Environmental Chamber

Environmental test chambers simulate natural environmental conditions through temperature and humidity control systems to test the tolerance of materials under specific environments. The principle involves heating and cooling elements working in conjunction with humidification and dehumidification devices to cyclically adjust the climatic parameters inside the chamber. Their purpose is to verify the weather resistance of products, and they are used in industrial quality inspection processes such as aging tests for electronic components and observation of coating curing.
Selection
When selecting an environmental test chamber, considerations should include the temperature range and fluctuation, humidity control accuracy, and chamber volume matching the sample dimensions. Attention should be paid to compressor performance to ensure long-term operational stability, and the inner chamber material must be corrosion-resistant. Reserve sensor interfaces for easy expansion of functions, compare energy consumption indicators to control operating costs, and confirm after-sales response speed to ensure maintenance efficiency.

Instruments

Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, equipped with independent temperature limit alarm system, support multi-stage programmable control, easy to automate the operation of complex test process.

$ 5110.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with 100 sets of programmable control, support color Touchscreen operation and remote monitoring function, built-in multiple Safety protection system.

$ 16459.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, equipped with programmable Touchscreen controller, supports multi-stage program control and real-time data monitoring to ensure stable and reliable testing process.

$ 6983.00

Temperature range -60~ 150 ℃ and Humidity control 30~ 95% R.H., equipped with fluorine-free environmental protection refrigeration system; color Touchscreen supports multi-stage programming, with independent alarm and multiple Safety protection functions.

$ 17545.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control and independent temperature limit alarm system, support data export function.

$ 14388.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, with multi-stage programmable control function, support 100 sets of program settings, equipped with independent temperature limit alarm system to ensure safe operation.

$ 6194.00

Using fluorine-free environmental protection refrigerant and imported Compressor, Temperature range -20~ 150 ℃, humidity control 30~ 95% R.H., with independent temperature limit alarm and multiple Safety protection functions, support multi-stage programmable control.

$ 4138.00

Using fluorine-free environmental protection refrigerant and imported Compressor, temperature control accuracy +/- 0.5 ℃, Humidity deviation +/- 3% RH, with multi-stage programmable control and multiple Safety protection functions.

$ 6194.00

Using non-fluorine environmental protection refrigerant and imported Compressor, Temperature Uniformity +/- 2 ℃, equipped with independent temperature limit alarm system and multi-function programmable controller, support data export and remote monitoring function.

$ 8857.00

Using fluorine-free environmental protection refrigerant and imported Compressor, Temperature range -40~ 130 ℃, uniformity +/- 2 ℃, with 120 sets of programming and multiple Safety protection systems, support data communication and real-time monitoring.

$ 5208.00

Temperature range -40~ 130 ℃, Temperature Uniformity +/- 2 ℃, using fluorine-free environmental protection refrigerant and imported Compressor, with 120 groups of programmable control and independent temperature limit alarm system, support Interface for easy monitoring.

$ 6292.00

Temperature range -40~ 130 ℃ and uniformity +/- 2 ℃, using fluorine-free environmental protection refrigeration system, equipped with multi-stage programmable control and independent temperature limit alarm function to ensure the safety and stability of the experimental process.

$ 5405.00

With microcomputer programming control, can independently set the temperature Illumrination degree, light intensity 0~ 12000LX adjustable, Temperature Fluctuation +/- 0.5 ℃, support power-off memory and internal dehumidification function to ensure a stable environment.

$ 1705.00

Unique air duct circulation system is used to ensure that the wind is uniform and does not hurt the seedlings, supports 30-stage temperature and Humidity light programmable control, temperature fluctuation +/- 0.5 ℃, can simulate day and night temperature changes and multi-directional Illuminant environment.

$ 1655.00

Adopt imported Compressor and environmental protection refrigerant, temperature control accuracy +/- 0.5 ℃, equipped with independent temperature limit alarm system and multi-function programmable controller, support data export and real-time monitoring function.

$ 5405.00