Halogen Fast Moisture Analyzer

The halogen moisture analyzer heats the sample using a halogen lamp, rapidly evaporates moisture through infrared radiation, and monitors mass changes in real-time with a weighing system to calculate moisture content. It is used for on-site moisture detection of materials such as coatings and plastics, offering simple operation and quick results.
Selection
When selecting, focus on whether the heating temperature range matches the sample characteristics, whether the weighing accuracy meets testing requirements, and whether it has calibration functions. Consider the corrosion resistance of the sample tray material, whether the instrument size fits the workspace, and whether the operation interface is clear and user-friendly.

Terms

Standards

Instruments

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Using pyrolysis weight principle design, moisture readability of 0.01%, Heating Temperature range RT +~ 180 ℃, equipped with halogen heating unit and 5 inch Touchscreen, can automatically measure a variety of moisture paraMeters.

$ 399.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Using annular halogen lamp heating, heating fast and uniform, Heating Temperature range RT + 40~ 199 ℃, moisture accuracy of 0.1%, with imported Sensor to ensure stable weighing, support data storage and printing.

$ 814.00

The annular halogen lamp is used to heat the sample evenly and quickly, and the surface is not easily damaged. Capacity 100g, moisture measurement range 0.00~ 100%, and the general sample can be measured in a few minutes.

$ 388.00

Using annular halogen lamp heating, the sample is uniform and fast drying, the surface is not easy to damage, Capacity 100g, Heating Temperature range RT +~ 160 ℃, the general sample can be measured in a few minutes.

$ 319.00

The annular halogen lamp is uniformly heated, Capacity 50g, moisture measurement range 0.00-100%, heating temperature can reach 160 ℃, the general sample can be measured in just a few minutes, and the detection efficiency is high.

$ 388.00

Using annular halogen lamp heating, Temperature range RT +~ 180 ℃, the fastest few minutes to complete the measurement; Equipped with Draft Shield and imported Sensor, the heating performance is uniform and stable, supporting the simultaneous conversion of water content and solid content.

$ 441.00

Using pyrolysis weighting principle, equipped with halogen heating unit, moisture readability of 0.01%, weighing range 0.001-120g, with automatic manual timing three Test methods, support Data storage and Communication interface.

$ 420.00

It adopts annular halogen lamp heating and multi-layer stainless steel heating Chamber, heating up fast and uniform, moisture measurement accuracy of 0.1%, equipped with German imported Sensor to ensure stable weighing, support data storage and printing functions.

$ 1124.00

Ring halogen lamp heating to ensure uniform and fast drying of samples, Capacity 50g, Measurement accuracy 0.01%, support 0~ 99 minutes timing, 9 kinds of paraMeter display, suitable for solid, particle and other Sample types.

$ 344.00

Moisture is measured by thermogravimetry, equipped with 500W high-efficiency halogen ring lamp for uniform heating, Temperature range 40-180 ℃ controllable. 5-inch Touchscreen real-time display of moisture change Linear dispersion, support automatic shutdown and Data storage 100 groups, intuitive operation without supervision.

$ 420.00

The annular halogen lamp is used for direct internal heating to shorten the drying time; the single electromagnetic force Sensor ensures 0.1mg weighing readability, heating Temperature range 60~ 200 ℃, and supports a variety of end modes.

$ 1124.00

Using thermogravimetry principle, moisture readability of 0.01%, equipped with 500W high efficiency halogen lamp and PT100 temperature sensor, heating Temperature range 40-180 ℃, support automatic shutdown and real-time Linear dispersion display.

$ 378.00

Using halogen lamp heating technology, Capacity 110g, readability 0.001g, heating temperature up to 200 ° C, fast drying and real-time display of moisture percentage, suitable for a variety of sample analysis.

$ 566.00

Articles

Comparison Between Halogen Moisture Analyzer and Karl Fischer Moisture Analyzer in Plastic Moisture Detection
This article compares the differences between halogen moisture analyzers and Karl Fischer moisture analyzers in detecting moisture in plastics.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
Halogen Moisture Analyzer for Rapid Determination of Solid Content in Water-Based Coatings
This article introduces a method for rapidly measuring the solid content of water-based coatings using a halogen moisture analyzer.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.