Color Difference & Gloss Meter

The color difference gloss meter calculates color difference values and gloss levels by measuring the intensity of reflected light and color data from an object's surface. It is used in industries such as coatings and plastics for controlling product color consistency and evaluating surface gloss, ensuring stable appearance quality across production batches.
Selection
When selecting, consider matching the measurement aperture to the sample size, choose gloss measurement angles of 20°/60°/85° as per standards, check the instrument's repeatability metrics, ensure compliance with industry standards such as ASTM D523, and verify compatibility with existing color management systems.

Terms

Standards

Instruments

With Φ 4mm and Φ 8mm dual measurement caliber, Repeatability Delta E * ab < 0.06, can store 100 sets of master standards, Measurement time only 0.5 seconds, support sub-color difference display and Color bias analysis function.

$ 1009.00

Using 45 °/0 ° illumination, Repeatability Standard Deviation ≤ E * ab ≤ 0.08, can store 1500 sets of data, support a variety of Color difference formulas and four Available Light Sources to meet different measurement needs.

$ 501.00

Adopt Φ 4mm measurement aperture and full Light spectrum LED Illuminant, chromatic value Repeatability Delta E * ab 0.05, support cloud color database and a variety of Color difference formula calculation, portable design with dust cover and long battery life.

$ 538.00

Adopt 8 °/d illumination mode and Φ 4mm measurement diaMeter, chromatic value Repeatability Delta E * ab within 0.1, with Automatic calibration and moving Color Chart database function, support a variety of Color difference formula and Illuminant simulation.

$ 344.00

Adopt 8mm measurement diaMeter, Repeatability Delta E * ab < 0.05, equipped with TFT true color display, support a variety of Measurement light sources and Color difference formula, suitable for a variety of material surface color detection.

$ 1042.00

Equipped with eight Illuminants and three measurement diaMeters, the repeability accuracy reaches 0.05, supports a variety of Color difference formulas and display modes, built-in whiteboard automatic correction, suitable for irregular surface and small area measurement.

$ 1687.00

Adopt 45/0 illumination light receiving system, 8mm measurement aperture, support single and average Measurement mode, Repeatability Standard Deviation ≤ E * within 0.1, can carry out color difference contrast analysis and color quality control.

$ 307.00

Measurement paraMeters can be continuously printed without connecting to a computer, and a variety of color difference Meter models are supported, which is convenient for on-site data storage and recording.

$ 186.00

Featuring a 3.5-inch touchscreen for easy operation, it offers a measurement accuracy of 0.01 and a repeatability of ΔE*ab ≤ 0.03. Equipped with multiple built-in color cards for fast matching, it supports various color difference formulas and cloud-based data sharing.

$ 231.00

Using thermal printing technology, it is designed for use with testing instruments. It can directly connect the color difference Meter and Glossmeter to achieve real-time output of measurement data and report generation.

$ 220.00

Adopt D/8 lighting system and Φ 8mm measurement diaMeter, Inter-instrument Agreement Delta E * 00 < 0.2, equipped with multi-function smart buttons and wireless connection function, support a variety of Color difference formula and chroma index measurement.

$ 312.00

Special design container to ensure measurement conformity, suitable for color scheme, suitable for fine powder particle measurement, effectively avoid the influence of powder tightness and surface Smoothness.

$ 220.00

Adopt 0/d illumination geometry, Repeatability Delta E ≤ 0.2, equipped with 7-inch touchscreen, support data storage and a variety of color systems, suitable for reflection color measurement.

$ 2268.00

The 14mm large diaMeter design is suitable for texture and particle surface measurement, using 8/d Optical inspection geometry to ensure accurate data, Repeatability Standard Deviation Delta E * ab ≤ 0.08, supports a variety of chroma space and Color difference formula.

$ 703.00

Equipped with eight Illuminant and eight Color difference formula, repeability accuracy of 0.05, support three display modes and 8mm general measurement aperture, built-in whiteboard automatic correction, suitable for a variety of materials Color measurement.

$ 1493.00

Articles

The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Gloss meter measures the surface brightness of packaging film.
This article introduces the principle and method of using a gloss meter to measure the surface glossiness of packaging films. The gloss meter quantifies the specular reflection capability of a surface in gloss units by measuring the ratio of reflected light from the sample to that from a standard plate.
Colorimeter controls batch color difference in plastic and rubber films.
This article primarily discusses how to use a colorimeter to control color differences in the production of plastic and rubber films. It explains the working principle of the colorimeter, which involves converting colors into numerical values represented by L, a, and b values, and then calculating the color difference.
Colorimeter evaluates the change in yellowing index of transparent resin.
This article introduces how to use a colorimeter to measure the yellowing index changes in transparent resin. Transparent resin can turn yellow over time or due to environmental influences, and the yellowing index can quantify the degree of color change.
Gloss meter measures the gloss consistency of resin coating film surfaces.
This article introduces how to use a gloss meter to measure the gloss consistency of resin coating film surfaces.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
Reflectometer for measuring the hiding power of colored paint coatings
This article introduces the method of using a reflectometer to measure the hiding power of colored paint coatings. Hiding power refers to the ability of a coating to conceal differences in the underlying color. Traditional methods relying on visual judgment are prone to subjective influences, while instrumental measurement offers greater objectivity and accuracy.
Application of Gloss Meter in Gloss Measurement of Varnish Coatings
A gloss meter is used to measure the gloss of varnish coatings by detecting surface-reflected light to quantitatively assess the appearance of the coating. The measurement is based on the principle of specular reflection of light, commonly employing angles such as 20°, 60°, and 85° to correspond to different gloss ranges, and follows standard formulas for calculation.
Glossmeter 75-degree angle measurement for paper gloss
This article introduces the principle and method of measuring paper gloss using a 75-degree specular gloss meter. Gloss is defined as the ratio of the light reflected from the paper surface to that reflected from a standard reference plate, with the 75-degree angle commonly used for measuring medium to high gloss papers.
Application of Colorimeters in Color Management for Packaging and Printing
This article mainly discusses the application of colorimeters in color management for packaging and printing. A colorimeter is an instrument used to measure color, capable of converting colors into numerical values, such as representing them with L*a*b* values.
Multi-angle colorimeter detects color changes in pearlescent coatings.
Pearlescent coatings contain special flake pigments that produce color effects that vary with the viewing angle, known as "goniochromism." Traditional single-angle measurements struggle to accurately capture this characteristic.
Three-angle gloss meter for evaluating coatings with different gloss levels
Glossiness is a key indicator for evaluating the optical properties of a surface, defined as the ratio of the reflected luminous flux to the incident luminous flux, typically expressed as a percentage or in gloss units.
Method for measuring the gloss of ink surfaces using a gloss meter
This article introduces the method of measuring the surface gloss of ink using a gloss meter. Gloss is a key indicator of the visual quality of ink, and the instrument quantifies gloss by measuring reflected light at specific angles.
Application of Colorimeters in Controlling Color Differences in Paint Batches
This article introduces the role of colorimeters in controlling color consistency in paint production. Since human judgment of color is easily influenced by lighting and subjective factors, colorimeters quantify color differences in the CIELAB color space by measuring spectral data, providing an objective basis for production.
The use of a gloss meter in evaluating the surface gloss of printing paper and art paper.
Gloss meters quantify paper gloss by measuring surface reflected light, with 20°, 60°, and 85° angles commonly used for high, medium, and low gloss surfaces, respectively. The gloss characteristics of printing paper and art paper differ, so the appropriate measurement angle should be selected based on the estimated gloss level.