.5 ℃, built-in circulating water pump can output thermostatic water flow, microcomputer intelligent temperature controller with timing and over-temperature alarm function.

$ 532.00

Water and oil dual-use supports room temperature to 100 ° C, capacity 5L, Temperature Uniformity +/- 0.05 ° C, with domestic circulation system to avoid heat effects, external circulation to establish a second thermostatic field, Safety protection includes power failure and low water level alarm.

$ 435.00

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, no heat centrifugal circulation pump to avoid its own heat generation affecting the temperature field, support external circulation to establish a second thermostatic field, built-in multiple Safety protection devices.

$ 798.00

With water-oil dual-use function, Temperature Uniformity up to +/- 0.05 ℃, temperature control accuracy 0.01 ℃; no heat centrifugal circulation pump to avoid self-heating effect, porous U-shaped return design to achieve uniform turbulence; Equipped with multiple Safety protection and external circulation to establish a second thermostatic field.

$ 617.00

With water and oil dual-use function, temperature control accuracy of 0.01 ℃, Temperature Uniformity +/- 0.05 ℃, domestic circulation system adopts no heat centrifugal pump to avoid its own heat generation affecting the uniformity of temperature field, support external circulation to establish a second thermostatic field.

$ 959.00