Paint Film Pendulum (Persoz) Hardness Tester

The pendulum hardness tester for paint films evaluates hardness by swinging a pendulum on the surface of the paint film, based on the decay time or number of swings. The energy loss when the pendulum contacts the paint film reflects the material's resistance to deformation. It is used to test the hardness of coatings and inks after drying, guiding formula adjustments and process control.
Selection
When selecting, consider matching the measurement range to the sample hardness, confirm that the pendulum type complies with standards, and check the instrument's leveling adjustment function. Review the friction index of the pendulum axis and verify the validity of the calibration certificate. Choose an appropriate base according to the sample thickness and ensure that the environmental temperature and humidity are controllable.

Terms

Standards

Instruments

Konig and Persoz swing bars are used, Konig swing period is 1.4s, Persoz swing period is 1s, and the number of swing angles is automatically recorded, which is suitable for accurate determination of paint film Hardness.

$ 662.00

It can be equipped with 200 +/- 0.2g and 500g swing Rods, providing 1.4 +/- 0.02s and 1 +/- 0.001s swing cycles respectively, and accurately determines the film Hardness through damping time to adapt to different coating resilience and viscosity characteristics.

$ 538.00

Equipped with 200 +/- 0.2g and 500 +/- 0.1g two swing bars, can measure the film damping time, reflect the surface Hardness through swing attenuation, support different standard test requirements.

$ 590.00

Equipped with 200 +/- 0.2g Koenig pendulum and 500g platinum saz pendulum two configurations, the swing period is 1.4 +/- 0.02s and 1 +/- 0.001S, through the photoelectric system automatic measurement of film damping time, to meet the different standards of test requirements.

$ 751.00

Using Konig swing Rod, mass 200g, swing period 1.4 +/- 0.02s, can swing 250 +/- 10s on flat Glass, suitable for coating damping test, accurate measurement Hardness change.

$ 503.00

Adopting Koenig pendulum structure, the total mass is 200 +/- 0.2g, and the swing period is 1.4 +/- 0.02s. The coating Hardness is accurately measured by the swing attenuation time, and the number of swing angles is automatically recorded.

$ 525.00

The stepper motor is used to achieve fully automatic positioning, the electromagnetic system releases the swing Rod, the Persoz swing Rod cycle is 1 second, and the swing time on the flat Glass is 430 +/- 15 seconds. There are visual and acoustic signals at the end of the test.

$ 1058.00

Support Koenig and Persaz double pendulum automatic switching, steel ball diaMeter 5mm and 8mm, with electromagnetic release and electronic counting mechanism to ensure that the test is accurate and not affected by the environment.

$ 11520.00

The photoelectric counter is used to realize automatic counting, and the measurement is fast and accurate; the period of M-3 swing Rod is 0.625s, and the swing time on standard Glass is 440 +/- 6s; the horizontal mechanism is improved, and the scale can be moved horizontally to facilitate zero adjustment.

$ 451.00

Using the electromagnet cissing pendulum, it can measure the thickness of the test plate from 0.1mm to 5.5mm, and is equipped with two laser Probes to record data. The swing period is 0.625s.

$ 1445.00

Using stopwatch counting method, the length of the swing Rod is 500 +/- 1mm, and the total mass of the swing is 120 +/- 1g. The resistance to deformation is evaluated by measuring the ratio of the swing amplitude time on the film to the swing time on the Glass.

$ 251.00

Hand type easy to operate, load 1000g, standard 6B-6H pencil, suitable for film hardness testing, test temperature 23 +/- 2 ℃ and Humidity 50 +/- 5% environment.

$ 341.00

Using electromagnet cissing pendulum, equipped with two laser Probe to record data, the thickness range can be measured 0.1-5 mm, the organic Glass door cover reduces the influence of airflow, and the swing period is 1 second.

$ 1429.00

Using electromagnet cissing pendulum, equipped with two laser Probe recording data, can test 0.1mm to 5.5mm thickness test plate, swing period 1.4s, Organic Glass door cover to reduce the impact of airflow.

$ 1429.00

Using 500g swing Rod mass and 8mm steel ball diaMeter, automatic counting function can accurately measure coating surface Hardness, swing cycle of 1 second to achieve efficient testing.

$ 1655.00

Articles

The pendulum hardness tester tests the scratch resistance limit of varnish.
The pendulum hardness tester measures the hardness of varnish by observing the attenuation of the pendulum's swing on the coating surface, with faster attenuation indicating a softer coating. The scratch resistance of varnish depends not only on hardness but also on elasticity and toughness. Hardness testing sets the basic threshold for scratch resistance.
Use of pendulum hardness tester for paint film curing degree assessment in the laboratory.
The pendulum hardness tester evaluates the hardness of a paint film by measuring the decay time of a pendulum swinging on the surface of the film, where a longer time indicates a harder film and a higher degree of curing.
Pendulum hardness tester measures the damping hardness of powder coatings.
This article introduces the method of testing the damping hardness of powder coatings using a pendulum hardness tester. The test is based on the principle of energy attenuation, where the hardness is reflected by the time it takes for the amplitude of the pendulum to decay as it swings on the coating surface, with a longer time indicating a harder coating.
Pendulum hardness tester measures coating damping hardness.
This article explains how a pendulum hardness tester measures the damping hardness of coatings. The principle involves evaluating the hardness and elasticity of the coating based on the time it takes for the amplitude of a pendulum's swing to decay on the coating surface. A longer decay time indicates a harder coating.