Single salt bridge structure and bulb sensitive membrane are adopted. Measurement range is 0-14pH and temperature adaptability is 0-100 ℃.
Glass material, Measurement range 0-13 pH, Temperature resistance 0-100 ℃, Single ceramic dialysis hole design to improve Stability, suitable for high temperature and high voltage environment.
Glass shell and sensitive membrane, pH Measurement range 0-14pH, Temperature range 5-60 ℃, suitable for routine sample measurement, liquid boundary is ceramic core single salt bridge, reference type Ag/AgCl.
Suitable for 0~ 80 ℃ high temperature environment, Measurement accuracy of 0.01pH, Sensitivity high, more than 60 ℃ can still work stably, with Calomel electRode through potential changes reflect the pH value of the solution.
Equipped with planar pH ElectRode, Measurement accuracy is 0.05pH, support 2 point calibrating and automatic temperature compensation, fully waterproof design and replaceable ElectRode, prolong service life.
Measurement range 0-14pH, Temperature range 5-60 ℃, polyformaldehyde single salt bridge design, suitable for high pollution samples, Glass bulb sensitive film to ensure stable Response.
Using external ElectRode design, Measurement accuracy of 0.01pH, support 0.1-14 pH range and 0-50 ℃ temperature measurement, small size for on-site detection and operation.
Fast Response with Planar pH ElectRode, Automatic temperature compensation and 1-3 point Adjustment, Measurement accuracy of 0.01 pH, Support automatic end point locking and full waterproof design.
Glass electRode design, rugged, in line with IP67 waterproof standards; Measurement range - 2.00~ 16.00pH, accuracy +/- 0.02pH; built-in automatic temperature compensation and Sensor Check ™ function, convenient real-time monitoring of ElectRode status.
Using planar pH ElectRode design, Measurement accuracy of 0.01pH, Support 1-3 point Automatic calibration, with automatic temperature compensation and end point locking function, full waterproof structure to ensure harsh environment use.
Adopt three-in-one composite structure, equipped with PT-100 temperature sensor and fiber single salt bridge, Measurement range 0-14pH, Temperature range 5-60 ℃, shell made of polycarbonic acid ester material, connector compatible with BNC interface.
Measurement accuracy of 0.01 pH, support for automatic temperature compensation and 1 to 3 point calibrating, fully waterproof design for harsh environments, can replace ElectRode to reduce maintenance costs.
Using Titanium Body ElectRode and Flat Glass Design, Measurement range 0.00~ 12.00pH, accuracy +/- 0.05pH, Automatic calibration and 1000 hours battery life, suitable for harsh environments.
Measurement range 0-14pH, Temperature range 5-60 ℃, Liquid junction of fiber single salt bridge, shell made of polycarbonic acid ester and sensitive film Glass bulb.
Instrument and ElectRode separation design, equipped with E201-C composite ElectRode, Measurement accuracy +/- 0.1pH, small shape only 120 * 40 * 34mm, easy to carry and easy to replace ElectRode.