Scale RefractoMeter

The scale refractometer determines concentration by measuring the refractive index of a liquid. When light passes through the prism and the sample, it refracts, and the light-dark boundary line in the eyepiece corresponds to the scale, allowing for direct reading of the value. It is used to detect the concentration of solutions such as sugar solutions and electrolytes, enabling rapid on-site measurements in the food and chemical industries.
Selection
When selecting, consider whether the measurement range and accuracy meet the sample concentration requirements. Observe the clarity of the eyepiece and the legibility of the scale, and check the wear resistance of the prism and the temperature compensation function. Portable models are suitable for fieldwork, while benchtop models are suitable for laboratory environments. Calibration requires the use of standard solutions to verify accuracy.

Terms

Instruments

Measurement range 0~ 60% Brix, minimum reading 0.005, scale reading mode, small shape only 155mm, light weight 160g, easy to quickly detect on site.

$ 122.00

Measurement range 28~ 62% Brix, minimum reading 0.002, scale reading mode, small shape only 155mm, Net weight 160g, easy to quickly detect on site.

$ 122.00

Optical inspection principle measurement of liquid concentration, Measurement range 0~ 32% Brix, minimum reading 0.002, compact shape only 155mm, light weight to 160g, easy to quickly detect on site.

$ 122.00

Measurement range 0~ 5% Brix, minimum reading 0.10% Brix, scale reading mode, compact and portable, weighing only 160g, suitable for fast on-site inspection.

$ 122.00

Maximum range 500g, accuracy 20mg, metal beam thickened design, scale engraving is clear and not easy to abrasion, and the bottom is equipped with horizontal adjustment screws to ensure stability.

$ 127.00

Adopt scale differential head adjustment, Graduation 10μm, film thickness 0~ 5000μm adjustable, accuracy +/- 2μm, Drawdown blade straightness +/- 2μm, die steel material wear and corrosion resistance.

$ 519.00

Measurement range 0~ 50% Brix, minimum reading 0.005, scale reading mode, compact shape only 155mm × 25mm × 40mm, Net weight 160g easy to carry.

$ 122.00

With 0~ 20% Brix Measurement range and 0.001 minimum reading, using scale reading mode, the small shape is only 155mm, which is convenient for quick detection of liquid concentration on site.

$ 122.00

Adopt scale differential head adjustment, Graduation 10μm, Drawdown blade straightness +/- 2μm, with 0~ 5000 micron large range adjustable and die steel Drawdown blade high wear resistance and corrosion resistance.

$ 735.00

Measurement range 0~ 18% Brix, minimum reading 0.001, scale reading mode, Dimension 155 * 25 * 40mm, Net weight 160g, easy to carry and fast detection.

$ 122.00

Measurement range 0~ 90%, minimum reading 0.005, using scale reading mode, small shape only 155mm, light weight to 160g, suitable for on-site rapid detection.

$ 122.00

Adopt scale differential head adjustment, Graduation 10μm, film range 0~ 5000μm, accuracy +/- 5μm, Drawdown blade straightness +/- 2μm, die steel material to ensure high wear resistance and corrosion resistance.

$ 896.00

Measurement range 0~ 80% sugar content, minimum reading 0.005, using scale reading mode, small shape only 155mm, light weight 160g, suitable for on-site rapid detection.

$ 122.00

Three concentration units of honey can be measured, Brix range 58~ 92%, Be 'range 38~ 43 °, Water range 12~ 27%, scale reading method, small size only 155mm, light weight 160g.

$ 122.00

In line with the LOVIBOND color scale standard, the sub-field of view Color matching Sensitivity is high, the Measurement range is red 0.1-79, yellow 0.1-79 LOVIBOND units, and the structure is simple and easy to operate.

$ 599.00

Articles

Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Wet film thickness gauge measures the wet film thickness of varnish.
The wet film thickness gauge is a mechanical tool used to measure the thickness of liquid varnish coatings. It operates by rolling the gauge so that the tips of its teeth contact the substrate and leave marks. The thickness value is then obtained by the operator reading the scale of the first tooth that becomes coated with the varnish.
Operating Specifications and Result Interpretation of Paint Fineness Gauges
The fineness gauge is used to measure the dispersion of particles in paint. During operation, the sample should be applied to the groove under standard conditions, and a scraper is used to spread it evenly to form a wet film. The particle visibility is then observed under appropriate lighting, and the fineness value is read from the corresponding scale.
The correct method for using a wet film thickness gauge.
The wet film thickness gauge is used to measure the thickness of uncured coatings. It determines the value by reading the scale through contact with the wet film using a toothed structure, which is crucial for controlling dry film thickness and estimating material usage.
Scraper Fineness Gauge for Determining the Fineness of Paste Inks
The Scraper Fineness Gauge is used to measure the dispersion degree of pigment particles in products such as paste inks. Its principle involves scraping a film on a scraper plate with wedge-shaped grooves and observing the scale at which particles appear to assess the fineness, with the result expressed in micrometers.