Using the magnetic induction method, the measurement range is 0~2000 μm, with an error of ±5%, a resolution of 0.1 μm. It supports separate probes and low-voltage alerts, and is suitable for various types of coatings.
Adopting the principle of magnetic Induction Thickness Measurement range 0~ 1250 microns, suitable for LEEB242 models, can be connected to the printer output data, suitable for nonmagnetic Coating thickness detection on magnetic metal substrates.
Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.
Using magnetic Induction Measuring method, range 0~ 5mm, error +/- 5%, can measure a variety of non-ferrous magnetic coatings, suitable for different curvature substrate surface.
Measurement range 0-1000 microns with dual-function Probe design, wear-resistant Ruby Probe and V-groove structure, support for automatic substrate identification and zero point Adjustment.
Using high-speed ADC data collection, resolution up to 1μm, can simultaneously measure the thickness of multi-layer coatings or coatings plus substrates, with gain automatic switching and estimated thickness setting function, Measurement range 13~ 1000μm (epoxy resin coating).
Adopt magnetic Induction principle measurement 0-10mm thickness range, resolution up to 0.1μm, Probe wear-resistant more than 500,000 times, suitable for -10-50 ℃ environment, error range +/- 3%, stable and fast test.
Using magnetic Induction principle, Measurement range of 0-10000 μ m, support one and two point calibrating, split structure design can adapt to a variety of Probe types, to meet different Coating thickness measurement needs.
Adopt magnetic Induction principle to measure 0-1250μm thickness, equipped with line Probe measurement groove and narrow area, support single point and two point calibrating, with automatic matrix recognition and undervoltage prompt function.
Using magnetic Induction and eddy Current principle simultaneous measurement composite coatings, Measurement range 0~ 1500μm, error +/- 1%, can display a single coating and zinc layer thickness, suitable for the accurate detection of ferrous and non-ferrous substrates.
Using magnetic principle, Coating thickness can be measured within 10 microns, Probe wear-resistant times more than 500,000 times, with single point, five point calibrate and Data storage function, suitable for inner hole or narrow position.
Adopt magnetic Induction principle measurement, thickness range 0~ 1000μm, error +/- 3%, with low voltage prompt function, support split Probe and customized range, adapt to different curvature matrix measurement needs.
Using magnetic Induction principle to automatically identify the substrate, Measurement range 0-5000μm, accuracy +/- 3%, Probe wear-resistant more than 500,000 times, suitable for a variety of harsh environments.
Using magnetic Induction and eddy Current dual principle, automatic identification of substrate type, Measurement range 0~ 6000 μm, accuracy +/- 3%, equipped with 30mm wear resistant Probe, can obtain more than 60 readings per minute, Protection Rating IP65.
Measurement range of 0~ 1250μm using magnetic Induction principle, with +/- 3% error accuracy and 0.1μm resolution, supports single continuous two Measurement mode, equipped with wear-resistant metal probe to ensure measurement Stability.