With a wide temperature measurement range of -50~ 480 ℃, the accuracy is +/- 1.5%, the Response Time is only 500ms, the object distance ratio is 12:1, suitable for fast non-contact measurement, lightweight and portable.
Imported Infrared Sensor, CO2 concentration recovery time ≤ 3 minutes, temperature recovery ≤ 8 minutes, equipped with HEPA high-efficiency Filter, with door temperature heating system and automatic wind speed adjustment function.
Using shortwave infrared technology, temperature range 200~ 2200 ℃, accuracy +/- 2%, with laser positioning, data retention and emissivity adjustable functions, Response Time 500ms, object distance ratio 80:1.
With 0-100% measurement range and 0.1 resolution, accuracy +/- 2%, support ultraviolet-visible infrared three-band light transmitance measurement, swirl/spin Sensor for multi-angle testing, portable design for easy field use.
Using Infrared Sensor to monitor CO2 concentration, not affected by Temperature Humidity, CO2 concentration recovered within 5 minutes after opening the door, Temperature Fluctuation +/- 0.2 ℃, equipped with Microbial Filter and door temperature heating system to prevent condensation pollution.
Using infrared Light spectrum measurement technology, the temperature measurement range covers -18 to 1150 ° C, the accuracy is +/- 2%, with 20:1 object distance ratio and 500ms fast Response, support Data storage and USB connection function.
Using vanadium oxidation uncooled infrared focal plane Detector, temperature resolution of 0.1 ℃, with 56 ° × 42.2 ° field of view and focus-free design, support center point temperature measurement and cold hot spot automatic tracking function.
Infrared CO2 Sensor control accuracy is stable, Temperature Fluctuation +/- 0.5 ℃, using double door structure and door temperature heating system, effectively prevent condensation and pollution, short recovery time.
Equipped with infrared CO2 sensor accuracy of 0.1%, Water-jacketed heating ensures temperature stability, built-in ultraviolet sterilization function effectively prevents pollution, supports programmed control and data recording.
Adopting a non-light infrared NDIR Sensor, with a range of 0~ 1000ppm, Response Time ≤ 15 seconds, supports a variety of signal output and remote transmission, and has overvoltage protection and automatic recovery functions.
Infrared CO2 Sensor to ensure accurate concentration control, Temperature Uniformity of +/- 0.3 ℃, with double door sealing and quick recovery function, effectively prevent condensation pollution, improve the Reliability of the experiment.
Non-contact measurement avoids contact with dangerous objects, Response Time 500ms Fast reading temperature, temperature range -32~ 550 ℃ covers a wide range of scenarios, compact structure and easy to operate.
Adopt non-light infrared NDIR Sensor, Response Time ≤ 15s, detection accuracy ≤ +/- 2%, support PPM,% VOL, mg/m ³ Unit switch, with overvoltage protection and automatic recovery function.
Using infrared CO2 sensor accuracy of +/- 0.1%, equipped with ultraviolet sterilization system and microbial Filter, circulating wind speed automatically adjusted, volume 150L, temperature recovery time ≤ 8 minutes.
Using Infrared CO2 Sensor, accuracy +/- 0.1%, Response Fast is not affected by Temperature Humidity; Equipped with UV Sterilization and Microbial Filter to effectively prevent pollution; Circulating fan speed is automatically adjusted to avoid sample volatilization.