Temperature-regulated water Bath

The constant-temperature water bath heats the liquid in the tank using an electric heating element and maintains a constant water temperature with the help of a thermostat. It is used for laboratory operations such as constant-temperature heating of samples, reagent dissolution, and reaction incubation. It is commonly employed in chemical analysis, biological cultivation, and other scenarios requiring a stable temperature environment.
Selection
When selecting, consider whether the temperature range and accuracy meet the experimental requirements, check the corrosion resistance of the inner tank material, and confirm that the capacity matches the sample size. Pay attention to the heating speed and temperature uniformity, and inspect safety protection features such as dry-burn protection. Choose between standard or circulating pump models based on the frequency of use.

Terms

Instruments

Water Bath and water Bath are integrated to achieve dual-use, using one-time stamping stainless steel liner for easy cleaning, temperature control accuracy +/- 0.3 ℃, equipped with water shortage and air burning and independent temperature limit safety system to ensure safe operation.

$ 562.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Water Bath and sink as a whole, using a stamping forming stainless steel liner, Temperature range RT + 5~ 99 ℃, temperature fluctuation +/- 0.3 ℃, with water shortage and independent temperature limit alarm function.

$ 493.00

With water Bath thermostatic oscillation and low temperature refrigeration dual functions, thermostatic range 0-100 ℃, temperature accuracy +/- 0.5 ℃, support reciprocating oscillation and digital constant speed operation, suitable for a variety of sample fostering needs.

$ 1027.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 6 samples processed simultaneously.

$ 620.00

With dual functions of constant temperature water Bath and magnetic Stir, temperature control accuracy up to +/- 0.5 ℃, Stir speed 0~ 1500rpm, stainless steel studio corrosion resistance, support 4 × 1000ml Stir, safe and easy operation.

$ 522.00

Synchronized processing of 12-bit samples, temperature control accuracy of +/- 1 ℃, circular water Bath heating and independent air path adjustment. Each air needle channel can be switched on and off separately, 316 stainless steel material is corrosion resistant, suitable for a variety of testtube specifications, supports timing and over-temperature alarm functions.

$ 871.00

The adapter adopts stainless steel sample Chamber removable cleaning, the temperature control accuracy of water Bath jacket reaches 0.1 ℃, the sample volume is only 2-16 ml, and the Measurement range covers 2-26600000MPas/cp.

$ 2300.00

It has the function of water shortage and air burning and independent temperature limiting system, temperature control accuracy +/- 0.3 ℃, adopts one-time stamping forming stainless steel liner, supports internal and external circulation and timing operation.

$ 459.00

Water Bath, water temperature box and boiling disinfection box three functions, Temperature range from room temperature to 100 ℃, Tank size 42 * 18 * 20cm, to meet a variety of experimental heating and disinfection needs.

$ 180.00

Temperature control accuracy of +/- 0.5 ℃, temperature resolution of 0.1 ℃, equipped with a built-in circulating water pump to output thermostatic water flow, stainless steel structure to ensure durability and easy cleaning.

$ 367.00

Adopt stainless steel liner and microcomputer intelligent temperature control system, Temperature Fluctuation +/- 0.2 ℃, resolution 0.1 ℃, with over-temperature water cut-off alarm function, built-in circulating water pump can output thermostatic water flow.

$ 622.00

Temperature control accuracy of +/- 0.5 ℃, temperature resolution of 0.1 ℃, equipped with built-in circulating water pump can output thermostatic water flow, support timing function to ensure experimental stability.

$ 214.00

Temperature range covers -40 to 100 ℃, Temperature Fluctuation accuracy to +/- 0.05 ℃, resolution up to 0.01 ℃, and supports internal and external double cycle mode to meet the needs of various experiments inside and outside the tank.

$ 1285.00

Articles

Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.
Xenon lamp aging test chamber for testing film weather resistance.
This article introduces how a xenon lamp weathering test chamber tests the weatherability of films. It uses a xenon lamp to simulate sunlight and controls conditions such as temperature and humidity to accelerate the aging process of the film, thereby evaluating its performance changes in outdoor environments.
Heating coating machine is used for the doctor-blade coating of gel electrolyte films in zinc-ion batteries.
This article introduces the blade coating process for preparing gel electrolyte films for zinc-ion batteries using a heated coating mechanism. By controlling parameters such as temperature, coating speed, and gap height, this method enables the fabrication of films with uniform thickness and smooth surfaces.
Application of Vacuum Heating Integrated Coating Machine in the Preparation of High-Temperature Curing Coating Samples
This article introduces the application of the vacuum heating integrated film coater in the preparation of samples for high-temperature curing coatings. The equipment reduces bubbles in the coating by creating a vacuum environment and integrates programmable heating and curing functions, enabling precise temperature control to promote the chemical cross-linking of the coating and form a uniform film.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
Method for measuring ink viscosity with a rotational viscometer
A rotational viscometer measures viscosity by detecting the torque experienced by the rotor as it rotates in the ink, with the calculation formula being η = K × (T/ω). Before measurement, it is necessary to select an appropriate rotor, control the temperature, and calibrate the instrument.
Constant Temperature Water Bath Controls the Temperature Sensitivity of Resin Viscosity
The constant temperature water bath can provide a stable temperature environment for studying the characteristics of resin viscosity as it changes with temperature.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
Salt spray test chamber evaluates the protective performance of powder coatings
The salt spray test chamber accelerates the evaluation of the corrosion resistance of powder coatings by simulating a salty and humid environment. The test is based on electrochemical principles, where salt spray penetrates coating defects and initiates corrosion of the metal substrate. During operation, parameters such as temperature and sedimentation rate must be strictly controlled, and standards such as ISO and ASTM must be followed.
Application of Constant Temperature and Humidity Chambers in the Electronics Industry
A constant temperature and humidity chamber is a device capable of precisely controlling temperature and humidity, used to simulate various environmental conditions that electronic products may encounter. In the electronics industry, it is primarily employed to test the reliability of components, finished products, and processes, such as evaluating material aging or performance changes through high-temperature and high-humidity tests.