Digital Magnetic Stirrer with Speed Control

The digital display magnetic stirrer drives the rotation of the magnetic rotor inside the container through the rotation of the bottom magnet to achieve liquid mixing. The digital display of rotation speed facilitates monitoring. It is used in laboratory settings for sample stirring, dissolution reactions, and other applications to ensure uniform mixing.
Selection
When selecting, consider that the container material must be non-magnetic, the speed range should match the viscosity of the sample, the heating function should be determined based on temperature requirements, the stirring capacity should correspond to the scale of the experiment, and the operation interface should be intuitive and easy to use.

Terms

Instruments

Heating power 800W, speed range 0-2600 rpm, support vacuum reaction and pressure reaction for a long time stirring, with durable magnetic steel and PTFE stirrer.

$ 209.00

With temperature and rotational speed dual digital display function, temperature control accuracy of +/- 1 ℃, using PID self-tuning and thyristor control, Max. stirring Capacity 2000mL, heating power 500W, Pottery and porcelain coated panels are resistant to corrosion and high temperature.

$ 667.00

Using three-phase brushless DC motor to achieve 50-1500rpm stable speed regulation, temperature control accuracy +/- 1 ℃ and with temperature protection function, soft start design to prevent stirrer beating, suitable for long-term unmanned operation.

$ 424.00

Single chip digital control technology, with heating plate and liquid temperature double automatic temperature control function, temperature control accuracy +/- 1 ℃, Max.stirring Capacity 5L, support 0-250 minutes timing and 1500rpm Rotation speed adjustment.

$ 298.00

Driven by three-phase brushless DC motor, with large torque and strong magnetic force, Max. stirring Capacity 50L, stirring speed 60~ 1400rpm, digital display Rotation speed is clear and intuitive, suitable for large-capacity stirring needs.

$ 545.00

Driven by three-phase brushless DC motor, Rotation speed 50-1500rpm can be adjusted smoothly, temperature control accuracy +/- 0.5 ℃, with soft start anti-hopper and temperature protection functions, suitable for long-term unattended operation.

$ 424.00

Rotation speed is stable with brushless DC motor, torque is 73.5mN · M, magnetic force is especially strong, suitable for large capacity stirring, Max. stirring Capacity 20L, Speed range 60~ 2000rpm.

$ 323.00

Driven by three-phase brushless DC motor, with large torque and strong magnetic force, Max. stirring Capacity 50L, stirring speed 60~ 1400rpm, suitable for large-capacity stirring, and equipped with digital display Rotation speed.

$ 520.00

With 0~ 2400rpm stepless speed regulation function, Temperature range RT +~ 100 ℃, digital temperature control system to ensure that the solution stirring process is stable and accurate, suitable for small volume sample experimental operation.

$ 149.00

With a wide range of 0~ 2500rpm speed regulation, low-speed stable high-speed strong; temperature control accuracy of +/- 1 ℃, using PID self-tuning function; 30 ° inclined surface operation panel in line with ergonomic perspective; Pottery and porcelain coating heating surface resistant to strong acid and alkali.

$ 603.00

With six synchronous stirring function, Max. stirring Capacity up to 6000mL, Speed range 0-2400rpm stepless adjustable, using digital temperature control system, support room temperature to 100 ℃ accurate temperature control, suitable for small volume sample experiments.

$ 344.00

Quadruple Synchronous Stir Design, Temperature range RT +~ 100 ℃, using digital electronic temperature control technology, heating power 150W * 2, stirring speed 0~ 2000rpm, DC motor running without noise vibration.

$ 243.00

With electric and magnetic dual stirring function, Temperature range to 100 ℃, Max. stirring Capacity 1000mL, suitable for small volume sample precise and stable stirring.

$ 180.00

Using series micro motor and multi-stage Non-metallic gear drive, Max. Torque 195N.cm, Speed range 50-1500rpm, with numerical control touch stepless speed regulation and digital display function, stable operation and low noise.

$ 569.00

Magnetic field drive technology implementation of liquid mixing, Speed range 0-1800rpm adjustable, maximum stirring capacity 2000ml, equipped with digital timing function, support charging and easy to move operation.

$ 115.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Selection of disperser speed range and matching of dispersing disc form with container
This article discusses the technical points in the selection of a disperser, including the speed range, the form of the dispersion disc, and the matching with the container.
Effect of Spin Coater Rotation Speed and Acceleration Settings on Photoresist Coating Uniformity
This article primarily explores how the settings of rotational speed and acceleration in a spin coater affect the uniformity of photoresist coating.
Process of Three-Roll Mill for Handling High-Viscosity Inks
This article introduces the process of using a three-roll mill to handle high-viscosity inks. It first explains that the equipment utilizes three rollers rotating at different speeds to grind materials through shearing and squeezing actions, making it suitable for high-viscosity systems.
Stormer viscometer measures the KU viscosity of latex paint
This article introduces the method of measuring the KU viscosity of latex paint using a Stormer viscometer. The viscometer measures the load required to maintain a fixed rotational speed through the rotation of its paddle, thereby calculating the KU value, which is related to the application and storage properties of the coating.
Rotational Viscometer vs. Stormer Viscometer: How to Choose the Right Instrument Based on Coating Type
The rotational viscometer measures viscosity by detecting rotor torque and can analyze rheological properties at different shear rates, making it suitable for research and precise measurements. The Stormer viscometer uses the load at a fixed rotational speed to determine the KU value, simulating construction conditions, and is commonly used for rapid on-site evaluation of coating application performance.
Application of Stormer Viscometer KU Value in Coating Viscosity Control
This article introduces the application of KU values measured by the Stormer viscometer in the coatings industry. The KU value reflects the viscosity of coatings by measuring the torque at a specific rotational speed, with higher numbers indicating greater viscosity.
If the standard disintegrator procedure for fiber dissociation is not done correctly, the first step of paper strength testing is already compromised.
Fiber disintegration is the first step in paper strength testing. If the operation is not standardized, such as inaccurate concentration, excessive time, or incorrect rotational speed, it can lead to fiber breakage or uneven dispersion, resulting in inaccurate strength data for the prepared hand sheets.