Four-Sided Paint Coating Applicator

The four-sided coating applicator uses four adjustable blades to form wet films of different thicknesses on a substrate, simulating the actual coating process. Its purpose is to quickly test the leveling, hiding power, and color uniformity of coatings, and it is applied in laboratory formulation development and quality control.
Selection
When selecting, consider the substrate type to match the coating width, determine the blade gap range based on the coating viscosity, require stainless steel material for corrosion resistance, include a thickness calibration certificate to ensure accuracy, and ensure the operation interface is clear and easy to read.

Terms

Standards

Instruments

The four-sided design allows for the preparation of film thicknesses of 200μm, 400μm, 600μm, and 800μm. Made of stainless steel, it offers high coating precision, a compact size, and is suitable for various substrates and coatings with different pH levels.

$ 275.00

The 4-sided coating Applicator can be prepative of four wet film thicknesses, the accuracy is +/- 3μm, the application width is 80mm, the stainless steel material is resistant to corrosion, and the operation is simple only need to change the angle.

$ 1172.00

The 4-sided coating Applicator can be prepative of four wet film thicknesses, the conversion angle is easy to operate, the accuracy is +/- 3μm, the stainless steel material is resistant to acid and alkali erosion, and the application width is 80mm.

$ 1235.00

The 4-sided paint design can be prepared with four different thickness wet-film, application width 75mm, accuracy +/- 3μm, corrosion-resistant stainless steel material, easy to clean and durable.

$ 1268.00

The integrated design can convert four film thicknesses, the accuracy is +/- 3μm, the stainless steel material is resistant to corrosion, and the conductive film can be removed for easy cleaning and maintenance.

$ 1117.00

The 4-sided design can convert the angle to obtain four wet film thicknesses, the accuracy is +/- 3μm, the stainless steel material is resistant to acid and alkali corrosion, and the conductive smear is removable for easy cleaning and maintenance.

$ 1172.00

The 4-sided design can be prepared with four wet film thicknesses, and the conversion angle is easy to operate; the stainless steel material is resistant to acid and alkali corrosion, and the conductive film can be disassembled; the application width is 60mm, and the accuracy is +/- 3μm to ensure the accuracy of the test.

$ 1046.00

The 4-sided design can convert the angle to obtain four wet film thicknesses, the application width is 60mm, the accuracy is +/- 3μm, the stainless steel material is resistant to acid and alkali corrosion, and the guide film can be removed for easy operation and maintenance.

$ 1117.00

The 4-sided design can be coated with four preset thicknesses, the application width is 80mm, the accuracy is +/- 3μm, and the stainless steel material is resistant to acid and alkali corrosion, which meets the requirements of ASTM standards.

$ 1006.00

The 4-sided design can be prepared with four film thicknesses, high film accuracy, small size and easy operation, stainless steel material is used to ensure durability, and the application width 80mm is suitable for a variety of substrate surfaces.

$ 146.00

The 4-sided structure can prepare 12 kinds of film thickness, the wet film thickness range is 30-100μm, the accuracy is +/- 2μm, the application width is not less than 60mm, and the coating does not spill during the Moulding process.

$ 164.00

The device can be prepared with 12 wet film thicknesses, ranging from 30-600μm, accuracy up to +/- 002-0.012 mm, 4-sided design to ensure that the coating does not spill, suitable for a variety of substrate surface Spreaders.

$ 164.00

4-Sided cylindrical design Spreader four different thicknesses, application width 80mm, accuracy of +/- 3μm, stainless steel material acid and alkali corrosion resistance.

$ 1344.00

The 4-sided design can be used for four film thicknesses, high film accuracy and small size, application width 80mm, suitable for a variety of substrates and pRoducts with different chemical properties.

$ 146.00

Hard stainless steel material acid and alkali erosion, can be prepared 100/150/200/250μm four thickness wet-film, the operation of the conversion angle can switch the thickness, application width 80mm.

$ 186.00

Articles

Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Application of Xenon Lamp Aging Test Chamber in Automotive Coatings ASTM G155
Xenon lamp aging test chambers simulate environmental conditions such as solar radiation, temperature, and humidity to evaluate the weather resistance of automotive coatings under the ASTM G155 standard.
Safety Considerations for Selecting Explosion-Proof vs. Ordinary Drying Ovens in Paint Laboratories
When selecting a drying oven in a paint laboratory, the type should be determined based on the safety risks of the samples and the environment.
Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Selection of laboratory grinders is based on the fineness requirements of coatings, choosing between ball mills or sand mills.
The selection of a laboratory grinder should be based on the fineness requirements of the coating. A fineness greater than 50 microns indicates coarse dispersion, 10 to 50 microns is considered medium fineness, and less than 10 microns requires high fineness dispersion.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Technical Details of Measuring Paint Contrast Ratio Using Black-and-White Checkerboard Method with Hiding Power Card
This article introduces a method for measuring the hiding power of coatings using black and white checkerboard paper.
Wear testing machine evaluates the wear resistance performance of wood and floor coatings.
This article introduces how to use a wear testing machine to evaluate the wear resistance of wood and floor coatings.