ElectRode filling solution design, suitable for ammonia Gas sensing electRode maintenance, capacity 480mL, provide stable ion strength adjustment, ensure Measurement accuracy and ElectRode life.
Dedicated to Nitrate and Fluoro Boricacid Ion Composite ElectRode, 250ml Encasement, provides a stable ionic strength environment, ensuring ElectRode measurement accuracy and long-term Stability.
Dedicated to lead ion detection system, 250ml standard Encasement, ElectRode potential stability is ensured by adjusting ion strength, and measurement accuracy and Repeatability are improved.
ElectRode filling solution, suitable for ammonia Gas sensing electRode maintenance, capacity 480 ml, can effectively adjust the ionic strength, improve ElectRode Response Speed and Measurement accuracy.
Optimized for Ammonium Ion Composite ElectRode, 250ml Encasement meets the needs of routine use, improves ElectRode Response performance by adjusting the ionic strength, and is suitable for a variety of detection environments.
Adopt stepper motor to achieve stepless speed regulation of 1~ 500mm/min, equipped with 500N force value Measurement range and +/- 1% accuracy level, with overload protection and limit protection functions, stable and reliable operation.
Optimized for calcium ion detection, 250ml Encasement meets the needs of routine use, ensures ElectRode Response Stability by adjusting the ion strength, and improves the Reliability of detection data.
Specially designed for sodium ion detection, 250ml standard Encasement, ElectRode measurement accuracy is ensured by adjusting the ionic strength of the solution, suitable for a variety of water quality analysis scenarios.
Designed for potassium ion detection, 250ml standard Encasement can stabilize the ionic strength of the solution and ensure ElectRode Response performance, suitable for routine laboratory testing needs.
250Ml Encasement Specification, dedicated to fluoride ion detection, provides a stable ion strength environment, effectively guarantees ElectRode Measurement accuracy and Repeatability.
Using precision screw pair and servo motor drive, the test speed range is 1~ 500mm/min, the effective stroke is 800mm, with overload protection and limit protection functions, and the operation is stable and reliable.
Specially designed for fluoride ion detection, 250ml standard Encasement can effectively maintain the stability of solution ionic strength, ensure ElectRode Response performance, improve measurement Repeatability and accuracy.
Designed for fluoride ion detection, 250ml standard Encasement provides a stable ionic strength environment to ensure ElectRode measurement accuracy and Repeatability, suitable for a variety of water quality analysis scenarios.
ElectRode composite design, equipped with 60mL reference filling solution and calibrated solution, built-in BNC connector interface, support the use of ionic strength modifier, stable and reliable measurement.
Maximum load 50Kg, Test speed 10~ 60mm/min adjustable, using pointer sensing mode, effective Travel 0~ 360mm, suitable for vertical angle disbonding test.